Validation of a Suprasystolic Cuff System for Static and Dynamic Representation of the Central Pressure Waveform

被引:1
|
作者
Tamborini, Alessio [1 ]
Gharib, Morteza [1 ]
机构
[1] CALTECH, Dept Med Engn, 1200 E Calif Blvd, Pasadena, CA 91125 USA
来源
关键词
cardiovascular dynamics; central pressure; cuff-based device; dynamic pulse waveform calibration; pulse waveform analysis; CENTRAL BLOOD-PRESSURE; PREDICTS CARDIOVASCULAR EVENTS; VENTRICULAR EJECTION TIME; AUGMENTATION INDEX; PULSE PRESSURE; ARTERIAL STIFFNESS; AORTIC PRESSURE; CARDIAC-OUTPUT; BRACHIAL CUFF; UPPER ARM;
D O I
10.1161/JAHA.123.033290
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Noninvasive pulse waveform analysis is valuable for central cardiovascular assessment, yet controversies persist over its validity in peripheral measurements. Our objective was to compare waveform features from a cuff system with suprasystolic blood pressure hold with an invasive aortic measurement. METHODS AND RESULTS: This study analyzed data from 88 subjects undergoing concurrent aortic catheterization and brachial pulse waveform acquisition using a suprasystolic blood pressure cuff system. Oscillometric blood pressure (BP) was compared with invasive aortic systolic BP and diastolic BP. Association between cuff and catheter waveform features was performed on a set of 15 parameters inclusive of magnitudes, time intervals, pressure-time integrals, and slopes of the pulsations. The evaluation covered both static (subject-averaged values) and dynamic (breathing-induced fluctuations) behaviors. Peripheral BP values from the cuff device were higher than catheter values (systolic BP-residual, 6.5 mm Hg; diastolic BP-residual, 12.4 mm Hg). Physiological correction for pressure amplification in the arterial system improved systolic BP prediction (r(2)=0.83). Dynamic calibration generated noninvasive BP fluctuations that reflect those invasively measured (systolic BP Pearson R=0.73, P<0.001; diastolic BP Pearson R=0.53, P<0.001). Static and dynamic analyses revealed a set of parameters with strong associations between catheter and cuff (Pearson R>0.5, P<0.001), encompassing magnitudes, timings, and pressure-time integrals but not slope-based parameters. CONCLUSIONS: This study demonstrated that the device and methods for peripheral waveform measurements presented here can be used for noninvasive estimation of central BP and a subset of aortic waveform features. These results serve as a benchmark for central cardiovascular assessment using suprasystolic BP cuff-based devices and contribute to preserving system dynamics in noninvasive measurements.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Evaluation of a Brachial Cuff and Suprasystolic Waveform Algorithm Method to Noninvasively Derive Central Blood Pressure
    Costello, Benedict T.
    Schultz, Martin G.
    Black, J. Andrew
    Sharman, James E.
    AMERICAN JOURNAL OF HYPERTENSION, 2015, 28 (04) : 480 - 486
  • [2] Optimization and validation of a suprasystolic brachial cuff-based method for noninvasively estimating central aortic blood pressure
    Zhang, Xujie
    Wang, Yue
    Yin, Zhaofang
    Liang, Fuyou
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (03)
  • [3] Invasive validation of central blood pressure measurements using a suprasystolic monitor
    Scalia, A.
    Ghafari, C.
    Scott, R. F.
    Rochd, E. M.
    Caulier, F.
    Phillips, R.
    Carlier, S. G.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [4] Numerical validation of a suprasystolic brachial cuff-based method for estimating aortic pressure
    Liang, Fuyou
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 1053 - 1062
  • [5] Estimation of Aortic Pressure Waveform via Dynamic System Modeling between Aortic Pressure and Cuff Oscillometric Signal
    Hong, Junki
    Jeong, Jae-Hak
    Lee, Bomi
    Min, Changhee
    Park, Yong-Hwa
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2024, 48 (04) : 285 - 288
  • [6] Estimation of central aortic pressure waveform features derived from the brachial cuff volume displacement waveform
    Butlin, Mark
    Qasem, Ahmad
    Avolio, Alberto P.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2591 - 2594
  • [7] Validation of the Tekscan System for static and dynamic pressure measurements in the human femorotibial joint
    Wirz, D
    Becker, R
    Li, SF
    Friederich, NF
    Müller, W
    BIOMEDIZINISCHE TECHNIK, 2002, 47 (7-8): : 195 - 201
  • [8] A new invasive validation method for non-invasive central blood pressure measurement using a suprasystolic sphygmomanometer
    Scalia, Alessandro
    Carlier, Stephane
    Thayse, Kathleen
    ACTA CARDIOLOGICA, 2019, 74 : 66 - 67
  • [9] Two-cuff noninvasive blood pressure waveform monitoring system for dynamic blood vessel characteristic study
    Hu, Weichi
    Chang, Feng-Shuo
    Jo, Shih-Hao
    Lin, Yon-Rong
    Shyu, Liang-Yu
    1ST TRANSDISCIPLINARY CONFERENCE ON DISTRIBUTED DIAGNOSIS AND HOME HEALTHCARE, CONFERENCE PROCEEDINGS, 2006, : 87 - +
  • [10] A new invasive validation method for non-invasive central blood pressure measurement using a suprasystolic sphygmomanometer
    Scalia, A.
    Thayse, K.
    Ghafari, C.
    Delmotte, P.
    Brunner, P.
    Carlier, S. G.
    EUROPEAN HEART JOURNAL, 2019, 40 : 400 - 400