Severe Spontaneous Tilt of Scleral-Fixated Intraocular Lenses

被引:2
|
作者
Enright, Jennifer M. [1 ]
Purt, Boonkit [2 ,3 ,4 ]
Bruck, Brent [1 ]
Shah, Parth [1 ]
Eton, Emily [2 ]
Rezaei, Sina [2 ]
Armenti, Stephen [5 ]
Patel, Kishan G. [6 ]
Liu, James [1 ]
Verkade, Angela [2 ]
Hamad, Abdualrahman [7 ]
Wubben, Thomas J. [2 ]
Sheybani, Arsham [1 ]
Crandall, David [7 ]
Tannen, Bradford L. [2 ]
Comer, Grant M. [2 ]
Mian, Shahzad [2 ]
Nallasamy, Nambi [2 ]
机构
[1] Washington Univ St Louis, Sch Med, John F Hardesty MD Dept Ophthalmol & Visual Sci, St Louis, MO USA
[2] Univ Michigan, Kellogg Eye Ctr, Dept Ophthalmol & Visual Sci, 1000 Wall St, Ann Arbor, MI 48105 USA
[3] VA Ann Arbor Hlth Care Syst, Ann Arbor, MI USA
[4] Uniformed Serv Univ Hlth Sci, Bethesda, MD USA
[5] Univ Penn Hlth Syst, Scheie Eye Inst, Dept Ophthalmol, Penn Med, Philadelphia, PA USA
[6] Univ Texas Southwestern Med Ctr, Dept Ophthalmol, Dallas, TX USA
[7] Henry Ford Hlth Syst, Dept Ophthalmol, Detroit, MI USA
关键词
CLINICAL-OUTCOMES;
D O I
10.1016/j.ajo.2024.02.006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To report and evaluate a multicenter series of 18 cases of severe, spontaneous IOL tilt involving the flanged intrascleral haptic fixation technique (FISHF). center dot DESIGN: Clinical study with historical controls. center dot METHODS: We report a cross-sectional study of 46 FISHF cases using the CT Lucia 602 IOL at a single academic center over a period of 24 weeks to determine the incidence of severe rotisserie -style rotational tilt. These rates were then compared with the same time -frame the prior year to help determine if this is a new phenomenon. Additional cases of severe tilt were solicited from another 4 academic centers. center dot RESULTS: Among 46 FISHF cases at a single center, 5 developed severe tilt. No clear pattern in surgical technique, ocular history, or ocular anatomy was evident in these cases compared with controls, although the involved IOLs clustered within a narrow diopter range, indicative of a batch effect. In the same 24 -week interval the year before, 33 FISHF cases were performed, none of which exhibited severe rotational tilt. In our multicenter dataset, 18 cases of tilt were identified. Surgeons included fellow and early -career physicians as well as surgeons with multiple years of experience with the Yamane technique. A variety of surgical approaches for FISHF were represented. In at least 8 of the cases, haptic rotation and/or dehiscence at the optic-haptic junction were documented. center dot CONCLUSIONS: The identification of haptic rotation and dehiscence intraoperatively in several cases may reflect a new stability issue involving the optic-haptic junction. (Am J Ophthalmol 2024;262: 206-212. (c) 2024 Published by Elsevier Inc.)
引用
收藏
页码:206 / 212
页数:7
相关论文
共 50 条
  • [31] Alternative technique for implantation of a scleral-fixated intraocular lens
    Peden, Marc
    Adams, Serrhel
    Huffman, Bryan
    Kaushal, Shalesh
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02): : 226 - 229
  • [32] Sutureless scleral-fixated posterior chamber intraocular lens
    Kumar, Dhivya Ashok
    Agarwal, Amar
    Jacob, Soosan
    Prakash, Gaurav
    Agarwal, Athiya
    Gabor, Scharioth G. B.
    Prasad, Som
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11): : 2089 - 2090
  • [33] Outcomes and complications in scleral-fixated intraocular lens implantations
    Ka Wai Kam
    Yu Fung Anthony Chan
    Marco Yu
    Mary Ho
    Alvin L. Young
    International Ophthalmology, 2020, 40 : 2969 - 2977
  • [34] Instruments for ab externo scleral-fixated intraocular lens
    Meskin, Seth W.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12): : 2212 - 2212
  • [35] Scleral-fixated intraocular lenses with Z-suture technique for lens subluxation associated with spherophakia
    Bocque, Catheline
    Januschowski, Kai
    OPHTHALMOLOGE, 2020, 117 (03): : 267 - 269
  • [36] Iris capture and reverse pupillary block in eyes with scleral-fixated posterior chamber intraocular lenses
    Scharioth, Gabor B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (05): : 673 - 673
  • [37] Long term stability of scleral-fixated intraocular lenses secured with a cow-hitch knot
    Girgis, Shenouda
    Lee, Lawrence
    Ting, Eugene R.
    Fraenkel, Allison
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 50 (08): : 899 - 900
  • [38] VISUAL OUTCOMES AND COMPLICATIONS OF SCLERAL-FIXATED POSTERIOR CHAMBERINTRAOCULAR LENSES
    McAllister, Andrew
    Hirst, Lawrence
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 : 14 - 14
  • [39] Scleral fixated intraocular lenses - An angiographic study
    Lanzetta, P
    Menchini, U
    Virgili, G
    Crovato, S
    Rapizzi, E
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1998, 18 (06): : 515 - 520
  • [40] VISUAL OUTCOME IN SCLERAL FIXATED INTRAOCULAR LENSES
    Saxena, Devendra
    Patel, Chaitali
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (55): : 3716 - +