Automated method for measuring body size parameters of live pigs based on non-rigid registration of point clouds

被引:0
|
作者
Gao, Zicheng [1 ]
Lei, Jie [1 ]
Wu, Jianhuan [1 ]
Zhang, Jialong [2 ]
Ruchay, Alexey [3 ]
Pezzuolo, Andrea [4 ]
Guo, Hao [1 ]
机构
[1] China Agr Univ, Coll Land Sci & Technol, Beijing 100083, Peoples R China
[2] China Agr Univ, Coll Informat & Elect Engn, Beijing 100083, Peoples R China
[3] Russian Acad Sci, Fed Res Ctr Biol Syst & Agrotechnol, 9 Yanvarya 29, Orenburg 460000, Russia
[4] Univ Padua, Dept Land Environm Agr & Forestry, Viale Univ 16, I-35020 Legnaro, PD, Italy
基金
中国国家自然科学基金;
关键词
body size measurement; automated method; non-rigid registration; 3D point cloud; pig farming; VISUAL IMAGE-ANALYSIS; GROWTH; SYSTEM;
D O I
10.1109/MetroAgriFor58484.2023.10424170
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
With the increasing demand of human and the development of automation technology, there is an urgent need for automated livestock body measurement methods. An object of this paper is to investigate an automated method for measuring body size parameters of live pigs based on non-rigid registration of point clouds. We choose Xtion pro camera as point cloud acquisition equipment to obtain RGB-D data from the upper left and upper right. Pig body point clouds are extracted from the acquired data after preprocessing. We perform coarse registration to the measured point clouds and the template point cloud so that the two point clouds are aligned. Moreover, non-rigid registration methods are used in order to make the shape of the measured data fit with the template data. Finally, the different body size parameters are estimated according to the landmarks that marked on the template point cloud in advance. The results have shown that this method is reliable for measuring pig body size parameters compared to manually measured values, especially in measuring the hip height, shoulder width, and hip width, in which the average relative errors are 2.92%, 5.78%, and 4.83%.
引用
收藏
页码:472 / 477
页数:6
相关论文
共 50 条
  • [41] Inverse consistent non-rigid image registration based on robust point set matching
    Yang, Xuan
    Pei, Jihong
    Shi, Jingli
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [42] Non-Rigid Point Set Registration Based on Neighborhood Structure and Driving Force Criterion
    He K.
    Liu Z.
    Li D.
    Zhao Y.
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2022, 50 (04): : 73 - 80
  • [43] Non-Rigid Point Set Registration Based on Variational Bayes Hierarchical Probability Model
    He Q.-Q.
    Lin G.
    Zhou J.
    Yang Y.
    Jisuanji Xuebao/Chinese Journal of Computers, 2021, 44 (09): : 1866 - 1887
  • [44] Robust CPD Algorithm for Non-Rigid Point Set Registration Based on Structure Information
    Peng, Lei
    Li, Guangyao
    Xiao, Mang
    Xie, Li
    PLOS ONE, 2016, 11 (02):
  • [45] Inverse consistent non-rigid image registration based on robust point set matching
    Xuan Yang
    Jihong Pei
    Jingli Shi
    BioMedical Engineering OnLine, 13
  • [46] Non-rigid Point Set Registration Based on DIS&ANG Descriptor and RANSAC
    Dou, Jun
    Lin, Xue
    Niu, Dongmei
    Zhao, Xiuyang
    2017 2ND INTERNATIONAL CONFERENCE ON IMAGE, VISION AND COMPUTING (ICIVC 2017), 2017, : 693 - 697
  • [47] REGULARIZED SURFACE AND POINT LANDMARKS BASED EFFICIENT NON-RIGID MEDICAL IMAGE REGISTRATION
    Shah, Said Khalid
    COMPUTING AND INFORMATICS, 2018, 37 (01) : 244 - 268
  • [48] A non-rigid cardiac image registration method based on an optical flow model
    Lu, Xiaoqi
    Zhao, Yongjie
    Zhang, Baohua
    Wu, Jianshuai
    Li, Na
    Jia, Weitao
    OPTIK, 2013, 124 (20): : 4266 - 4273
  • [49] Effective Non-rigid Image Registration Method Based on Active Demons Algorithm
    Tang, Zhenchao
    Xue, Peng
    Yang, Pei
    Jia, Dayu
    Dong, Enqing
    2016 IEEE 29TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2016, : 124 - 129
  • [50] Medical image non-rigid registration based on improved finite element method
    Xu, Shengzhou
    Hu, Huaifei
    Sensors and Transducers, 2013, 161 (12): : 568 - 573