A comparison of full-field digital mammography (FFDM) with digital breast tomosynthesis (DBT) in the detection of microcalcifications by correlating mammographic and pathologic findings

被引:0
|
作者
Farghadani, Maryam [1 ]
Ghadiri-faraz, Bahar [1 ]
Riahinezhad, Maryam [1 ]
Sarami, Sahar [1 ]
机构
[1] Isfahan Univ Med Sci, Dept Radiol & Imaging, Esfahan, Iran
来源
IMMUNOPATHOLOGIA PERSA | 2024年 / 10卷 / 02期
关键词
Breast cancer; Breast microcalcification; Digital breast tomosynthesis; Full-field digital mammography; Screening; DIAGNOSTIC PERFORMANCE; CANCER; CALCIFICATIONS; COMBINATION; CLUSTERS;
D O I
10.34172/ipp.2024.40613
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Introduction: Breast micro-calcifications primarily represent benign conditions; they might be regarded as the earliest presentations of malignancies. As a well-known procedure, full-field digital mammography (FFDM) is a 2-dimensional (2-D) imaging modality most frequently used in breast cancer screening. DBT, i.e., digital breast tomosynthesis, on the other hand, is a 3- 3-dimensional (3-D) modality increasingly attracting the attention of researchers in the field for clinical applications. Objectives: The present study compares FFDM values against DBT technique data- considered a valuable means of screening breast cancers. Patients and Methods: This is a cross-sectional study conducted on 92 suspected breast cancer patients who underwent screening assessments using both FFDM and DBT. The breast calcification and density categories were identified according to ACR BI-RADS (American College of Radiology Breast Imaging- Reporting and Data System). The calcifications were categorized as benign (BIRADS 2 and 3) or malignant (BIRADS 4 and 5). The histopathological findings from the biopsied lesions were considered the gold standard for breast cancer diagnosis. The outcomes of FFDM and DBT were compared. Results: The total sensitivity of DBT in identifying benign versus malignant lesions was 96.7%. In the case of FFMD, the sensitivity value was 90.2%. On the other hand, both modalities revealed similar specificity, accounting for 8.7%. The area under the curve (AUC) accounted for 0.527 for DBT and 0.505 for FFDM. The overall agreement coefficient for the two radiologists in the identification of micro-calcifications accounted for 0.613 (95% CI: 0.394-0.823). This agreement coefficient for FFDM was 0.676 (95% CI: 0.412, 0.940), and the value for the DBT procedure was 0.517 (95% CI: 0.147, 0.887). Conclusion: According to the current study, DBT can be considered a powerful tool in screening and diagnosing microcalcifications such as FFDM in breast tissue. Although the sensitivity of DBT is remarkably high, its specificity is not justifiable.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Comparison of diagnostic performances in the evaluation of breast microcalcifications: synthetic mammography versus full-field digital mammography
    Kilic, Pinar
    Sendur, Halit Nahit
    Gultekin, Serap
    Gultekin, Isil Imge
    Cindil, Emetullah
    Cerit, Mahinur
    IRISH JOURNAL OF MEDICAL SCIENCE, 2022, 191 (04) : 1891 - 1897
  • [42] UTILIZATION AND COSTS OF DIGITAL BREAST TOMOSYNTHESIS OR BREAST ULTRASOUND IN CONJUNCTION WITH FULL-FIELD DIGITAL MAMMOGRAPHY
    Bonafede, M. M.
    Miller, J. D.
    Dabbous, F.
    Pohlman, S. K.
    Troeger, K. A.
    VALUE IN HEALTH, 2017, 20 (05) : A243 - A244
  • [43] Screening Mammography Findings From One Standard Projection Only in the Era of Full-Field Digital Mammography and Digital Breast Tomosynthesis
    Cohen, Ethan O.
    Tso, Hilda H.
    Phalak, Kanchan A.
    Mayo, Ray C.
    Leung, Jessica W. T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (02) : 445 - 451
  • [44] Digital Breast Tomosynthesis versus MRI as an Adjunct to Full-Field Digital Mammography for Preoperative Evaluation of Breast Cancer according to Mammographic Density
    Kim, Haejung
    Yang, So Yeon
    Ahn, Joong Hyun
    Ko, Eun Young
    Ko, Eun Sook
    Han, Boo-Kyung
    Choi, Ji Soo
    KOREAN JOURNAL OF RADIOLOGY, 2022, 23 (11) : 1031 - 1043
  • [45] Value and importance of full-field digital mammography (FFDM) for screening
    Grabbe, E
    Fischer, U
    Funke, M
    Hermann, KP
    Obenauer, S
    Baum, F
    RADIOLOGE, 2001, 41 (04): : 359 - 365
  • [46] Comparison of computer-aided detection of clustered microcalcifications in digital mammography and digital breast tomosynthesis
    Samala, Ravi K.
    Chan, Heang-Ping
    Lu, Yao
    Hadjiiski, Lubomir
    Wei, Jun
    Helvie, Mark
    MEDICAL IMAGING 2015: COMPUTER-AIDED DIAGNOSIS, 2015, 9414
  • [47] Two-View Digital Breast Tomosynthesis Screening with Synthetically Reconstructed Projection Images: Comparison with Digital Breast Tomosynthesis with Full-Field Digital Mammographic Images
    Skaane, Per
    Bandos, Andriy I.
    Eben, Ellen B.
    Jebsen, Ingvild N.
    Krager, Mona
    Haakenaasen, Unni
    Ekseth, Ulrika
    Izadi, Mina
    Hofvind, Solveig
    Gullien, Randi
    RADIOLOGY, 2014, 271 (03) : 655 - 663
  • [48] AN OBSERVER PERFORMANCE STUDY COMPARING THE INTERPRETATION OF FULL-FIELD DIGITAL MAMMOGRAPHY WITH DIGITAL BREAST TOMOSYNTHESIS
    Wasan, Rema K.
    Iqbal, Asif
    Evans, David R.
    Peacock, Clare
    Morel, Juliet C.
    Douiri, Abdel
    Michell, Michael J.
    EJC SUPPLEMENTS, 2010, 8 (06): : 32 - 32
  • [49] Size and Shape of Spherical Objects on Full-Field Digital Mammography and Digital Breast Tomosynthesis Images
    Yatake, Hidetoshi
    Sawai, Yuka
    Kozuka, Takahiro
    Takeda, Yoshihiro
    Kajihara, Mariko
    Katsuda, Toshizo
    Gotanda, Rumi
    Gotanda, Tatsuhiro
    Abe, Shuji
    Shimada, Makoto
    Tanki, Nobuyoshi
    Nishi, Toshio
    Inaji, Hideo
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 45 - 48
  • [50] Clinical performance of digital breast tomosynthesis versus full-field digital mammography: Preliminary results
    Gennaro, Gisella
    Baldan, Enrica
    Bezzon, Elisabetta
    La Grassa, Manuela
    Pescarini, Luigi
    di Maggio, Cosimo
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 477 - 482