A covalent-organic framework-based platform for simultaneous smartphone detection and degradation of aflatoxin B1

被引:0
|
作者
Zhou, Lingling [1 ]
Duan, Xueting [1 ]
Dai, Jiayin [3 ]
Ma, Yongchao [2 ]
Yang, Qingli [1 ]
Hou, Xiudan [1 ]
机构
[1] Qingdao Agr Univ, Coll Food Sci & Engn, Qingdao, Peoples R China
[2] Qingdao Agr Univ, Coll Chem & Pharmaceut Sci, Qingdao, Peoples R China
[3] UCL, Div Biosci, London, England
关键词
Aflatoxin B1; Covalent organic framework; Nanozyme; Colorimetric biosensor; Degradation;
D O I
10.1016/j.talanta.2024.126505
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study developed a smartphone-based biosensor that could simultaneously detect and degrade aflatoxin B1 (AFB1). A donor-acceptor covalent organic framework (COF) was bound onto the surface of stainless-steel mesh (SSM) via the in-situ synthesis, which was used to immobilize the aptamer (Apt) to specifically capture AFB1 and was also as a photocatalyst to degrade AFB1. Au@Ir nanospheres were synthesized, which exhibited better peroxidase catalytic activity (Km=5.36 x 10-6 M, Vmax=3.48 x 10-7 Ms- 1, Kcat=1.00 x 107 s- 1) than Ir@Au nanospheres, so Au@Ir nanospheres were linked with Apt2 to be utilized as the signal probe. The density functional theory calculation also described that Au@Ir nanospheres possessed the lower energy barriers to decompose H2O2 than Ir@Au nanospheres. Coupled with the "Color Picker" application in the smartphone, the established "sandwich-structure" colorimetric method exhibited a linear range of 0.5-200 mu g L-1 and a detection limit of 0.045 mu g L-1. The photocatalytic capacity of SSM/COF towards AFB1 was investigated and the degradation rate researched 81.14 % within 120 min under the xenon lamp irradiation, and the degradation products were validated by ESI-MS. It was applied for the detection of AFB1 in peanuts, corn, and wheat samples. Recoveries were ranging from 77.90 % to 112.5 %, and the matrix effect was 75.10-111.6 %. Therefore, the smartphone-based biosensor provided a simple, fast, and sensitive platform for the detection of AFB1, and meanwhile could realize the efficient degradation of AFB1.
引用
下载
收藏
页数:10
相关论文
共 50 条
  • [41] Heteroporous 3D covalent organic framework-based magnetic nanospheres for sensitive detection of bisphenol A
    Lu, Feifei
    Lin, Jian
    Lin, Chenchen
    Qi, Guomin
    Lin, Xucong
    Xie, Zenghong
    TALANTA, 2021, 231
  • [42] Aflatoxin B1 Detection Using a Highly-Sensitive Molecularly-Imprinted Electrochemical Sensor Based on an Electropolymerized Metal Organic Framework
    Jiang, Mengjuan
    Braiek, Mohamed
    Florea, Anca
    Chrouda, Amani
    Farre, Carole
    Bonhomme, Anne
    Bessueille, Francois
    Vocanson, Francis
    Zhang, Aidong
    Jaffrezic-Renault, Nicole
    TOXINS, 2015, 7 (09): : 3540 - 3553
  • [43] Electrochemistry–glucosemeter–smartphone integrated multi-mode biosensor for accurate detection of aflatoxin B1
    Suo, Zhiguang
    Lu, Tao
    Liu, Jiahui
    Li, Jiayi
    Wang, Li
    Liu, Yong
    Wei, Min
    Analytica Chimica Acta, 2025, 1333
  • [44] An Antibody Ordered Assembly Functional BPE-ECL Platform for Aflatoxin B1 Detection
    Fanglin Qiao
    Yin Chen
    Yunjie Fei
    Yanjun Jiang
    Xiaohui Xiong
    Yuanjian Liu
    Food Analytical Methods, 2024, 17 : 260 - 268
  • [45] An Antibody Ordered Assembly Functional BPE-ECL Platform for Aflatoxin B1 Detection
    Qiao, Fanglin
    Chen, Yin
    Fei, Yunjie
    Jiang, Yanjun
    Xiong, Xiaohui
    Liu, Yuanjian
    FOOD ANALYTICAL METHODS, 2024, 17 (02) : 260 - 268
  • [46] Smartphone-based chemiluminescence detection of aflatoxin B1 via labelled and label-free dual sensing systems
    Ma, Junning
    Guan, Yue
    Xing, Fuguo
    Wang, Yan
    Li, Xu
    Yu, Qiang
    Yu, Xiaohua
    FOOD CHEMISTRY, 2023, 413
  • [47] Simultaneous Determination of Aflatoxin B1 and Ochratoxin A in Cereals by a Novel Electrochemical Aptasensor Using Metal-Organic Framework as Signal Carrier
    Xu, Yiwei
    Jia, Xupeng
    Yang, Sennan
    Cao, Mengrui
    He, Baoshan
    Ren, Wenjie
    Suo, Zhiguang
    FOODS, 2024, 13 (14)
  • [48] Fabrication of a metal-organic framework composite for removal of Aflatoxin B1 from water
    Samuel, Melvin S.
    Kirankumar, V. S.
    Selvarajan, E.
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (01):
  • [49] Covalent organic framework-based ratiometric electrochemical sensing platform for ultrasensitive determination of amyloid-(3 42 oligomer
    Liu, Jingjie
    Zhao, Haiyan
    Hu, Shuyang
    Li, Na
    Cui, Min
    Han, Bingkai
    Li, Meng
    Zhang, Cong
    TALANTA, 2024, 280
  • [50] A Metal Organic Framework-Based Light Scattering ELISA for the Detection of Staphylococcal Enterotoxin B
    Mao, Kai
    Tian, Lili
    Luo, Yujie
    Li, Qian
    Chen, Xi
    Zhan, Lei
    Li, Yuanfang
    Huang, Chengzhi
    Zhen, Shujun
    CHEMOSENSORS, 2023, 11 (08)