Comparison of ADNEX Model with GI-RADS Ultrasound Scoring System in Evaluation of Adnexal Mass

被引:0
|
作者
Parveen, Nazia [1 ]
Gupta, Bindiya [1 ]
Tandon, Anupama [2 ]
Gogoi, Priyanka [3 ]
机构
[1] UCMS & GTB Hosp, Dept Obstet & Gynaecol, Delhi, India
[2] UCMS & GTB Hosp, Dept Radiodiag, Delhi, India
[3] AIIMS Guwahati, Dept Pathol, Gauhati, Assam, India
关键词
ADNEX; Ultrasound; Neoplasia; Doppler; Malignancy; Biopsy;
D O I
10.1007/s13224-024-02000-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Purpose of the study This study aimed to evaluate and compare the diagnostic accuracy of two ultrasound scoring systems, Assessment of Different Neoplasias in the Adnexa (ADNEX) Model and Gynecology Imaging Reporting and Data System (GI-RADS), for the preoperative assessment of adnexal masses taking histopathology as gold standard. Methods This analytical study assessed 60 patients of age > 14 years with adnexal masses, planned for surgery. Ultrasound assessment and risk categorization according to ADNEX and GI-RADS were performed 2-3 days prior to surgery. Histopathology was used as a reference standard for the calculation of validity of two ultrasound scoring systems for diagnosis of adnexal masses. Results Out of 60 women (mean age, 35.52 +/- 13.86 years; range, 16-70 years) with adnexal masses, 24 were malignant and 36 were benign. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for the ADNEX model were 87.50%, 91.7%, 87.50%, 91.7% and 90.0%, respectively. The sensitivity, specificity, PPV, NPV and accuracy of the GI-RADS category were 95.8%, 61.1%, 62.2%, 95.7% and 75.0%, respectively. The diagnostic performance of the ADNEX model was better as compared to GI-RADS in terms of specificity and positive predictive value with a significant difference (p < 0.05). The area under curve (AUC) was 0.957 and 0.919 for ADNEX and GI-RADS, respectively (p = 0.252). Conclusion Although both ADNEX and GI-RADS systems had satisfactory diagnostic performances and high negative predictive values, the ADNEX model showed better specificity and positive predictive value in comparison with GI-RADS.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Application of Ultrasound Scores (Subjective Assessment, Simple Rules Risk Assessment, ADNEX Model, O-RADS) to Adnexal Masses of Difficult Classification
    Pelayo, Mar
    Sancho-Sauco, Javier
    Sanchez-Zurdo, Javier
    Perez-Mies, Belen
    Abarca-Martinez, Leopoldo
    Cancelo-Hidalgo, Ma Jesus
    Sainz-Bueno, Jose Antonio
    Alcazar, Juan Luis
    Pelayo-Delgado, Irene
    [J]. DIAGNOSTICS, 2023, 13 (17)
  • [22] The diagnostic performance of ultrasound in the diagnosis of indeterminate adnexal masses based on the O-RADS US scoring system
    Tantawy, Heba Fathy Ahmad
    Ebrahim, Saeed Abdel Monem
    Kamal, Marwa Rashad Ahmad
    Hassan, Rania Mostafa
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [23] The diagnostic performance of ultrasound in the diagnosis of indeterminate adnexal masses based on the O-RADS US scoring system
    Heba Fathy Ahmad Tantawy
    Saeed Abdel Monem Ebrahim
    Marwa Rashad Ahmad Kamal
    Rania Mostafa Hassan
    [J]. Egyptian Journal of Radiology and Nuclear Medicine, 55
  • [24] Re: "Diagnostic Accuracies of the Ultrasound and Magnetic Resonance Imaging ADNEX Scoring Systems for Ovarian Adnexal Mass: Systematic Review and Meta-Analysis"
    Van Calster, Ben
    Bourne, Tom
    Froyman, Wouter
    Timmerman, Dirk
    Valentin, Lil
    [J]. ACADEMIC RADIOLOGY, 2021, 28 (11) : 1643 - 1644
  • [25] Editorial for "Validity and Reproducibility of ADNEX MR SCORING System in Diagnosis of Sonographically Indeterminate Adnexal Masses"
    Thomassin-Naggara, Isabelle
    Rockall, Andrea
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (02) : 640 - 641
  • [26] Comparison of O-RADS with the ADNEX model and IOTA SR for risk stratification of adnexal lesions: a systematic review and meta-analysis
    Han, Jing
    Wen, Jing
    Hu, Wei
    [J]. FRONTIERS IN ONCOLOGY, 2024, 14
  • [27] Accuracy of the ADNEX MR scoring system based on a simplified MRI protocol for the assessment of adnexal masses
    Pereira, Patrick N.
    Sarian, Luis O.
    Yoshida, Adriana
    Araujo, Karla G.
    Barros, Ricardo H. O.
    Baiao, Ana C.
    Parente, Daniella B.
    Derchain, Sophie
    [J]. DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2018, 24 (02) : 63 - 71
  • [28] Estimating risk of malignancy in adnexal masses: external validation of the ADNEX model and comparison with other frequently used ultrasound methods
    Meys, E. M. J.
    Jeelof, L. S.
    Achten, N. M. J.
    Slangen, B. F. M.
    Lambrechts, S.
    Kruitwagen, R. F. P. M.
    Van Gorp, T.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2017, 49 (06) : 784 - 792
  • [29] Comparative Study of the Efficacy of the Ovarian-Adnexa Reporting and Data System Ultrasound Combined With Contrast-Enhanced Ultrasound and the ADNEX MR Scoring System in the Diagnosis of Adnexal Masses
    Wang, Ting
    Cui, Wenjun
    Nie, Fang
    Huang, Xiao
    Huang, Lele
    Liu, Luping
    Zhu, Yangyang
    Zheng, Rongfang
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (09): : 2072 - 2080
  • [30] Evaluation of new scoring system to diferntiate between benign and malignant adnexal mass
    Uma, Singh
    Neera, Kohli
    Nisha
    Ekta
    [J]. JOURNAL OF OBSTETRICS AND GYNECOLOGY OF INDIA, 2006, 56 (02): : 162 - 165