Outcomes and Predictors of Stroke After Transcatheter Aortic Valve Replacement in the Cerebral Protection Device Era

被引:1
|
作者
Shekhar, Shashank [1 ]
Isogai, Toshiaki [1 ]
Agrawal, Ankit [1 ]
Kaw, Roop [1 ]
Mahalwar, Gauranga [1 ]
Krishnaswamy, Amar [1 ]
Puri, Rishi [1 ]
Reed, Grant [1 ]
Mentias, Amgad [1 ]
Kapadia, Samir [1 ]
机构
[1] Cleveland Clin, Heart Vasc & Thorac Inst, Dept Cardiovasc Med, 9500 Euclid Ave,J2-3, Cleveland, OH 44195 USA
来源
关键词
cerebral embolic protection; sentinel device; stroke; TAVR; EMBOLIC PROTECTION; CEREBROVASCULAR EVENTS; TAVR; ASSOCIATION; STENOSIS;
D O I
10.1161/JAHA.124.034298
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Studies have shown inconclusive results on the effectiveness of cerebral protection devices (CPDs) with transcatheter aortic valve replacement. We aimed to analyze the national statistics on stroke and other outcomes with CPD use.Methods and Results The Nationwide Readmissions Database (2017-2020) was queried to obtain data on patients undergoing transcatheter aortic valve replacement. Outcomes were compared between patients with a CPD and patients without a CPD. Of 271 804 patients undergoing transcatheter aortic valve replacement, CPD was used in 7.3% of patients. In a multivariable logistic regression analysis, CPD use was not associated with lower overall stroke rates (1.6% versus 1.9% without CPD; odds ratio, 0.95 [95% CI, 0.84-1.07]; P=0.364), but it was significantly associated with lower major stroke rates (1.2% versus 1.5% without CPD; odds ratio, 0.85 [95% CI, 0.74-0.98]; P=0.02). Patients with a CPD also had a shorter length of stay, higher routine discharges to home/self-care (74.9% versus 70.6%), and lower mortality rates (0.7% versus 1.3%). The 30-day (9.6% versus 11.7%) and 180-day (24.6% versus 28.2%) readmission rates were significantly lower in the CPD cohort. Among patients who developed stroke, patients with a CPD had more frequent routine discharges. Prior valve surgery was associated with the highest risk of overall and major stroke.Conclusions CPD use during transcatheter aortic valve replacement was not independently associated with a lower risk of overall stroke but was associated with a lower risk of major stroke in a multivariable model. Data from future randomized trials that may offset any potential confounders in our study are required to help identify patients who would benefit from the use of these devices.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Cerebral embolic protection device utilization and outcomes in transcatheter aortic valve replacement: A nationally representative propensity matched analysis
    Altibi, Ahmed M.
    Alhuneafat, Laith
    Jabri, Ahmad
    Al-Abdouh, Ahmad
    Ghanem, Fares
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 67 : 112 - 114
  • [32] Outcomes of isolated surgical aortic valve replacement in the era of transcatheter aortic valve implantation
    Ram, Eilon
    Amunts, Sergei
    Zuroff, Elchanan
    Peled, Yael
    Kogan, Alexander
    Raanani, Ehud
    Sternik, Leonid
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (07) : 1452 - 1457
  • [33] Clinical Outcome of Transcatheter Aortic Valve Replacement With TriGUARD 3 Cerebral Embolic Protection Device
    Daal, Sayonara
    Jimenez-Rodriguez, Gian
    Voskuil, Michiel
    Kraaijeveld, Adriaan
    Dessing, Thomas
    Ramjankhan, Faiz
    Mokhles, Mostafa
    Stella, Pieter
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B133 - B134
  • [34] TriGuard™ HDH Embolic Deflection Device for Cerebral Protection During Transcatheter Aortic Valve Replacement
    Samim, Mariam
    van der Worp, Bart
    Agostoni, Pierfrancesco
    Hendrikse, Jeroen
    Budde, Ricardo P. J.
    Nijhoff, Freek
    Ramjankhan, Faiz
    Doevendans, Pieter A.
    Stella, Pieter R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 (03) : 470 - 477
  • [35] Cerebral Embolic Protection Devices in Transcatheter Aortic Valve Replacement-Effective in Stroke Prevention?
    Khera, Rohan
    Girotra, Saket
    JAMA INTERNAL MEDICINE, 2020, 180 (05) : 785 - +
  • [36] Cerebral Embolic Protection and Stroke-Related Mortality Following Transcatheter Aortic Valve Replacement
    Isogai, Toshiaki
    Bansal, Agam
    Vanguru, Husitha Reddy
    Agrawal, Ankit
    Shekhar, Shashank
    Puri, Rishi
    Reed, Grant W.
    Krishnaswamy, Amar
    Uchino, Ken
    Kapadia, Samir R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (05) : 569 - 571
  • [37] Cerebral Embolic Protection in Valve-inValve Transcatheter Aortic Valve Replacement
    Shekhar, Shashank
    Krishnaswamy, Amar
    Reed, Grant
    Puri, Rishi
    Yun, James
    Kapadia, Samir
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 216 : 110 - 111
  • [38] Predictors and outcomes of patient-prosthesis mismatch after transcatheter aortic valve replacement
    Stamou, Sotiris C.
    Chen, Kai
    James, Taylor M.
    Rothenberg, Mark
    Kapila, Arvind
    Faber, Cristiano
    Nores, Marcos A.
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (02) : 360 - 366
  • [39] Incidence, Predictors, and Outcomes of Endocarditis After Transcatheter Aortic Valve Replacement in the United States
    Mentias, Amgad
    Girotra, Saket
    Desai, Milind Y.
    Horwitz, Phillip A.
    Rossen, James D.
    Saad, Marwan
    Panaich, Sidakpal
    Kapadia, Samir
    Sarrazin, Mary Vaughan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (17) : 1973 - 1982
  • [40] Predictors and clinical outcomes of poor symptomatic improvement after transcatheter aortic valve replacement
    Yoshijima, Nobuhiro
    Saito, Tetsuya
    Inohara, Taku
    Anzai, Atsushi
    Tsuruta, Hikaru
    Shimizu, Hideyuki
    Fukuda, Keiichi
    Naganuma, Toru
    Mizutani, Kazuki
    Yamawaki, Masahiro
    Tada, Norio
    Yamanaka, Futoshi
    Shirai, Shinichi
    Tabata, Minoru
    Ueno, Hiroshi
    Takagi, Kensuke
    Watanabe, Yusuke
    Yamamoto, Masanori
    Hayashida, Kentaro
    OPEN HEART, 2021, 8 (02):