Efficacy of the Cardiac Implantable Electronic Device Multisensory Triage-HF Algorithm in Heart Failure Care: A Real-World Clinical Experience

被引:0
|
作者
Aslan, Ugur [1 ]
Beeres, Saskia L. M. A. [1 ]
Feijen, Michelle [1 ]
Mulder, Gerlinde M. [1 ]
Jukema, J. Wouter [1 ,2 ]
Egorova, Anastasia D. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, Albinusdreef 2, NL-2333 ZA Leiden, Netherlands
[2] Netherlands Heart Inst, Morseelsepk 1, NL-3511 EP Utrecht, Netherlands
关键词
cardiac implantable electronic device; multisensory algorithm; heart failure; telemonitoring; remote monitoring; RISK; HOSPITALIZATION; VALIDATION; MORTALITY; EVENTS; ALERTS;
D O I
10.3390/s24113664
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heart failure (HF) admissions are burdensome, and the mainstay of prevention is the timely detection of impending fluid retention, creating a window for medical treatment intensification. This study evaluated the accuracy and performance of a Triage-HF-guided carepath in real-world ambulatory HF patients in daily clinical practice. In this prospective, observational study, 92 adult HF patients (71 males (78%), with a median age of 69 [IQR 59-75] years) with the Triage-HF algorithm activated in their cardiac implantable electronic devices (CIEDs), were monitored. Following high-risk alerts, an HF nurse contacted patients to identify signs and symptoms of fluid retention. The sensitivity and specificity were 83% and 97%, respectively. The positive predictive value was 89%, and negative predictive value was 94%. The unexplained alert rate was 0.05 alerts/patient year, and the false negative rate was 0.11 alerts/patient year. Ambulatory diuretics were initiated or escalated in 77% of high-risk alert episodes. In 23% (n = 6), admission was ultimately required. The median alert handling time was 2 days. Fifty-eight percent (n = 18) of high-risk alerts were classified as true positives in the first week, followed by 29% in the second-third weeks (n = 9), and 13% (n = 4) in the fourth-sixth weeks. Common sensory triggers included an elevated night ventricular rate (84%), OptiVol (71%), and reduced patient activity (71%). The CIED-based Triage-HF algorithm-driven carepath enables the timely detection of impending fluid retention in a contemporary ambulatory setting, providing an opportunity for clinical action.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Performance of the multisensory cardiac implantable electronic device algorithm HeartLogic in a real-world ambulant chronic heart failure population
    Feijen, M.
    Egorova, A. D.
    Treskes, R. W.
    Schalij, M. J.
    Beeres, S. L. M. A.
    EUROPEAN HEART JOURNAL, 2021, 42 : 713 - 713
  • [2] Analysis of the implementation of a multisensory cardiac implantable electronic device algorithm based heart failure carepath in real-life practice
    Feijen, M.
    Beeres, S. L. M. A.
    Treskes, R. W.
    Schalij, M. J.
    Egorova, A. D.
    EUROPEAN JOURNAL OF HEART FAILURE, 2021, 23 : 16 - 16
  • [3] Evaluation of real-world application of cardiac implantable electronic device-based multi-sensor algorithm for heart failure management
    Llewellyn, Jennifer
    Goode, Rachel
    Kahn, Matthew
    Valsecchi, Sergio
    Rao, Archana
    EUROPEAN HEART JOURNAL - DIGITAL HEALTH, 2025,
  • [4] CARDIAC IMPLANTABLE ELECTRONIC DEVICE COMPLICATIONS IN A REAL-WORLD SETTING
    Quinn, S.
    Elhadi, M.
    Weedle, R.
    Nolan, P.
    Keane, S.
    Murphy, T.
    Hynes, B.
    Smyth, Y.
    MacNeill, B.
    Crowley, J.
    Nash, P.
    HEART, 2019, 105 : A13 - A14
  • [5] Remote monitoring of cardiac implantable electronic devices for predicting acute clinical decompensation events in heart failure patients: an integrated diagnostic algorithm evaluation in a real-world
    Tinoco, M. Mariana
    Castro, M.
    Mota, M.
    Pinheiro, L.
    Mata, E.
    Almeida, F.
    Ribeiro, S.
    Calvo, L.
    Cardoso, F.
    Faria, B.
    Rodrigues, B.
    Mendes, C.
    Sanfins, V.
    Lourenco, A.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 34 - 35
  • [6] Challenges in cardiac implantable electronic device surveillance: Insights from real-world data
    Prousi, George S.
    Mason, Pamela K.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (12) : 2312 - 2313
  • [7] The Impact of Prophylactic Heparin on Pocket Hematoma Formation After Cardiac Implantable Electronic Device Implantation a Real-World Experience
    Patel, Harsh P.
    Kumar, Ashish
    Agarwal, Siddharth
    Mazimba, Sula
    Deshmukh, Abhishek
    Mehta, Nishaki M.
    CIRCULATION, 2023, 148
  • [8] Impact of sacubitril/valsartan on implantable defibrillator eligibility in heart failure: a real-world experience
    Monzo, Luca
    Ferrari, Ilaria
    Gaudio, Carlo
    Cicogna, Francesco
    Tota, Claudia
    Petronilli, Valentina
    Mennuni, Silvia
    Ruvo, Ermenegildo De
    Calo, Leonardo
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (SUPPL G)
  • [9] Impact of sacubitril/valsartan on implantable defibrillator eligibility in heart failure: a real-world experience
    Monzo, L.
    Gaudio, C.
    Cicogna, F.
    Tota, C.
    Petronilli, V
    Mennuni, S.
    De Ruvo, E.
    Calo, L.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2021, 25 (18) : 5690 - 5700
  • [10] Impact of sacubitril/valsartan on implantable defibrillator eligibility in heart failure: a real-world experience
    Monzo, L.
    Cicogna, F.
    Tota, C.
    Petronilli, V.
    Mennuni, S.
    De Ruvo, E.
    Calo, L.
    EUROPEAN JOURNAL OF HEART FAILURE, 2021, 23 : 42 - 43