Investigation on shear behavior of the interface between engineered cementitious composites and normal-strength concrete

被引:10
|
作者
Wu, Fangwen [1 ]
Ma, Yateng [1 ]
Cao, Jincheng [1 ]
Chen, Ao [1 ]
Li, Zirun [1 ]
机构
[1] Changan Univ, Sch Highway, Xian 710064, Peoples R China
基金
中国国家自然科学基金;
关键词
Shear strength; ECC-to-concrete interface; Push-out direct-shear test; Construction method of ECC mixture; Interfacial bonding methods; AFFECTING BOND; BEAMS; ECC; PERFORMANCE; MODEL;
D O I
10.1016/j.istruc.2024.106238
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Engineering cementitious composites (ECC), possessing excellent mechanical properties for good durability, can be applied to repair and strengthen reinforced concrete structures. In the present study, the interface shear behavior between ECC and normal-strength concrete was studied. Thirty bonded joint specimens were fabricated and subjected to push-out direct-shear tests. The construction methods of ECC mixture (precast and cast-inplace), ECC strength, and interface bonding methods (i.e., Epoxy resin, UHPC, cast-in-place ECC, cast-in-place ECC with chiseling, and bolts) were investigated. The results indicated that interface bonding methods have a significant influence on the failure modes and interface shear strength between ECC and existing concrete. There were three failure modes: interface debonding, interface debonding converted to concrete fracture, and concrete matrix destruction failure. Epoxy resin bonded specimens exhibited the highest shear strength, and cast-in-place ECC bonded specimens showed the lowest shear strength. Moreover, the shear performance of the ECC and the normal-strength concrete interface was analyzed in terms of interfacial shear strength and shear stiffness, bondslip curve, and shear transfer mechanism. Finally, an analytical model for estimating the interfacial shear strength considering the interfacial bonding methods was established, with its predictions having high accuracy.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Experimental investigation of the compressive strength of normal-strength air-entrained concrete at high temperatures
    Holan, Jakub
    Novak, Josef
    Muller, Petr
    Stefan, Radek
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 248 (248)
  • [32] Experimental Investigation of the Bond Performance at the Interface between Engineered Geopolymer Composites and Existing Concrete
    Li, Zhibin
    Tan, Jiaqi
    Ouyang, Ji
    Yu, Yongxin
    Li, Shibin
    Lin, Taoxin
    Liu, Runan
    Li, Wen
    BUILDINGS, 2024, 14 (06)
  • [33] Study on the interfacial shear performance between engineered cementitious composites and concrete after being subjected to high temperatures
    Shang, Xing-yan
    Xu, Fang-zheng
    Yu, Jiang-tao
    Li, Ling-zhi
    Lu, Zhou-dao
    JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [34] Interpretable machine learning models for predicting the bond strength between UHPC and normal-strength concrete
    Liu, Kaihua
    Wu, Tingrui
    Shi, Zhuorong
    Yu, Xiaoqing
    Lin, Youzhu
    Chen, Qian
    Jiang, Haibo
    MATERIALS TODAY COMMUNICATIONS, 2024, 40
  • [35] Effect of Roughness on the Bond Behavior between Ultrahigh-Performance Engineered Cementitious Composites and Old Concrete
    Zhang, Cong
    Wu, Lishan
    Yu, Zhihui
    Gu, Jiaming
    Ukrainczyk, Neven
    Cai, Jingming
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2023, 35 (08)
  • [36] Numerical analysis on damaged reinforced concrete shear wall repaired with engineered cementitious composites
    Yu, Jiangtao
    Chen, Jing
    Lu, Zhoudao
    Zhang, Yuanmiao
    Tongji Daxue Xuebao/Journal of Tongji University, 2015, 43 (02): : 175 - 180
  • [37] Seismic shear behavior of masonry walls strengthened with engineered cementitious composites (ECC)
    Wang, Hanpeng
    Yu, Jiangtao
    Dong, Fangyuan
    Jiang, Fangming
    Yu, Kequan
    JOURNAL OF BUILDING ENGINEERING, 2025, 104
  • [38] Shear Strength of Beams Made Using Hybrid Fiber-Engineered Cementitious Composites
    Alrefaei, Yazan
    Rahal, Khaldoun
    Maalej, Mohamed
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (01)
  • [39] Comparison of shear behaviour of engineered cementitious composite and normal concrete beams with different shear span lengths
    Alyousif, Ahmed
    Anil, Ozgur
    Sahmaran, Mustafa
    Lachemi, Mohamed
    Yildirim, Gurkan
    Ashour, Ashraf F.
    MAGAZINE OF CONCRETE RESEARCH, 2016, 68 (05) : 217 - 228
  • [40] Seismic behavior of normal-strength concrete-filled precast high-strength concrete centrifugal tube columns
    Zhang, Shaohua
    Zhang, Xizhi
    Xu, Shengbo
    Li, Xingqian
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (04) : 614 - 629