Biomechanical Design Optimization of Distal Humerus Fracture Plates: A Review

被引:0
|
作者
Zdero, Radovan [1 ]
Brzozowski, Pawel [1 ]
Schemitsch, Emil H. [1 ,2 ]
机构
[1] Victoria Hosp, Orthopaed Biomech Lab, London, ON, Canada
[2] Western Univ, Div Orthopaed Surg, London, ON, England
关键词
biomechanics; distal humerus; fracture; optimization; plates; review; INTERNAL-FIXATION; PLATING SYSTEMS; LOCKING PLATES; PROPHYLACTIC FIXATION; RECONSTRUCTION PLATES; PROXIMAL HUMERUS; IMPLANT FAILURE; BONE; PARALLEL; STABILITY;
D O I
10.1155/2024/6015794
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The goal of this article was to review studies on distal humerus fracture plates (DHFPs) to understand the biomechanical influence of systematically changing the plate or screw variables. The problem is that DHFPs are commonly used surgically, although complications can still occur, and it is unclear if implant configurations are always optimized using biomechanical criteria. A systematic search of the PubMed database was conducted to identify English-language biomechanical optimization studies of DHFPs that parametrically altered plate and/or screw variables to analyze their influence on engineering performance. Intraarticular and extraarticular fracture (EAF) data were separated and organized under commonly used biomechanical outcome metrics. The results identified 52 eligible DHFP studies, which evaluated various plate and screw variables. The most common plate variables evaluated were geometry, hole type, number, and position. Fewer studies assessed screw variables, with number and angle being the most common. However, no studies examined nonmetallic materials for plates or screws, which may be of interest in future research. Also, articles used various combinations of biomechanical outcome metrics, such as interfragmentary fracture motion, bone, plate, or screw stress, number of loading cycles to failure, and overall stiffness (Os) or failure strength (Fs). However, no study evaluated the bone stress under the plate to examine bone "stress shielding," which may impact bone health clinically. Surgeons treating intraarticular and extraarticular distal humerus fractures should seriously consider two precontoured, long, thick, locked, and parallel plates that are secured by long, thick, and plate-to-plate screws that are located at staggered levels along the proximal parts of the plates, as well as an extra transfracture plate screw. Also, research engineers could improve new studies by perusing recommendations in future work (e.g., studying alternative nonmetallic materials or "stress shielding"), clinical ramifications (e.g., benefits of locked plates), and study quality (e.g., experimental validation of computational studies).
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Distal Humerus Fracture Malunion in Adults: A Case Report and a Review of the Literature
    Stavrakakis, Ioannis M.
    Ntontis, Zisis
    Kastritsi, Olga
    Chaniotakis, Constantinos
    Alpantaki, Kalliopi
    Kastanis, Grigorios
    CASE REPORTS IN ORTHOPEDICS, 2022, 2022
  • [22] OPEN COMMINUTED FRACTURE OF DISTAL HUMERUS
    AUFRANC, OE
    JONES, WN
    BIERBAUM, BE
    MITAL, M
    MACAUSLA.WR
    BARR, JS
    REIDY, JA
    LOWELL, JD
    ROWE, CR
    CAVE, EF
    RISENBOR.EJ
    BROWN, T
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 204 (05): : 387 - &
  • [23] Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis
    Lee, Jung-Soo
    Kim, Kwang Gi
    Yoon, Yong-Cheol
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [24] Transphyseal Fracture of the Distal Humerus in a Neonate
    Baker, Annalee
    Methratta, Sosamma T.
    Choudhary, Arabinda K.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2011, 12 (02) : 173 - 173
  • [25] Biomechanical design of a new proximal humerus fracture plate using alternative materials
    Islam, Sabrina
    Dembowski, Mitchell
    Schemitsch, Emil H.
    Bougherara, Habiba
    Bagheri, Z. Shaghayegh
    Zdero, Radovan
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024,
  • [26] Comparison of different distal radius dorsal and volar fracture fixation plates: A biomechanical study
    Osada, D
    Viegas, SF
    Shah, MA
    Morris, RP
    Patterson, RM
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (01): : 94 - 104
  • [27] A biomechanical comparison of plate configuration in distal humerus fractures
    Arnander, Magnus W. T.
    Reeves, Alexander
    MacLeod, Iain A. R.
    Pinto, Thomas M.
    Khaleel, Arshad
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (05) : 332 - 336
  • [28] Biomechanical Evaluation of the Fixation Methods for Transcondylar Fracture of the Humerus: ONI Plate Versus Conventional Plates and Screws
    Shimamura, Yasunori
    Nishida, Keiichiro
    Imatani, Junya
    Noda, Tomoyuki
    Hashizume, Hiroyuki
    Ohtsuka, Aiji
    Ozaki, Toshifumi
    ACTA MEDICA OKAYAMA, 2010, 64 (02) : 115 - 120
  • [29] Distal humerus fracture-extensile approaches
    Beeres, F. J. P.
    Oehme, F.
    Babst, R.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2017, 29 (02): : 115 - 124
  • [30] Biomechanical considerations in the design of patient-specific fixation plates for the distal radius
    G. Caiti
    J. G. G. Dobbe
    E. Bervoets
    M. Beerens
    S. D. Strackee
    G. J. Strijkers
    G. J. Streekstra