Enhanced nitrate removal from groundwater using a conductive spacer in flow-electrode capacitive deionization

被引:0
|
作者
Hongjie Guo [1 ,2 ]
Qiang Wei [2 ]
Yangyang Wu [2 ]
Wei Qiu [3 ]
Hongliang Li [1 ]
Changyong Zhang [2 ]
机构
[1] College of Mining Engineering, Taiyuan University of Technology
[2] CAS Key Laboratory of Urban Pollutant Conversion, Department of Environmental Science and Engineering, University of Science and Technology of China
[3] CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, University of Science and Technology of
关键词
D O I
暂无
中图分类号
TQ028 [分离过程]; X523 [地下水];
学科分类号
摘要
Flow-electrode capacitive deionization(FCDI) represents a promising approach for ion separation from aqueous solutions. However, the optimization of spacer, particularly for nitrate-contaminated groundwater systems, has often been overlooked. This research comprehensively investigates the influence of using a conductive(carbon cloth, CC) spacer on nitrate removal performance within FCDI system, comparing it to a non-conductive(nylon net, NN) spacer. In both CC and NN FCDI systems, it is unsurprisingly that nitrate removal efficiency improved notably with the increasing current density and hydraulic retention time(HRT). Interestingly, the specific energy consumption(SEC) for nitrate removal did not show obvious fluctuations when the current density and HRT varied in both systems. Under the auspiciously optimized process parameters, CC-FCDI attained a 20% superior nitrate removal efficiency relative to NN-FCDI, accompanied by a notably diminished SEC for CC-FCDI, registering at a mere 28% of NN-FCDI. This great improvement can be primarily attributed to the decrement in FCDI internal resistance after using conductive spacer, which further confirmed by electrochemical tests such as linear sweep voltammetry(LSV)and electrochemical impedance spectroscopy(EIS). Upon prolonged continuous nitrate removal at the optimized conditions, the CC-FCDI system achieved a consistent 90% nitrate removal efficiency with a low SEC of 2.7–7.8 k Wh/kg NO3-N, underscoring its steady performance. Overall, this study highlights the pivotal importance of careful spacer design and optimization in realizing energy-efficient groundwater treatment via FCDI.
引用
收藏
页码:406 / 409
页数:4
相关论文
共 50 条
  • [21] Continuous Lithium Extraction from Aqueous Solution Using Flow-Electrode Capacitive Deionization
    Ha, Yuncheol
    Jung, Hye Bin
    Lim, Hyunseung
    Jo, Pil Sung
    Yoon, Hana
    Yoo, Chung-Yul
    Tuan Kiet Pham
    Ahn, Wook
    Cho, Younghyun
    ENERGIES, 2019, 12 (15)
  • [22] Nickel removal from aqueous solutions using flow-electrode capacitive deionization (Optimization by Response Surface Methodology (RSM))
    Pelarti, Mahdieh Mohammadi
    Mirbagheri, Seyed Ahmad
    Dehghan, Khadijeh
    Alam, Mahdi
    WATER SCIENCE AND TECHNOLOGY, 2022, 86 (06) : 1299 - 1307
  • [23] Efficient phosphorus removal from ultra-low concentration wastewater by flow-electrode capacitive deionization
    Zhang, Jie
    Xu, Bin
    Wang, Zheng
    Gan, Yonghai
    Chen, Zhihao
    Zhang, Zihao
    Jiang, Kaixiang
    Han, Zilong
    Zhang, Kegui
    Yang, Wenzhong
    SEPARATION AND PURIFICATION TECHNOLOGY, 2024, 341
  • [24] Effective and continuous removal of Cr(VI) from brackish wastewater by flow-electrode capacitive deionization (FCDI)
    Dong, Yi
    Xing, Wenle
    Luo, Kunyue
    Zhang, Jing
    Yu, Jiaqi
    Jin, Wanwan
    Wang, Jiajia
    Tang, Wangwang
    JOURNAL OF CLEANER PRODUCTION, 2021, 326
  • [25] The electrode materials in flow-electrode capacitive deionization desalination: a mini review
    Jiang, Yu-Xin
    Zhang, Wen-Chao
    Deng, Yu-Mei
    Cao, Jing-Xiao
    Asare, Justice Annor
    Alhassan, Sikpaam Issaka
    Zhang, Fang-Li
    Wang, Ping
    Wang, Hai-Ying
    RARE METALS, 2025,
  • [26] Salt removal from brackish waters by redox-active flow-electrode capacitive deionization (FCDI)
    Waite, Trevor
    Ma, Jinxing
    He, Di
    Tang, Wangwang
    Kovalsky, Peter
    He, Calvin
    Zhang, Changyong
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [27] Enhanced Desalination Performance by a Novel Archimedes Spiral Flow Channel for Flow-Electrode Capacitive Deionization
    Zhang, Xinyuan
    Zhou, Jian
    Zhou, Hongjian
    Zhang, Haimin
    Zhao, Huijun
    ACS ES&T ENGINEERING, 2022, 2 (07): : 1250 - 1259
  • [28] Effective and continuous removal of Cr(VI) from brackish wastewater by flow-electrode capacitive deionization (FCDI)
    Dong, Yi
    Xing, Wenle
    Luo, Kunyue
    Zhang, Jing
    Yu, Jiaqi
    Jin, Wanwan
    Wang, Jiajia
    Tang, Wangwang
    Journal of Cleaner Production, 2021, 326
  • [29] Enhancing Brackish Water Desalination using Magnetic Flow-electrode Capacitive Deionization
    Xu, Longqian
    Peng, Shuai
    Mao, Yunfeng
    Zong, Yang
    Zhang, Xiaomeng
    Wu, Deli
    Water Research, 2022, 216
  • [30] Exploring flow-electrode capacitive deionization: An overview and new insights
    Tauk, Myriam
    Sistat, Philippe
    Habchi, Roland
    Cretin, Marc
    Zaviska, Francois
    Bechelany, Mikhael
    DESALINATION, 2025, 597