Investigation in image quality and immediate patient safety using pre-dual-flow injection for low-contrast dose spectral pulmonary artery CT angiography

被引:0
|
作者
Xue, Liwei [1 ]
Zhong, Qing [2 ]
Xu, Nianjie [1 ]
Zheng, Yanping [1 ]
Liu, Yuanfen [3 ]
机构
[1] Fujian Med Univ, Dept Radiol, Union Hosp, 29 Xinquan Rd, Fuzhou 350001, Fujian, Peoples R China
[2] Fujian Med Univ, Dept Gastr Surg, Union Hosp, Fuzhou, Fujian, Peoples R China
[3] Fujian Med Univ, Dept Imaging, Union Hosp, Fuzhou, Fujian, Peoples R China
关键词
Pulmonary artery CT angiography; Pre -dual -flow injection; Safety; Image quality; ACUTE KIDNEY INJURY; COMPUTED-TOMOGRAPHY; RISK; SCANS;
D O I
10.1016/j.ejro.2024.100571
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The patient safety of iodine contrast-enhanced pulmonary artery CT angiography (CTPA) is widely concerned. This study aimed to investigate the image quality and immediate patient safety of spectral CTPA using a lower-contrast dose pre-dual-flow injection method. Methods: This retrospective study included 120 patients with suspected pulmonary embolisms who received spectral CTPA between February and December 2022. Patients were divided into normal contrast injection (Group A, n=60) and pre-dual-flow group (Group B, n=60). CT values of pulmonary arteries (PAs) at different levels, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), arteriovenous separation performance, and beam hardening artifact (BHA) index of two sets of images were measured or calculated. The subjective image quality and immediate patient safety were also scored using the three-point method. Results: Group B had a contrast dose reduction by 42.5 % (60 vs. 34.5 mL). Radiation exposure dose was not statistically different between the two groups (P>0.05). CT values of different-level PAs on group B images were higher than those on group A images (P<0.05). Group B images had higher SNR and CNR, better arteriovenous separation between PA trunk and pulmonary vein, and lower BHA index on soft tissue and PA (all P<0.05). For subjective evaluation of image quality, group B had a better score in beam hardening artifact (P<0.05). For immediate patient safety, the score in comfortability was statistically higher in group B, with P<0.05. Conclusions: Comparing with the normal injection method, pre-dual-flow spectral CTPA with a lower contrast dose injected results in better image quality and shows potential in patient-safety promotion.
引用
收藏
页数:7
相关论文
共 24 条
  • [21] Image quality of ultra-low-dose dual-source CT angiography using high-pitch spiral acquisition and iterative reconstruction in young children with congenital heart disease
    Zheng, Minwen
    Zhao, Hongliang
    Xu, Jian
    Wu, Yongjie
    Li, Jian
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (06) : 376 - 382
  • [22] Diagnostic Accuracy, Image Quality and Patient Comfort for Coronary CT Angiography Performed Using Iso-Osmolar versus Low-Osmolar Iodinated Contrast: A Prospective International Multicenter Randomized Controlled Trial
    Nakazato, Ryo
    Arsanjani, Reza
    Shalev, Aryeh
    Leipsic, Jonathon A.
    Gransar, Heidi
    Lin, Fay Y.
    Gomez, Millie
    Berman, Daniel S.
    Min, James K.
    ACADEMIC RADIOLOGY, 2016, 23 (06) : 743 - 751
  • [23] Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine
    Paul, Jean-Francois
    Amato, Aude
    Rohnean, Adela
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (03): : 651 - 657
  • [24] Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine
    Jean-François Paul
    Aude Amato
    Adela Rohnean
    The International Journal of Cardiovascular Imaging, 2013, 29 : 651 - 657