An automated insulin delivery system from pregestational care to postpartum in women with type 1 diabetes. Preliminary experience with telemedicine in 6 patients

被引:3
|
作者
Fresa, Raffaella [1 ]
Bitterman, Olimpia [2 ]
Cavallaro, Vincenzo [1 ]
Di Filippi, Marianna [1 ]
Dimarzo, Daniela [1 ]
Mosca, Carmela [1 ]
Nappi, Francesca [1 ]
Rispoli, Marilena [1 ]
Napoli, Angela [3 ,4 ,5 ]
机构
[1] Asl Salerno, Diabetol Outpatient Clin, Dist 63, Salerno, Italy
[2] San Paolo Hosp, Diabetol Unit, ASL Roma 4, Rome, Italy
[3] Israelitico Hosp, Rome, Italy
[4] Int Med Univ Unicamillus, Rome, Italy
[5] Cdc Santa Famiglia, Rome, Italy
关键词
Insulin pump; Pregnancy; Telemedicine; Type; 1; diabetes; CLOSED-LOOP; PREGNANT-WOMEN; HOME USE; MANAGEMENT;
D O I
10.1007/s00592-024-02315-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The use of most commercially available automated insulin delivery (AID) systems is off-label in pregnancy. However, an increasing number of women with type 1 diabetes (T1D) use such devices throughout pregnancy and delivery. We analysed the data of six women with T1D from a single centre (Diabetology Outpatient Clinic of District-63/Asl Salerno, Italy) who were able to start and maintain AID therapy with the MiniMed (TM) 780G (Medtronic, Minneapolis, MN, USA) throughout the pregestational care period, pregnancy, delivery, and postpartum. Methods We retrospectively collected data from six patients with T1D who received training and initiation on use of the MiniMed (TM) 780G and attended follow-up visits throughout pregnancy (these visits were virtual because of the COVID-19 pandemic). All patients maintained their devices in the closed-loop setting throughout pregnancy and during labour and delivery. We analysed data from the pregestational phase to the first 30 days postpartum. Results All patients achieved the recommended metabolic goals before conception [median time in range (TIR) of 88% for 70-180 mg/dL; median pregnancy-specific TIR 63-140 mg/dL (ps-TIR) of 66% and maintained the ps-TIR until delivery (median ps-TIR 83%). All patients had slightly better metrics during the night than during the day, with a very low time below range of < 63 mg/dL. Optimal glycaemic values were also maintained on the day of labour and delivery (median ps-TIR 92.5%) and in the first 30 days postpartum, with no severe hypoglycaemia. The only neonatal complications were jaundice in one child and an interatrial defect in another child. Conclusion In our well-selected and trained patients, use of the MiniMed (TM) 780G helped to achieve and maintain ps-metrics from the pregestational period to delivery despite the fact that the algorithm is not set to achieve the ambitious glycaemic values recommended for pregnancy.
引用
收藏
页码:1185 / 1194
页数:10
相关论文
共 50 条
  • [41] Psychosocial Outcomes with the Omnipod® 5 Automated Insulin Delivery System in Children and Adolescents with Type 1 Diabetes and Their Caregivers
    Hood, Korey K.
    Polonsky, William H.
    MacLeish, Sarah A.
    Levy, Carol J.
    Forlenza, Gregory P.
    Criego, Amy B.
    Buckingham, Bruce A.
    Bode, Bruce W.
    Hansen, David W.
    Sherr, Jennifer L.
    Brown, Sue A.
    DeSalvo, Daniel J.
    Mehta, Sanjeev N.
    Laffel, Lori M.
    Bhargava, Anuj
    Huyett, Lauren M.
    Vienneau, Todd E.
    Ly, Trang T.
    PEDIATRIC DIABETES, 2023, 2023
  • [42] Automated feedback-controlled insulin delivery in children with type 1 diabetes mellitus (T1D): A preliminary report
    Weinzimer, Stuart A.
    Steil, Garry M.
    Kurtz, Natalie
    Swan, Karena L.
    Tamborlane, William V.
    DIABETES, 2006, 55 : A102 - A102
  • [43] Exenatide Treatment for 6 Months Improves Insulin Sensitivity in Adults With Type 1 Diabetes. Diabetes Care 2014;37:666-670
    Chaudhuri, Ajay
    Kuhadiya, Nitesh
    Ghanim, Husam
    Dandona, Paresh
    DIABETES CARE, 2014, 37 (10) : E218 - E218
  • [44] Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes
    Bergenstal, Richard M.
    Garg, Satish
    Weinzimer, Stuart A.
    Buckingham, Bruce A.
    Bode, Bruce W.
    Tamborlane, William V.
    Kaufman, Francine R.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (13): : 1407 - 1408
  • [45] Use of automated insulin delivery during major surgery in patients with type 1 diabetes: Two case reports
    Stadnik, Julia
    Seget, Sebastian
    Tarasiewicz, Mateusz
    Jarosz-Chobot, Przemyslawa
    Piatek, Karolina
    Drozdz, Maria
    Czarniecka, Agnieszka
    Koszutski, Tomasz
    Waleza-Widuch, Anna
    Olejnik, Krzysztof
    Nowinski, Bogdan
    JOURNAL OF DIABETES INVESTIGATION, 2024,
  • [46] AUTOMATED INSULIN TREATMENT IN WOMEN WITH TYPE 1 DIABETES: EVIDENCE FROM REAL-WORLD DATA
    Brown, S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A22 - A22
  • [47] Lived experience of older adults with type 1 diabetes using closed-loop automated insulin delivery in a randomised trial
    Kubilay, Erin
    Trawley, Steven
    Ward, Glenn M.
    Fourlanos, Spiros
    Grills, Charlotte A.
    Lee, Melissa H.
    MacIsaac, Richard J.
    O'Neal, David N.
    O'Regan, Niamh A.
    Sundararajan, Vijaya
    Vogrin, Sara
    Colman, Peter G.
    McAuley, Sybil A.
    DIABETIC MEDICINE, 2023, 40 (04)
  • [48] Exenatide Treatment for 6 Months Improves Insulin Sensitivity in Adults With Type 1 Diabetes. Diabetes Care 2014;37:666-670 RESPONSE
    Sarkar, Gayatri
    Alattar, May
    Brown, Rebecca J.
    Quon, Michael J.
    Harlan, David M.
    Rother, Kristina I.
    DIABETES CARE, 2014, 37 (10) : E219 - E220
  • [49] Reinforcement of telemedicine and smartphone inpact of a trining functional education to insulin therapy in patients qith type 1 diabetes. Study TELFIT (NCT00758082)
    Bakouline, M. Chobert
    Debaty, I.
    Halimi, S.
    Quesade, J. L.
    Rueff, A.
    Carpentier, B.
    Gilbert, C.
    Boudrot, E.
    Ressel, M. E.
    Siaud, C.
    Bosson, J. L.
    Benhamou, P. Y.
    DIABETES & METABOLISM, 2011, 37 : A13 - A14
  • [50] Variability of Glycemic Outcomes and Insulin Requirements Throughout the Menstrual Cycle: A Qualitative Study on Women With Type 1 Diabetes Using an Open-Source Automated Insulin Delivery System
    Mewes, Darius
    Waldchen, Mandy
    Knoll, Christine
    Raile, Klemens
    Braune, Katarina
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (05): : 1304 - 1316