Numerical Investigation of Fiber Reinforced Polymer Retrofitted Short Reinforced Concrete Circular Columns under Concentric Compressive Load

被引:0
|
作者
Parghi, A. [1 ]
Patel, M. [1 ]
Lunagaria, M. H. [1 ]
机构
[1] Sardar Vallabhbhai Natl Inst Technol, Dept Civil Engn, Surat, Gujarat, India
来源
INTERNATIONAL JOURNAL OF ENGINEERING | 2024年 / 37卷 / 10期
关键词
Fiber Reinforced Polymer; Circular Reinforced Concrete Columns; Retrofitting; Pre-Load; Finite Element Method; MECHANICAL-PROPERTIES; FRP; STRENGTH; BEHAVIOR; DAMAGE; WATER; MODEL; BARS;
D O I
10.5829/ije.2024.37.10a.02
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The presents study numerically investigates the fiber-reinforced polymer (FRP) retrofitted short-damaged reinforced concrete (RC) columns subjected to axial compression load. The main parameter considered to evaluate the effectiveness of FRP retrofitting on circular columns with different aspect ratios, concrete grade, and FRP material. To simulate the behaviour of a short RC column under a uniaxial compression load, a finite element model of the column was developed. The model was then modified to simulate the various level of damage to the column and the behaviour of the column under uniaxial load. The effectiveness of FRP retrofit was studied comparing the behaviour of the retrofitted column to the damaged column. For M20 concrete column retrofitted with carbon fiber reinforced polymer (CFRP) showed a higher strength (2 to 3 times) than glass fiber reinforced polymer (GFRP) retrofitted columns. For M30 concrete, the range is quite similar (1.5 - 2.3 times more). The effectiveness of both FRPs retrofitted columns increases with increasing aspect ratio from 2 and 3, but slightly decreases for an aspect ratio of 4 compared to the damaged specimen. The maximum effectiveness achieved for CFRP retrofitted columns is of 19.45% and for GFRP retrofitted column is of 10.71%, and the other grade of concrete (M30) followed a similar trend. The load-bearing capacity of columns has no significant effect by the increase in aspect ratio from 2 to 4.
引用
收藏
页码:1882 / 1890
页数:9
相关论文
共 50 条
  • [21] Flexural behavior of concrete columns retrofitted with carbon fiber-reinforced polymer jackets
    Sause, R
    Harries, KA
    Walkup, SL
    Pessiki, S
    Ricles, JM
    ACI STRUCTURAL JOURNAL, 2004, 101 (05) : 708 - 716
  • [22] Composite response of circular tubed reinforced concrete short columns under cyclic lateral load
    Gan, Dan
    Zhou, Xuhong
    Liu, Jiepeng
    Li, Jiang
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 : 222 - 229
  • [23] Fiber Reinforced Polymer (FRP) Confined Circular Columns: Compressive Strength Assessment
    Papakonstantinou C.G.
    Journal of Engineering Science and Technology Review, 2020, 13 (06) : 1 - 13
  • [24] Strength of concrete columns reinforced with Glass fiber reinforced polymer
    Duy, Nguyen Phan
    Anh, Vu Ngoc
    Hiep, Dang Vu
    Anh, Nguyen Minh Tuan
    Magazine of Civil Engineering, 2021, 101 (01):
  • [25] Experimental investigation on the compressive behavior of short-term preloaded carbon fiber reinforced polymer-confined concrete columns
    Ferrotto, Marco Filippo
    Fischer, Oliver
    Niedermeier, Roland
    STRUCTURAL CONCRETE, 2018, 19 (04) : 988 - 1001
  • [26] Investigation into the structural behavior of reinforced concrete beams externally retrofitted with carbon fiber reinforced polymer composites
    Mouring, S
    Barton, O
    Simmons, DK
    2001 SECOND INTERNATIONAL CONFERENCE ON ENGINEERING MATERIALS, VOL II, 2001, : 409 - 418
  • [27] Strength of concrete columns reinforced with Glass fiber reinforced polymer
    Duy, N. P.
    Anh, V. N.
    Hiep, D., V
    Anh, N. M. T.
    MAGAZINE OF CIVIL ENGINEERING, 2021, 101 (01):
  • [28] Experimental Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns under Lateral Cyclic Load
    Elshamandy, Mohammed G.
    Farghaly, Ahmed Sabry
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2018, 115 (02) : 337 - 349
  • [29] Behavior of Full-Scale Glass Fiber-Reinforced Polymer Reinforced Concrete Columns under Axial Load
    De Luca, Antonio
    Matta, Fabio
    Nanni, Antonio
    ACI STRUCTURAL JOURNAL, 2010, 107 (05) : 589 - 596
  • [30] Investigation of interface response of reinforced concrete columns retrofitted with composites
    Achillopoulou, Dimitra V.
    Kiziridou, Alexandra N.
    Papachatzakis, Georgios A.
    Karabinis, Athanasios I.
    STEEL AND COMPOSITE STRUCTURES, 2016, 22 (06): : 1337 - 1358