Indoor biology pollution control based on system-based humidity priority control strategy

被引:0
|
作者
刘亚昱
谢慧
石博强
机构
[1] SchoolofCivilandEnvironmentEngineering,UniversityofScienceandTechnologyBeijing
关键词
D O I
暂无
中图分类号
TU834 [通风、除尘、空气净化、除湿];
学科分类号
摘要
Indoor biological contamination and HVAC system secondary contamination problems caused wide public concerns. Biological contamination control will be the next step to achieve better IAQ. The most efficient and safe way to control biological contamination was to limit relative humidity in HVAC system and conditioned environment in the range that is more unsuitable for microorganism to survive. In this paper,by referring to bio-clean project experiences,a system-based humidity priority control manner came into being by lowering outdoor air humidity ratio to eliminate all indoor latent load and using self recirculation units to bear indoor sensible load. Based on the whole-course residue humidity contaminant control concept,dynamic step models for coil and conditioned zone were developed to describe mass and energy conservation and transformation processes. Then,HVAC system and conditioned zone dynamic models were established on LabVIEW+Matlab platform to investigate optimized regulation types,input signatures and control logics. Decoupling between cooling and dehumidification processes can be achieved and a more simplified and stable control system can be acquired by the system-based humidity priority control strategy. Therefore,it was a promising way for controlling biological pollution in buildings in order to achieve better IAQ.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 50 条
  • [41] Switching control strategy for greenhouse temperature- humidity system based on prediction modeling: A simulation study
    Xu, Zhenfeng
    Chen, Junjie
    Journal of Engineering and Technological Sciences, 2017, 49 (05): : 689 - 703
  • [42] Flowers Temperature and Humidity Control System based on Applied Mechanics
    Shao WenMian
    Li Haitao
    Jin LiHong
    GREEN POWER, MATERIALS AND MANUFACTURING TECHNOLOGY AND APPLICATIONS II, 2012, 214 : 644 - +
  • [43] BUILDING PRESSURIZATION CONTROL AS AN INDOOR POLLUTION MITIGATION STRATEGY IN RESIDENTIAL DWELLINGS
    HARPER, JP
    NAGDA, NL
    PURCELL, GG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 192 : 91 - ENVR
  • [44] A novel metal-organic frameworks based humidity pump for indoor moisture control
    Hou, Pumin
    Zu, Kan
    Qin, Menghao
    Cui, Shuqing
    BUILDING AND ENVIRONMENT, 2021, 187
  • [45] Design of a Proportional-Control-Based Advanced Control Strategy for Independent Temperature and Humidity Control of a Pre-Cooled Desiccant Air Cooling System
    Demir, Mehmet Hakan
    Cetin, Sabri
    Haggag, Osama
    Demir, Habibe Gursoy
    Worek, William
    Premer, Jeffrey
    Pandelidis, Demis
    APPLIED SCIENCES-BASEL, 2022, 12 (19):
  • [46] Animal Building Temperature Control Strategy Based on Fuzzy Control System
    Wang Jianxin
    Gao Xianwei
    Sui Meili
    Li Xiuying
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 2402 - 2405
  • [47] MMC-DVR control system based on passivity control strategy
    Zhou Y.
    Cheng Q.
    Jiang C.
    Xie Y.
    Fu W.
    Ye P.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (10): : 275 - 280
  • [48] Optimal Control Strategy of Temperature Control Equipment Based on CPS System
    Wang, Chaoliang
    Liu, Wei
    Du, Yabin
    Li, Bin
    PROCEEDINGS OF 2022 12TH INTERNATIONAL CONFERENCE ON POWER, ENERGY AND ELECTRICAL ENGINEERING (CPEEE 2022), 2022, : 348 - 353
  • [49] Electric control loading system control strategy study based on LMI
    Wang, Yuping, 1600, Science and Engineering Research Support Society (07):
  • [50] A control strategy of heating system based on adaptive model predictive control
    Sha, Le
    Jiang, Ziwei
    Sun, Hejiang
    ENERGY, 2023, 273