Correcting heading errors in optically pumped magnetometers through microwave interrogation

被引:4
|
作者
Kiehl, C. [1 ,2 ,3 ]
Menon, T. S. [1 ,2 ,3 ]
Hewatt, D. P. [1 ,2 ,3 ,4 ]
Knappe, S. [4 ,5 ,6 ]
Thiele, T. [7 ]
Regal, C. A. [1 ,2 ,3 ]
机构
[1] NIST, JILA, Boulder, CO 80309 USA
[2] Univ Colorado, Boulder, CO 80309 USA
[3] Univ Colorado, Dept Phys, Boulder, CO 80309 USA
[4] Univ Colorado, Paul M Rady Dept Mech Engn, Boulder, CO 80309 USA
[5] FieldLine Med, Boulder, CO 80301 USA
[6] FieldLine Ind, Boulder, CO 80301 USA
[7] Zurich Instruments AG, CH-8005 Zurich, Switzerland
来源
PHYSICAL REVIEW APPLIED | 2024年 / 22卷 / 01期
关键词
RUBIDIUM; SEARCH; LASER; HE-3;
D O I
10.1103/PhysRevApplied.22.014005
中图分类号
O59 [应用物理学];
学科分类号
摘要
We demonstrate how to measure in situ for heading errors of optically pumped magnetometers (OPMs) in the challenging parameter regime of compact vapor cells with imperfect optical pumping and high buffer gas pressure. For this, we utilize microwave-driven Ramsey and Rabi frequency spectroscopy (FS) to independently characterize scalar heading errors in free-induction-decay (FID) signals. Both of these approaches suppress 5-nT inaccuracies in geomagnetic fields caused by nonlinear Zeeman shifts in FID measurements to below 0.6 nT. For Ramsey FS, we implement short periods of microwave interrogation within a pi/2-tR-3 pi/2 Ramsey interferometry sequence, effectively circumventing systematic errors from off-resonant driving. Conversely, Rabi FS leverages an atom-microwave Hamiltonian for accurate modeling of Rabi oscillation frequencies, achieving a measurement precision down to 80 pT/./Hz that is limited primarily by technical microwave noise. We show that the fundamental sensitivity of Rabi FS is 30 pT/./Hz with our vapor cell parameters through a Cram & eacute;r-Rao lower-bound analysis. This work paves the way for future investigations into the accuracy of hyperfine structure magnetometry and contributes to the broader applicability of OPMs in fields ranging from navigation and geophysics to space exploration and unexploded ordinance detection, where heading error mitigation is essential.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] OPTICALLY PUMPED ATOMIC MAGNETOMETERS AFTER 3 DECADES
    ALEXANDROV, EB
    BONCHBRUEVICH, VA
    OPTICAL ENGINEERING, 1992, 31 (04) : 711 - 717
  • [22] Optically pumped magnetometers enable a new level of biomagnetic measurements
    Sander, Tilmann
    Jodko-Wladzinska, Anna
    Hartwig, Stefan
    Bruehl, Ruediger
    Middelmann, Thomas
    ADVANCED OPTICAL TECHNOLOGIES, 2020, 9 (05) : 247 - 251
  • [23] Muscle Fatigue Revisited - Insights From Optically Pumped Magnetometers
    Sometti, Davide
    Semeia, Lorenzo
    Baek, Sangyeob
    Chen, Hui
    Righetti, Giulia
    Dax, Juergen
    Kronlage, Cornelius
    Kirchgaessner, Milena
    Romano, Alyssa
    Heilos, Johanna
    Staber, Deborah
    Oppold, Julia
    Middelmann, Thomas
    Braun, Christoph
    Broser, Philip
    Marquetand, Justus
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [24] Distributed network of optically pumped magnetometers for space weather monitoring
    Mrozowski, Marcin S.
    Bell, Angus S.
    Griffin, Paul F.
    Hunter, Dominic
    Burt, David
    McGilligan, James P.
    Riis, Erling
    Beggan, Ciaran D.
    Ingleby, Stuart J.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [25] Optimizing longitudinal spin relaxation in miniaturized optically pumped magnetometers
    Mcwilliam, A. P.
    Dyer, S.
    Hunter, D.
    Mrozowski, M.
    Ingleby, S. J.
    Sharp, O.
    Burt, D. P.
    Griffin, P. F.
    Mcgilligan, J. P.
    Riis, E.
    PHYSICAL REVIEW APPLIED, 2024, 22 (06):
  • [26] Magnetic field imaging with microfabricated optically-pumped magnetometers
    Alem, Orang
    Mhaskar, Rahul
    Jimenez-Martinez, Ricardo
    Sheng, Dong
    LeBlanc, John
    Trahms, Lutz
    Sander, Tilmann
    Kitching, John
    Knappe, Svenja
    OPTICS EXPRESS, 2017, 25 (07): : 7849 - 7858
  • [27] Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils
    Iivanainen, Joonas
    Borna, Amir
    Zetter, Rasmus
    Carter, Tony R.
    Stephen, Julia M.
    McKay, Jim
    Parkkonen, Lauri
    Taulu, Samu
    Schwindt, Peter D. D.
    SENSORS, 2022, 22 (08)
  • [28] A TUNABLE FIBER LASER FOR APPLICATION TO HELIUM OPTICALLY PUMPED MAGNETOMETERS
    LEGARREC, A
    LEGER, JM
    PUREUR, D
    DOUAY, M
    BERNAGE, P
    NIAY, P
    DELEVAQUE, E
    JOURNAL DE PHYSIQUE IV, 1994, 4 (C4): : 695 - 698
  • [29] Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity
    Chen, Jieya
    Ye, Chaofeng
    Hou, Xingshen
    Niu, Yaqiong
    Sun, Limin
    SENSORS, 2025, 25 (02)
  • [30] Optically pumped magnetometers reveal fasciculations non-invasively
    Marquetand, Justus
    Middelmann, Thomas
    Dax, Juergen
    Baek, Sangyeob
    Sometti, Davide
    Grimm, Alexander
    Lerche, Holger
    Martin, Pascal
    Kronlage, Cornelius
    Siegel, Markus
    Braun, Christoph
    Broser, Philip
    CLINICAL NEUROPHYSIOLOGY, 2021, 132 (10) : 2681 - 2684