Efficacy of the Cardiac Implantable Electronic Device Multisensory Triage-HF Algorithm in Heart Failure Care: A Real-World Clinical Experience

被引:0
|
作者
Aslan, Ugur [1 ]
Beeres, Saskia L. M. A. [1 ]
Feijen, Michelle [1 ]
Mulder, Gerlinde M. [1 ]
Jukema, J. Wouter [1 ,2 ]
Egorova, Anastasia D. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, Albinusdreef 2, NL-2333 ZA Leiden, Netherlands
[2] Netherlands Heart Inst, Morseelsepk 1, NL-3511 EP Utrecht, Netherlands
关键词
cardiac implantable electronic device; multisensory algorithm; heart failure; telemonitoring; remote monitoring; RISK; HOSPITALIZATION; VALIDATION; MORTALITY; EVENTS; ALERTS;
D O I
10.3390/s24113664
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heart failure (HF) admissions are burdensome, and the mainstay of prevention is the timely detection of impending fluid retention, creating a window for medical treatment intensification. This study evaluated the accuracy and performance of a Triage-HF-guided carepath in real-world ambulatory HF patients in daily clinical practice. In this prospective, observational study, 92 adult HF patients (71 males (78%), with a median age of 69 [IQR 59-75] years) with the Triage-HF algorithm activated in their cardiac implantable electronic devices (CIEDs), were monitored. Following high-risk alerts, an HF nurse contacted patients to identify signs and symptoms of fluid retention. The sensitivity and specificity were 83% and 97%, respectively. The positive predictive value was 89%, and negative predictive value was 94%. The unexplained alert rate was 0.05 alerts/patient year, and the false negative rate was 0.11 alerts/patient year. Ambulatory diuretics were initiated or escalated in 77% of high-risk alert episodes. In 23% (n = 6), admission was ultimately required. The median alert handling time was 2 days. Fifty-eight percent (n = 18) of high-risk alerts were classified as true positives in the first week, followed by 29% in the second-third weeks (n = 9), and 13% (n = 4) in the fourth-sixth weeks. Common sensory triggers included an elevated night ventricular rate (84%), OptiVol (71%), and reduced patient activity (71%). The CIED-based Triage-HF algorithm-driven carepath enables the timely detection of impending fluid retention in a contemporary ambulatory setting, providing an opportunity for clinical action.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Efficacy of Pharmacologic and Cardiac Implantable Electronic Device Therapies in Patients With Heart Failure and Reduced Ejection Fraction: A Systematic Review and Network Meta-Analysis
    Tseng, Andrew S.
    Kunze, Katie L.
    Lee, Justin Z.
    Amin, Mustapha
    Neville, Matthew R.
    Almader-Douglas, Diana
    Killu, Ammar M.
    Madhavan, Malini
    Cha, Yong-Mei
    Asirvatham, Samuel J.
    Friedman, Paul A.
    Gersh, Bernard J.
    Mulpuru, Siva K.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (06):
  • [42] Efficacy and Safety of Semaglutide for the Management of Obese Patients With Type 2 Diabetes and Chronic Heart Failure in Real-World Clinical Practice
    Perez-Belmonte, Luis M.
    Sanz-Canovas, Jaime
    de Lucas, Maria D. Garcia
    Ricci, Michele
    Aviles-Bueno, Beatriz
    Cobos-Palacios, Lidia
    Perez-Velasco, Miguel A.
    Lopez-Sampalo, Almudena
    Bernal-Lopez, M. Rosa
    Jansen-Chaparro, Sergio
    Miramontes-Gonzalez, Jose P.
