A rare case of taper junction corrosion in semi-constrained total knee arthroplasty

被引:0
|
作者
Ekweariri, Nnadozie [1 ]
White, Ryan [1 ]
Brown, Nicholas [1 ]
Schmitt, Daniel [1 ]
机构
[1] Loyola Univ, Med Ctr, Dept Orthopaed Surg, 2160 South 1st Ave, Maywood, IL 60153 USA
来源
KNEE | 2024年 / 48卷
关键词
Total knee arthroplasty; Revision; Metallosis; Trunnionosis; IMPLANT; METALLOSIS; FAILURE; CREVICE; STEMS;
D O I
10.1016/j.knee.2024.02.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Metallosis is a known yet rare late complication of unicompartmental and total knee arthroplasty (TKA), usually secondary to either metal -backed patellar component failure, mobile -bearing polyethylene dislocation, or catastrophic polyethylene failure and wear through. The majority of literature surrounding metallosis has been published in relation to total hip arthroplasty (THA) metal on metal bearing wear or mechanically assisted crevice corrosion. This case report describes the development of metallosis in a 77 -year -old male patient with advanced (Kellgren-Lawrence Grade 4) osteoarthritis with associated valgus deformity, who underwent index TKA with a semiconstrained revision knee system due to intraoperative medial collateral ligament laxity. The taper junction between the titanium alloy stem and cobalt chromium femoral component was the source of diffuse intra-articular metallosis. (c) 2024 Elsevier B.V. All rights reserved.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [1] Fatigue fracture of the hinge pin in a semi-constrained total knee arthroplasty: a case report
    Springorum, H. R.
    Luring, C.
    Beckmann, J.
    Schaumburger, J.
    Grifka, J.
    Tingart, M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (10) : 1366 - 1368
  • [2] SEMI-CONSTRAINED TOTAL SHOULDER ARTHROPLASTY
    COUGHLIN, MJ
    MORRIS, JM
    WEST, WF
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (04): : 574 - 581
  • [3] SEMI-CONSTRAINED TOTAL ELBOW ARTHROPLASTY
    SCHLEIN, AP
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1976, (121) : 222 - 229
  • [4] Fatigue fracture of the hinge pin in a semi-constrained total knee arthroplasty: a case report
    H. R. Springorum
    C. Luring
    J. Beckmann
    J. Schaumburger
    J. Grifka
    M. Tingart
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 1366 - 1368
  • [5] KINEMATICS OF SEMI-CONSTRAINED TOTAL ELBOW ARTHROPLASTY
    ODRISCOLL, SW
    AN, KN
    KORINEK, S
    MORREY, BF
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02): : 297 - 299
  • [6] STUDY BETWEEN SEMI-CONSTRAINED TOTAL KNEE ARTHROPLASTY WITH OR WITHOUT INTRAMEDULLARY STEM
    Albuquerque, Rodrrigo Sattamini Pires E.
    De Sousa Filho, Pedro Guilme Teixeira
    De Moraes, Rui Felipe Pache
    Franco Filho, Dalton Roberto De Melo
    Mozella, Allan
    Cobra, Hugo
    Gameiro, Vinicius Schott
    ACTA ORTOPEDICA BRASILEIRA, 2022, 30 (04):
  • [7] Coronal alignment predicts the use of semi-constrained implants in contemporary total knee arthroplasty
    Martin, J. Ryan
    Fehring, Keith A.
    Watts, Chad D.
    Levy, Daniel L.
    Springer, Bryan D.
    Kim, Raymond H.
    KNEE, 2017, 24 (04): : 863 - 868
  • [8] Long-Term Survival of Semi-Constrained Total Knee Arthroplasty for Revision Surgery
    Wilke, Benjamin K.
    Wagner, Eric R.
    Trousdale, Robert T.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (05): : 1005 - 1008
  • [9] Semi-constrained posterior stabilized total knee arthroplasty reproduces natural deep knee bending kinematics
    Takanobu Sumino
    Tetsuya Tomita
    Kazuomi Sugamoto
    Takaharu Yamazaki
    Ken Okazaki
    BMC Musculoskeletal Disorders, 21
  • [10] The evolution of total knee arthroplasty. Part II: the hinged knee replacement and the semi-constrained knee replacement
    Shetty, AA
    Tindall, A
    Ting, P
    Heatley, FW
    CURRENT ORTHOPAEDICS, 2003, 17 (05): : 403 - 410