Severe Spontaneous Tilt of Scleral-Fixated Intraocular Lenses

被引:2
|
作者
Enright, Jennifer M. [1 ]
Purt, Boonkit [2 ,3 ,4 ]
Bruck, Brent [1 ]
Shah, Parth [1 ]
Eton, Emily [2 ]
Rezaei, Sina [2 ]
Armenti, Stephen [5 ]
Patel, Kishan G. [6 ]
Liu, James [1 ]
Verkade, Angela [2 ]
Hamad, Abdualrahman [7 ]
Wubben, Thomas J. [2 ]
Sheybani, Arsham [1 ]
Crandall, David [7 ]
Tannen, Bradford L. [2 ]
Comer, Grant M. [2 ]
Mian, Shahzad [2 ]
Nallasamy, Nambi [2 ]
机构
[1] Washington Univ St Louis, Sch Med, John F Hardesty MD Dept Ophthalmol & Visual Sci, St Louis, MO USA
[2] Univ Michigan, Kellogg Eye Ctr, Dept Ophthalmol & Visual Sci, 1000 Wall St, Ann Arbor, MI 48105 USA
[3] VA Ann Arbor Hlth Care Syst, Ann Arbor, MI USA
[4] Uniformed Serv Univ Hlth Sci, Bethesda, MD USA
[5] Univ Penn Hlth Syst, Scheie Eye Inst, Dept Ophthalmol, Penn Med, Philadelphia, PA USA
[6] Univ Texas Southwestern Med Ctr, Dept Ophthalmol, Dallas, TX USA
[7] Henry Ford Hlth Syst, Dept Ophthalmol, Detroit, MI USA
关键词
CLINICAL-OUTCOMES;
D O I
10.1016/j.ajo.2024.02.006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To report and evaluate a multicenter series of 18 cases of severe, spontaneous IOL tilt involving the flanged intrascleral haptic fixation technique (FISHF). center dot DESIGN: Clinical study with historical controls. center dot METHODS: We report a cross-sectional study of 46 FISHF cases using the CT Lucia 602 IOL at a single academic center over a period of 24 weeks to determine the incidence of severe rotisserie -style rotational tilt. These rates were then compared with the same time -frame the prior year to help determine if this is a new phenomenon. Additional cases of severe tilt were solicited from another 4 academic centers. center dot RESULTS: Among 46 FISHF cases at a single center, 5 developed severe tilt. No clear pattern in surgical technique, ocular history, or ocular anatomy was evident in these cases compared with controls, although the involved IOLs clustered within a narrow diopter range, indicative of a batch effect. In the same 24 -week interval the year before, 33 FISHF cases were performed, none of which exhibited severe rotational tilt. In our multicenter dataset, 18 cases of tilt were identified. Surgeons included fellow and early -career physicians as well as surgeons with multiple years of experience with the Yamane technique. A variety of surgical approaches for FISHF were represented. In at least 8 of the cases, haptic rotation and/or dehiscence at the optic-haptic junction were documented. center dot CONCLUSIONS: The identification of haptic rotation and dehiscence intraoperatively in several cases may reflect a new stability issue involving the optic-haptic junction. (Am J Ophthalmol 2024;262: 206-212. (c) 2024 Published by Elsevier Inc.)
引用
收藏
页码:206 / 212
页数:7
相关论文
共 50 条
  • [1] Severe unprovoked post-operative tilt of scleral-fixated intraocular lenses
    Enright, Jennifer
    Verkade, Angela
    Wubben, Thomas
    Tannen, Bradford
    Mian, Shahzad
    Nallasamy, Nambi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [2] SCLERAL-FIXATED INTRAOCULAR LENSES
    MALBRAN, ES
    MALBRAN, E
    ARANGUREN, AN
    ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (10) : 1347 - 1348
  • [3] Bilateral spontaneous subluxation of scleral-fixated intraocular lenses
    Assia, EI
    Nemet, A
    Sachs, D
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12): : 2214 - 2216
  • [4] SCLERAL-FIXATED INTRAOCULAR LENSES - REPLY
    SHIN, DH
    HU, BV
    HONG, YJ
    GIBBS, KA
    ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (10) : 1348 - 1348
  • [5] Complications of Scleral-Fixated Intraocular Lenses
    Davies, Emma C.
    Pineda, Roberto, II
    SEMINARS IN OPHTHALMOLOGY, 2018, 33 (01) : 23 - 28
  • [6] Secondary implantation of scleral-fixated intraocular lenses
    Uthoff, D
    Teichmann, KD
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (07): : 945 - 950
  • [7] IMPLANTATION OF SCLERAL-FIXATED POSTERIOR CHAMBER INTRAOCULAR LENSES
    SMIDDY, WE
    SAWUSCH, MR
    OBRIEN, TP
    SCOTT, DR
    HUANG, SS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (06): : 691 - 696
  • [8] Scleral-fixated posterior chamber intraocular lenses in nonvitrectomised eyes
    Y F Yang
    C Bunce
    J K G Dart
    R L Johnston
    D G Charteris
    Eye, 2006, 20 : 64 - 70
  • [9] Complications of sutured versus sutureless scleral-fixated intraocular lenses
    Gupta, Parul Chawla
    Ram, Jagat
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (05): : 806 - 806
  • [10] Scleral-Fixated Intraocular Lenses: An Update on the Current Surgical Approaches
    Joshi, Malav
    Walsh, Mark K.
    CURRENT SURGERY REPORTS, 2015, 3 (05):