    Gomez-Huelgas, Ricardo
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [43] Real-world data of patients affected by advanced heart failure treated with implantable cardioverter defibrillator and left ventricular assist device: Results of a multicenter observational study
    Rordorf, Roberto
    Pignalosa, Leonardo
    Casula, Matteo
    Perna, Enrico
    Baroni, Matteo
    Garascia, Andrea
    Guida, Stefania
    Gazzoli, Fabrizio
    Pini, Daniela
    Cannata, Francesco
    Pellegrino, Marta
    Vittori, Claudia
    De Filippo, Paolo
    Malanchini, Giovanni
    Vergara, Pasquale
    Della Bella, Paolo
    Gulletta, Simone
    ARTIFICIAL ORGANS, 2024, 48 (05) : 525 - 535
  • [44] Real-world observational data confirm the efficacy of atrial antitachycardia pacing in terminating slow and regular atrial tachyarrhythmias in patients wearing implantable cardiac electronic devices
    Boriani, G.
    Iacopino, S.
    De Rosa, F.
    Proclemer, A.
    Infusino, T.
    Biffi, M.
    Capucci, A.
    Pisano, E.
    Zanotto, G.
    Tarricone, D.
    Marras, E.
    Zaca, V.
    EUROPEAN HEART JOURNAL, 2018, 39 : 263 - 263
  • [45] Real-World Disparities in Remote Follow-Up of Cardiac Implantable Electronic Devices and Impact of the COVID-19 Pandemic: A Single-Center Experience
    Lehmann, H. Immo
    Sharma, Krishan
    Bhatia, Roma
    Mills, Theresa
    Lang, Joshua
    Li, Guoping
    Andrews, Carl
    Cullivan, Jay
    Singh, Jagmeet
    Mela, Theofanie
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (03):
  • [46] Cardiac Implantable Electronic Device: Patients Knowledge, Attitude and Practice in Real World, insight into quality improvement project: An Observational Monocentric Study In A Tertiary Care Hospital
    Kossaify, Antoine
    Hamdan, Mira
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 : S74 - S75
  • [47] Implementation of the european society cardiac amyloidosis diagnostic algorithm for transthyretin amyloid cardiomyopathy: First real-world data on a heart failure unit in Colombia
    Rodriguez, A. L.
    Callegari, S.
    Palacio, A. C.
    Buitrago, A. F.
    Gonzalez-Robledo, G.
    EUROPEAN JOURNAL OF HEART FAILURE, 2023, 25 : 40 - 40
  • [48] REAL-WORLD SAFETYAND EFFICACY OF EARLY PRESCRIPTION OF SACUBITRIL \ VALSARTAN: APPLICATION OF THE CLINICAL PATHWAY ON HEART FAILURE OF THE "S. MARIA" HOSPITAL IN TERNI
    Lazzari, L.
    Khoury, G.
    Tilocca, G.
    Tordini, A.
    Donzelli, S.
    Bovelli, D.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0E) : E48 - E48
  • [49] Use Of Implantable Pulmonary Artery Pressure Monitoring To Guide Care Of Patients With Ambulatory Heart Failure; The First Three Years In A Real World, Single Center Experience
    Turk, Ahmad
    Khariton, Yevgeniy
    Kao, Andrew
    Khumri, Taiyeb
    Sperry, Brett
    Magalski, Anthony
    Austin, Bethany
    Lawhorn, Stephanie
    Vodnala, Deepthi
    Nassif, Michael
    Fendler, Timothy J.
    JOURNAL OF CARDIAC FAILURE, 2022, 28 (05) : S42 - S42
  • [50] Remote Monitoring of Cardiac Implantable Electronic Devices in Patients Undergoing Hybrid Comprehensive Telerehabilitation in Comparison to the Usual Care. Subanalysis from Telerehabilitation in Heart Failure Patients (TELEREH-HF) Randomised Clinical Trial
    Pluta, Slawomir
    Piotrowicz, Ewa
    Piotrowicz, Ryszard
    Lewicka, Ewa
    Zareba, Wojciech
    Koziel, Monika
    Kowalik, Ilona
    Pencina, Michael J.
    Oreziak, Artur
    Cacko, Andrzej
    Szalewska, Dominika
    Glowczynska, Renata
    Banach, Maciej
    Opolski, Grzegorz
    Orzechowski, Piotr
    Irzmanski, Robert
    Kalarus, Zbigniew
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (11) : 1 - 13