Dear Laparoscopic Surgeon: a Word of Caution with the Use of Glutaraldehyde!!!

被引:0
|
作者
Mukherjee, Sampreeti [1 ]
Goswami, Chandramouli [1 ]
Dhua, Anjan Kumar [1 ]
Goel, Prabudh [1 ]
机构
[1] All India Inst Med Sci, Dept Paediat Surg, New Delhi 110029, India
关键词
Glutaraldehyde; Cidex; Laparoscopy; Bowel injury; High-level disinfection;
D O I
10.1007/s12262-024-04107-9
中图分类号
R61 [外科手术学];
学科分类号
摘要
Glutaraldehyde is used in the hospital setup for high-level disinfection of heat-sensitive instruments like endoscopes, bronchoscopes, and arthroscopes. Notwithstanding the occupational hazards, glutaraldehyde is still being used in the third-world countries to facilitate rapid turnover in between cases. The adverse effects of glutaraldehyde spill inside the peritoneal domain have been reported sparingly and highlighted only exceptionally. The authors have shared their experience with inadvertent intra-peritoneal glutaraldehyde-spill during uneventful laparoscopic surgery in a child. The blind spot during laparoscopy, preventive safeguards, and therapeutic outcomes have been highlighted.
引用
收藏
页码:191 / 195
页数:5
相关论文
共 50 条