OSG-PLL-based method of a solar PV grid-interfaced transformer-less cascaded H-bridge multilevel inverter for power quality enhancement

被引:1
|
作者
Malle, Lingamaiah [1 ]
Mittal, Arvind [1 ]
Kumar, Shailendra [2 ]
机构
[1] MANIT, Energy Ctr, Bhopal, India
[2] IIT Bhilai, Dept Elect Engn, Bhilai, India
关键词
PV array; Proportional-integral; Multilevel inverter; Cascaded H-bridge; Power quality; LCL-FILTER; PHOTOVOLTAIC SYSTEMS; CONNECTED INVERTER; DESIGN; TOPOLOGIES; EFFICIENCY; SCHEME;
D O I
10.1007/s00202-024-02460-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ever-growing demand for renewable energy sources has prompted significant interest in the integration of solar photovoltaic (SPV) system into the power grid. Transformer-based inverters in PV system not only elevate the weight, size, and cost of the inverter but also diminish its efficiency. To address this issue, this research presents a single-phase transformer-less five-level cascaded H-bridge multilevel inverter (CHB-MLI) using a single SPV source. The primary objective of this study is to enhance power quality and mitigate harmonics while integrating renewable energy sources into the grid. To control the inverter output voltage, a phase disposition-pulse width modulation (PD-PWM) technique is applied. An orthogonal signal generator-based phase-locked loop (OSG-PLL) is implemented to synchronize the inverter output with the grid voltage and frequency. To regulate the DC link voltage, grid voltage and current a cascaded proportional-integral (PI) and proportional resonant (PR) control strategy is implemented. The self-voltage balancing capability and simplified control scheme of this CHB-MLI make it highly suitable for PV applications. A comparative analysis is conducted to assess the strengths and weaknesses of the suggested multilevel inverter topology. The proposed control strategy improves power quality, reducing multilevel inverter voltage distortion to 4.20% and grid current distortion to 1.91%. The performance of both standalone and grid-connected system is evaluated using MATLAB/Simulink and validated in real time using OPAL-RT (OP5600) test setup.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Grid Connection of Wave Power Farm Using an N-Level Cascaded H-Bridge Multilevel Inverter
    Ekstrom, Rickard
    Leijon, Mats
    JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2013, 2013
  • [32] Power Balance Control Scheme of Cascaded H-Bridge Multilevel Inverter for Grid-Connection Photovoltaic Systems
    Wang, Fusheng
    Yang, Le
    Mao, Wang
    Yu Shineng
    Zhang, Xing
    2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,
  • [33] Trinary Hybrid Cascaded H-Bridge Multilevel Inverter-Based Grid-Connected Solar Power Transfer System Supporting Critical Load
    Mukundan, Nirmal Mukundan Chakkamath
    Pychadathil, Jayaprakash
    Subramaniam, Umashankar
    Almakhles, Dhafer J.
    IEEE SYSTEMS JOURNAL, 2021, 15 (03): : 4116 - 4125
  • [34] 5-level Cascaded H-Bridge Multilevel Microgrid Inverter Applicable to Multiple DG Resources with Power Quality Enhancement Capability
    Mortezaei, Ali
    Simoes, M. Godoy
    Marafao, Fernando P.
    Al Durra, Ahmed
    2015 IEEE 13TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 1ST SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2015,
  • [35] Realization of Cascaded H-Bridge Multilevel Inverter Based Grid Integrated Solar Energy System With Band Stop Generalized Integral Control
    Mukundan, Nirmal C. M.
    Jayaprakash, P.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2021, 57 (01) : 764 - 773
  • [36] A Parallel Control Strategy for Power Mismatch Elimination of Photovoltaic Grid-Connected Cascaded H-Bridge Multilevel Inverter
    Pan, Xicai
    Pan, Shangzhi
    Gong, Jinwu
    Zha, Xiaoming
    2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, : 4957 - 4962
  • [37] Hardware Implementation of Power Quality Improvement in Photo-voltaic Fed Cascaded H-bridge Multilevel Inverter
    Letha, Shimi Sudha
    Thakur, Tilak
    Kumar, Jagdish
    2018 IEEE 27TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2018, : 401 - 406
  • [38] Control of a Transformer-less Cascaded H-bridge Based STATCOM Using Low-Frequency Selective Harmonic Elimination Technique
    Neyshabouri, Y.
    Iman-Eini, H.
    Farhangi, Sh.
    2013 12TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC 2013), 2013, : 495 - 500
  • [39] Power Sharing Control for a Microgrid with PV Power Plants, Batteries and Quasi-Z-source Cascaded H-bridge Multilevel Inverter
    Horrillo-Quintero P.
    García-Triviño P.
    Sarrias-Mena R.
    García-Vázquez C.A.
    Fernández-Ramírez L.M.
    Renewable Energy and Power Quality Journal, 2023, 21 (06): : 712 - 717
  • [40] Power enhancement of single-phase transformer-less grid-connected cascaded half-bridge diode clamped inverter under partial shaded photovoltaic
    Rao, Pandry Narendra
    Saini, Lalit Mohan