Aerosol sources characterization and apportionment from low-cost particle sensors in an urban environment

被引:0
|
作者
Kumar, Vikas [1 ]
Malyan, Vasudev [2 ]
Sahu, Manoranjan [1 ,2 ,3 ]
Biswal, Basudev [4 ]
机构
[1] Indian Inst Technol, Interdisciplinary Program Climate Studies, Mumbai 400076, India
[2] Indian Inst Technol, Environm Sci & Engn Dept, Aerosol & Nanoparticle Technol Lab, Mumbai 400076, India
[3] Indian Inst Technol, Ctr Machine Intelligence & Data Sci, Mumbai 400076, India
[4] Indian Inst Technol, Dept Civil Engn, Mumbai 400076, India
来源
ATMOSPHERIC ENVIRONMENT-X | 2024年 / 22卷
关键词
Air pollution; Low-cost sensors; Source apportionment; Particulate matter; Non -negative matrix factorization; PARTICULATE MATTER; SIZE DISTRIBUTION; AIR-POLLUTION; EMISSIONS; DISTRIBUTIONS; MODEL; MASS; MUMBAI; NOX;
D O I
10.1016/j.aeaoa.2024.100271
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Low-cost sensors (LCS) have the potential to provide accurate and reliable measurements of air quality in realtime. This improves our ability to monitor, identify sources of pollution and develop mitigation strategies for effective air quality management. However, recent research on LCS has primarily focused on monitoring, exposure assessment, and calibration. In this study, we investigate the applicability of LCS data collected at ambient sites for characterizing and apportioning aerosol sources. Non-negative matrix factorization (NMF) was applied to the size-resolved data collected across five sites within the Indian Institute of Technology Bombay (IITB) campus in Mumbai using the LCS Alphasense OPC-N2. The sampling was done for 15 days at 5 locations in IITB, and each site only had 3 days of data. NMF resolved two factors for three sites, namely aromas (S2), hostel hub (S3) and central library (S4), while three factors were resolved for two sites, namely construction site (S1) and main gate (S5). Two common sources were determined for all the sites: (i) dust and marine source and (ii) traffic and combustion sources, which agree with the sources identified by studies in the literature. The third factor resolved at sites S1 and S5 is representative of heavy-duty diesel vehicles (HDDVs), which is present for a very short period and is captured because of the capability of high temporal resolution of the LCS. This offers a unique, cost-effective advantage of LCS for capturing episodic activities. The study suggests that in low- and middle-income countries with limited air quality monitoring capabilities, the size-time-resolved PM concentration data obtained from a network of low-cost sensors can estimate the pollution sources. This study provided evidence that despite their inherent limitations, LCS can be useful in attaining interpretable information about pollution sources and recommends extensive use of LCS for source characterization in the future.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Apportionment of urban aerosol sources in Cork (Ireland) by synergistic measurement techniques
    Dall'Osto, Manuel
    Hellebust, Stig
    Healy, Robert M.
    O'Connor, Ian P.
    Kourtchev, Ivan
    Sodeau, John R.
    Ovadnevaite, Jurgita
    Ceburnis, Darius
    O'Dowd, Colin D.
    Wenger, John C.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 493 : 197 - 208
  • [32] Low-cost Gent type sampler constructed for urban atmospheric aerosol sampling
    Franzin, Bruno Trevizan
    Hojo, Ossamu
    Ferreira, Maicon Roberto
    Forti, Maria Cristina
    Meneghetti, Carlos Daniel
    de Marchi, Mary Rosa Rodrigues
    de Oliveira, Cristina Maria Roque Ramiro
    Fertonani, Fernando Luis
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (42) : 59430 - 59438
  • [33] Low-cost Gent type sampler constructed for urban atmospheric aerosol sampling
    Bruno Trevizan Franzin
    Ossamu Hojo
    Maicon Roberto Ferreira
    Maria Cristina Forti
    Carlos Daniel Meneghetti
    Mary Rosa Rodrigues de Marchi
    Cristina Maria Roque Ramiro de Oliveira
    Fernando Luis Fertonani
    [J]. Environmental Science and Pollution Research, 2021, 28 : 59430 - 59438
  • [34] Design and characterization of a low-cost particle image velocimetry system
    Acquah, Frederick Kojo Chaway
    Takyi, Jeremiah Paul Konadu
    Beem, Heather R.
    [J]. HARDWAREX, 2024, 19
  • [35] Assessing the sources of particles at an urban background site using both regulatory instruments and low-cost sensors - a comparative study
    Bousiotis, Dimitrios
    Singh, Ajit
    Haugen, Molly
    Beddows, David C. S.
    Diez, Sebastian
    Murphy, Killian L.
    Edwards, Pete M.
    Boies, Adam
    Harrison, Roy M.
    Pope, Francis D.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (06) : 4139 - 4155
  • [36] Evaluation of a low-cost dryer for a low-cost optical particle counter
    Chacon-Mateos, Miriam
    Laquai, Bernd
    Vogt, Ulrich
    Stubenrauch, Cosima
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2022, 15 (24) : 7395 - 7410
  • [37] The source apportionment of urban aerosols from chemical properties of aerosol spectra near atmospheric sources
    Lee, CT
    Hsu, WC
    [J]. JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 1996, 19 (01) : 1 - 13
  • [38] Calibration of Low-Cost Particle Sensors by Using Machine-Learning Method
    Chen, Chen-Chia
    Kuo, Chih-Ting
    Chen, Ssu-Ying
    Lin, Chih-Hsing
    Chue, Jin-Ju
    Hsieh, Yi-Jie
    Cheng, Chun-Wen
    Wu, Chieh-Ming
    Huang, Chun-Ming
    [J]. 2018 IEEE ASIA PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS (APCCAS 2018), 2018, : 111 - 114
  • [39] Low-cost geo-data acquisition for the urban built environment
    Aydin, C. C.
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-MUNICIPAL ENGINEER, 2010, 163 (02) : 89 - 97
  • [40] A low-cost system using sparse vision for navigation in the urban environment
    Snaith, M
    Lee, D
    Probert, P
    [J]. IMAGE AND VISION COMPUTING, 1998, 16 (04) : 225 - 233