Validation of a Suprasystolic Cuff System for Static and Dynamic Representation of the Central Pressure Waveform

被引:1
|
作者
Tamborini, Alessio [1 ]
Gharib, Morteza [1 ]
机构
[1] CALTECH, Dept Med Engn, 1200 E Calif Blvd, Pasadena, CA 91125 USA
来源
关键词
cardiovascular dynamics; central pressure; cuff-based device; dynamic pulse waveform calibration; pulse waveform analysis; CENTRAL BLOOD-PRESSURE; PREDICTS CARDIOVASCULAR EVENTS; VENTRICULAR EJECTION TIME; AUGMENTATION INDEX; PULSE PRESSURE; ARTERIAL STIFFNESS; AORTIC PRESSURE; CARDIAC-OUTPUT; BRACHIAL CUFF; UPPER ARM;
D O I
10.1161/JAHA.123.033290
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Noninvasive pulse waveform analysis is valuable for central cardiovascular assessment, yet controversies persist over its validity in peripheral measurements. Our objective was to compare waveform features from a cuff system with suprasystolic blood pressure hold with an invasive aortic measurement. METHODS AND RESULTS: This study analyzed data from 88 subjects undergoing concurrent aortic catheterization and brachial pulse waveform acquisition using a suprasystolic blood pressure cuff system. Oscillometric blood pressure (BP) was compared with invasive aortic systolic BP and diastolic BP. Association between cuff and catheter waveform features was performed on a set of 15 parameters inclusive of magnitudes, time intervals, pressure-time integrals, and slopes of the pulsations. The evaluation covered both static (subject-averaged values) and dynamic (breathing-induced fluctuations) behaviors. Peripheral BP values from the cuff device were higher than catheter values (systolic BP-residual, 6.5 mm Hg; diastolic BP-residual, 12.4 mm Hg). Physiological correction for pressure amplification in the arterial system improved systolic BP prediction (r(2)=0.83). Dynamic calibration generated noninvasive BP fluctuations that reflect those invasively measured (systolic BP Pearson R=0.73, P<0.001; diastolic BP Pearson R=0.53, P<0.001). Static and dynamic analyses revealed a set of parameters with strong associations between catheter and cuff (Pearson R>0.5, P<0.001), encompassing magnitudes, timings, and pressure-time integrals but not slope-based parameters. CONCLUSIONS: This study demonstrated that the device and methods for peripheral waveform measurements presented here can be used for noninvasive estimation of central BP and a subset of aortic waveform features. These results serve as a benchmark for central cardiovascular assessment using suprasystolic BP cuff-based devices and contribute to preserving system dynamics in noninvasive measurements.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Validation Study to Determine the Accuracy of Central Blood Pressure Measurement Using the Sphygmocor Xcel Cuff Device
    Schultz, Martin G.
    Picone, Dean S.
    Armstrong, Matthew K.
    Black, J. Andrew
    Dwyer, Nathan
    Roberts-Thomson, Philip
    Sharman, James E.
    HYPERTENSION, 2020, 76 (01) : 244 - 250
  • [22] VALIDATION OF AMBULATORY CUFF-BASED DEVICES FOR CENTRAL AORTIC BLOOD PRESSURE AND ARTERIAL STIFFNESS MEASUREMENT
    Butlin, M.
    Al Qahtani
    Quasem, A.
    Avolio, A. P.
    HYPERTENSION, 2015, 65 (05) : E34 - E34
  • [23] VALIDATION ASSESSMENT OF A CUFF-BASED CENTRAL BLOOD PRESSURE DEVICE ACCORDING TO ARTERY SOCIETY RECOMMENDATIONS
    Bui, Tan
    Picone, Dean
    Kosmala, Wojciech
    Kosowski, Michal
    Zachwyc, Jowita
    Pucci, Giacomo
    Schultz, Martin
    Black, Andrew
    Dwyer, Nathan
    Roberts-Thomson, Phillip
    Adams, Heath
    Curcio, Rosa
    Arrivi, Alessio
    Paleri, Sarang
    Sharman, James
    JOURNAL OF HYPERTENSION, 2024, 42 (SUPPL 3)
  • [24] Validation of the central blood pressure estimation by the SphygmoCor system in Chinese
    Zuo, Jun-Li
    Li, Yan
    Yan, Zi-Jun
    Zhang, Rui-Yan
    Shen, Wei-Feng
    Zhu, Ding-Liang
    Gao, Ping-Jin
    Chu, Shao-Li
    BLOOD PRESSURE MONITORING, 2010, 15 (05) : 268 - 274
  • [25] Validation of the central blood pressure estimation by the SphygmoCor system in Chinese
    Zuo, Jun-Li
    Chu, Shao-Li
    Li, Yan
    Yan, Zi-Jun
    Zhang, Rui-Yan
    Shen, Wei-Feng
    Gao, Ping-Jin
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 137 : S18 - S18
  • [26] CENTRAL CONTROL-SYSTEM TRAINING THROUGH STATIC AND DYNAMIC SIMULATION
    HALL, EE
    MOSS, DG
    NORRIS, CS
    PETERSON, HD
    NAVAL ENGINEERS JOURNAL, 1980, 92 (02) : 196 - 206
  • [27] A New Method to Estimate Aortic Pulse Wave Velocity and Central Systolic Blood Pressure by Measuring Brachial Cuff Pulse Waveform
    Shiina, Kazuki
    Tomiyama, Hirofumi
    Odaira, Mari
    Yoshida, Masanobu
    Yamashina, Akira
    Kobayashi, Tatsuya
    Fujii, Kenji
    Ogura, Toshihiko
    CIRCULATION, 2011, 124 (21)
  • [28] Footwork Pro System Reproducibility of Static and Dynamic Plantar Pressure Indicators
    Rogerio, Fernando Raphael
    Guedes, Dartagnan Pinto
    JOURNAL OF CHIROPRACTIC MEDICINE, 2023, 22 (01) : 45 - 51
  • [29] Nonlinear Dynamic Modeling of Blood Pressure Waveform: Towards an Accurate Cuffless Monitoring System
    Landry, Cederick
    Peterson, Sean D.
    Arami, Arash
    IEEE SENSORS JOURNAL, 2020, 20 (10) : 5368 - 5378
  • [30] DYNAMIC VERSUS STATIC PRESSURE EVOKED POTENTIALS. INDICATIONS OF CENTRAL MIDDLE EAR PRESSURE CONTROL IN HUMANS
    Sami, Saber A. K.
    Gaihede, Michael
    Nielsen, Lars-Gustav
    Drewes, Asbjorn M.
    MIDDLE EAR MECHANICS IN RESEARCH AND OTOLOGY, 2007, : 36 - +