Traceability for AC Ripple Over DC Current

被引:2
|
作者
Giordano, Domenico [1 ]
Delle Femine, Antonio [2 ]
Gallo, Daniele [2 ]
Signorino, Davide [1 ]
机构
[1] INRIM, I-10135 Turin, Italy
[2] Univ Campania Luigi Vanvitelli, Dept Engn, I-81031 Aversa, Italy
关键词
Current measurement; Calibration; Standards; Windings; Uncertainty; Transformers; Systematics; dc power system; efficiency; power quality (PQ); ripple; traceability; POWER;
D O I
10.1109/TIM.2024.3385034
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Direct current (dc) is experiencing a new renaissance. The consolidated high-voltage direct current (HVdc), together with new medium voltage direct current (MVdc), and low-voltage direct current (LVdc) are more and more present in research and development projects. One of the relevant topics, associated with the usage of dc, is the ac ripple that unavoidably accompanies the dc signals. The interest in the measurement of this quantity is linked with the determination of the performance of dc energy meters for billing purposes. The on-line power quality (PQ) analysis, the verification of the capabilities of the filtering systems, and the accurate determination of losses associated with the transmission, distribution, and conversion of the electric energy by dc systems require accurate determination of the ac ripple. National metrology institutes (NMIs) provide traceability only for pure ac or pure dc current signals. To guarantee a high-quality standard for such measurements, the article proposes a novel methodology, named ALFO, for the traceable calibration of measuring systems with signals composed by dc with superimposed ac ripple. The calibration setup is based on a decoupling transformer (DeT) which has been specifically designed by a numerical tool. A detailed analysis and quantification of the systematic errors affecting the measurement and of uncertainty budget have been performed. The setup can calibrate current measuring systems up to 100 A (dc) with ac ripple up to 1% of the dc in the frequency range 300 Hz-150 kHz. Preliminary evaluation of the standard uncertainty, performed at maximum 40 A dc and 1 A ac up to 250 mu A /A in the range of 300 Hz-150 kHz.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] Development of a DC-Side Direct Current Controlled Active Ripple Filter for Eliminating the Double-Line-Frequency Current Ripple in a Single-Phase DC/AC Conversion System
    Chen, Ying-Chieh
    Chen, Liang-Rui
    Lai, Ching-Ming
    Lin, Yuan-Chih
    Kuo, Ting-Jung
    ENERGIES, 2020, 13 (18)
  • [22] A Single Phase AC/DC/AC Converter With Unified Ripple Power Decoupling
    Liu, Yonglu
    Sun, Yao
    Su, Mei
    Li, Xing
    Ning, Sijie
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (04) : 3204 - 3217
  • [23] DC Ripple Component Cancelation Method of Isolated AC-DC Converter with Matrix Converter for Input Current Harmonics Reduction
    Takuma, Shunsuke
    Kusaka, Keisuke
    Itoh, Jun-ichi
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 6754 - 6761
  • [24] A Current Ripple Cancellation Circuit for Electrolytic Capacitor-less AC-DC LED Driver
    Lee, Kuan-Wen
    Hsieh, Yi-Hsun
    Liang, Tsorng-Juu
    2013 TWENTY-EIGHTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2013), 2013, : 1058 - 1061
  • [25] Test Fixtures to Apply Variable DC Bias and AC Ripple Current for Reliability Testing of Electrolytic Capacitors
    Wang, Xuechao
    Karami, Marzieh
    Tallam, Rangarajan M.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (04) : 4073 - 4079
  • [26] A resonant DC-DC transformer with zero current ripple
    Abramovitz, A
    Smedley, K
    2005 IEEE 36th Power Electronic Specialists Conference (PESC), Vols 1-3, 2005, : 1299 - 1305
  • [27] A resonant DC-DC transformer with zero current ripple
    Abramovitz, Alexander
    Smedley, Keyue
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (06) : 2344 - 2351
  • [28] DC-link current analysis of three-phase 2L-VSI considering AC current ripple
    Li, Qiao
    Jiang, Dong
    IET POWER ELECTRONICS, 2018, 11 (01) : 202 - 211
  • [29] Hybrid cancellation of ripple disturbances arising in AC/DC converters
    Bisoffi, Andrea
    Zaccarian, Luca
    Da Lio, Mauro
    Carnevale, Daniele
    Abhangi, M.
    Abreu, P.
    Aftanas, M.
    Afzal, M.
    Aggarwal, K. M.
    Aho-Mantila, L.
    Ahonen, E.
    Aints, M.
    Airila, M.
    Albanese, R.
    Alegre, D.
    Alessi, E.
    Aleynikov, P.
    Alfier, A.
    Alkseev, A.
    Allan, P.
    Almaviva, S.
    Alonso, A.
    Alper, B.
    Alsworth, I.
    Alves, D.
    Ambrosino, G.
    Ambrosino, R.
    Amosov, V.
    Andersson, F.
    Andersson Sunden, E.
    Angelone, M.
    Anghel, A.
    Anghel, M.
    Angioni, C.
    Appel, L.
    Apruzzese, G.
    Arena, P.
    Ariola, M.
    Arnichand, H.
    Arnoux, G.
    Arshad, S.
    Ash, A.
    Asp, E.
    Asunta, O.
    Atanasiu, C. V.
    Austin, Y.
    Avotina, L.
    Axton, M. D.
    Ayres, C.
    Bachmann, C.
    AUTOMATICA, 2017, 77 : 344 - 352
  • [30] CURRENT RIPPLE EFFECT ON SUPERCONDUCTIVE DC CRITICAL CURRENT MEASUREMENTS
    GOODRICH, LF
    BRAY, SL
    CRYOGENICS, 1988, 28 (11) : 737 - 743