Assessment of radiation exposure risks in patients undergoing elastic stable intramedullary nailing: Insights from intraoperative fluoroscopy

被引:1
|
作者
Safari, A. [1 ,2 ]
Falahati, F. [1 ,2 ]
Bahaedini, N. [3 ]
Fardid, R. [1 ,2 ]
Mesbahi, S. E. [3 ,4 ]
机构
[1] Shiraz Univ Med Sci, Ionizing & Nonionizing Radiat Protect Res Ctr INIR, Sch Paramed Sci, Shiraz, Iran
[2] Shiraz Univ Med Sci, Paramed Sch, Dept Radiol, Shiraz, Iran
[3] Emtyiaz Trauma Ctr, Med Imaging & Radiat Protect, Shiraz, Iran
[4] Amirkabir Univ Technol, Dept Biomed Engn, Tehran, Iran
关键词
Intraoperative radiation; Effective dose; Cancer risk; Elastic stable intramedullary nailing; X-RAY TREATMENT; CANCER-RISK; CONVERSION FACTORS; POOLED ANALYSIS; FRACTURES; CHILDREN; INFANCY; FEMUR; ERCP; TIME;
D O I
10.1016/j.radi.2024.06.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Elastic stable intramedullary nailing (ESIN) is a well-defined and appropriate treatment of choice for long bone fractures. Despite its benefits, the risk of cancer from imaging devices is of particular concern for younger adults. So, this survey was conducted to estimate the doses administered to patients undergoing ESIN of long bone fractures utilizing a 2-dimensional (2D) C-arm fluoroscopy machine during surgery, as well as the carcinogenic risk associated with the use of the machine. Methods: This study was conducted on 147 patients who required ESIN for long-bone fractures. Patients' demographic data, surgical data and imaging information were collected. For each patient, the organ doses and the effective doses were computed with the Monte Carlo PCXMC 2.0 simulation software. The cancer risk models proposed in the Biological Effects of Ionizing Radiation VII (BEIR VII) Phase 2 report were used to evaluate the risk of exposure-induced cancer death (REID) values. Results: For all patients, the highest organ dose was delivered to the gonads. The mean effective dose was 0.026 +/- 0.015 mSv and 1.3E-0 4 +/- 1E-04 mSv for ESIN of femur and tibia fractures, respectively. Males had a mean REID of 1 per million, while females had a mean REID of 0.19 per million. The younger males had considerably higher REID values. The effective dose was significantly correlated with age, gender, and irradiation time. Conclusion: Low levels of effective doses and cancer risks associated with the utilization of the fluoroscopy machine in current practice were found in ESIN treatment of long-bone fractures. Implications for practice: This outcome will help to raise surgeons' awareness of radiation risks and encourage them to initiate measures to keep radiation dose and exposure time as low as reasonably achievable. (c) 2024 The College of Radiographers. Published by Elsevier Ltd. All rights are reserved, including those
引用
收藏
页码:1225 / 1231
页数:7
相关论文
共 50 条
  • [21] Peer assessment of pediatric surgeons for potential risks of radiation exposure from computed tomography scans
    Rice, Henry E.
    Frush, Donald P.
    Harker, Matthew J.
    Farmer, Diana
    WaLdhausen, John H.
    JOURNAL OF PEDIATRIC SURGERY, 2007, 42 (07) : 1157 - 1164
  • [22] Risks of chemotherapy exposure from transporting chemotherapy patients to radiation oncology departments.
    Moore, K
    Haas, M
    Goyer, P
    ONCOLOGY NURSING FORUM, 2005, 32 (01) : 194 - 194
  • [23] Assessment of radiation dose rate emitted from patients undergoing iodine therapy
    Biraima, Walialdeen H.
    Ali, A. S. M.
    Saeed, M. Khalil
    Ibrahim, Ahmed. M.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 203
  • [24] Functional and radiological outcome in patients with acute Monteggia fracture treated surgically: a comparison between closed reduction and external fixation versus closed reduction and elastic stable intramedullary nailing
    Yuan, Zhe
    Xu, HongWen
    Li, YiQiang
    Li, JingChun
    Liu, YanHan
    Canavese, Federico
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2020, 29 (05): : 438 - 444
  • [25] AN ASSESSMENT OF RADIATION EXPOSURE DOSES IN PATIENTS UNDERGOING PRIMARY PERCUTANEOUS CORONARY INTERVENTION BASED ON ANGIOGRAPHIC RECORDS
    Maghbool, M.
    Hosseini, M. A.
    RADIATION PROTECTION DOSIMETRY, 2019, 183 (04) : 475 - 482
  • [26] assessment of prospective cancer risks from occupational exposure to ionising radiation (IAEA-TECDOC-1985)
    Harbron, Richard W.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (03)
  • [27] IONIZING RADIATION EXPOSURE FROM MEDICAL IMAGING IN DIALYZED PATIENTS UNDERGOING RENAL PRETRANSPLANT EVALUATION
    De Mauri, Andreana
    Doriana, Chiarinotti
    Brambilla, Marco
    Matheoud, Roberta
    David, Paola
    Capurro, Federica
    Brustia, Maddalena
    Ruva, Carlo Edoardo
    De Leo, Martino
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2014, 29 : 511 - 511
  • [28] Transitions of Care Among Patients Undergoing Percutaneous Coronary Intervention for Stable Angina: Insights From the Veterans Affairs Clinical Assessment Reporting and Tracking Program
    Waldo, Stephen W.
    Glorioso, Thomas J.
    Baron, Anna E.
    Doll, Jacob A.
    Plomondon, Mary E.
    Ho, P. Michael
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2022, 11 (04):
  • [29] Cancer and mortality risks of patients with scoliosis from radiation exposure: a systematic review and meta-analysis
    Fu-Jun Luan
    Yi Wan
    Kin-Cheung Mak
    Chi-Jiao Ma
    Hai-Qiang Wang
    European Spine Journal, 2020, 29 : 3123 - 3134
  • [30] Cancer and mortality risks of patients with scoliosis from radiation exposure: a systematic review and meta-analysis
    Luan, Fu-Jun
    Wan, Yi
    Mak, Kin-Cheung
    Ma, Chi-Jiao
    Wang, Hai-Qiang
    EUROPEAN SPINE JOURNAL, 2020, 29 (12) : 3123 - 3134