Radiofrequency ablation for the treatment of great saphenous venous insufficiency using a newly developed VENISTAR catheter: A preliminary study

被引:0
|
作者
Min, Jeeyoung [1 ]
Hwang, Jin Ho [1 ,3 ]
Park, Sang Woo [1 ]
Hwang, Jae Joon [2 ]
Kim, Jun Seok [2 ]
Lee, Song Am [2 ]
Chee, Hyun Keun [2 ]
机构
[1] Konkuk Univ, Dept Radiol, Sch Med, Seoul, South Korea
[2] Konkuk Univ, Sch Med, Dept Thorac & Cardiovasc Surg, Seoul, South Korea
[3] Konkuk Univ, Dept Radiol, Sch Med, 120 Neungdong Ro, Seoul 05029, South Korea
关键词
Radiofrequency ablation; new catheter; chronic venous insufficiency; great saphenous vein; CLINICAL-PRACTICE-GUIDELINES; VARICOSE-VEINS; VASCULAR-SURGERY; LASER-ABLATION; MULTICENTER; SOCIETY;
D O I
10.1177/17085381241250112
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives This study was aimed to assess the preliminary outcomes of radiofrequency ablation (RFA) using a newly developed catheter (VENISTAR) for the treatment of incompetent great saphenous veins (GSVs). Methods In this prospective observational study, endovenous RFA using a VENISTAR catheter was performed on 16 saphenous veins in 12 patients between August and November 2019. Patients' pre- and post-procedural data were recorded. Doppler ultrasound imaging and clinical evaluation were performed at 1 week and 1, 3, and 6 months to determine the efficacy and safety of the treatment. Results Technical success and complete closure of the targeted GSVs immediately after the procedure were observed in all 16 limbs (100%). However, one patient (one limb) was found to have partial occlusion without significant reflux after 1 week of follow-up. Kaplan-Meier analysis yielded a complete occlusion rate of 93% at 6 months of follow-up. The Venous Clinical Severity Scores at the time of all follow-up were significantly lower than those at baseline (3.3 +/- 1.1 at baseline to 0.6 +/- 0.6, 0.3 +/- 0.6, 0.1 +/- 0.4, and 0.2 +/- 0.4 at 1 week and 1, 3, and 6 months, respectively) (p < .001). Mild post-procedural pain was noted in 7 and 4 limbs at 1 week and 1 month, respectively. Grade 1 ecchymosis over the ablated segment was noted in 5 (35.7%) of 14 limbs at 1-week follow-up. Conclusions Endovenous treatment of GSV insufficiency using a new VENISTAR radiofrequency catheter has been shown to be feasible, effective, and safe throughout the 6-month follow-up.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Preliminary Results of a New Illuminated Radiofrequency Ablation Catheter for the Treatment of Great Saphenous Vein Reflux Disease
    Beyaz, Metin Onur
    Oztas, Didem Melis
    Ulukan, Mustafa Ozer
    Arslan, Hasan Murat
    Unal, Orcun
    Ugurlucan, Murat
    SURGICAL INNOVATION, 2022, 29 (02) : 234 - 240
  • [2] Sonographic Evaluation of Venous Insufficiency and Sonography-Guided Radiofrequency Ablation of the Great Saphenous Vein
    Garrison, Kassandra L.
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2007, 23 (05) : 272 - 279
  • [3] Outcomes of Radiofrequency Ablation Therapy of Great Saphenous Veins Insufficiency
    Atay, Mehmet
    Altun, Senel
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2022, 32 (08): : 1009 - 1013
  • [4] Practical Implications for Great Saphenous Vein Ablation Using a New Radiofrequency Ablation Catheter: A First Experience, Comparative Study
    Stroever, Stephanie
    Morris, Kellie
    Istrefi, Jugerta
    Madkour, George
    Gupta, Megha
    Dietzek, Alan
    JOURNAL OF VASCULAR SURGERY, 2021, 74 (03) : E277 - E278
  • [5] Comparison of Radiofrequency Ablation and Saphenous Vein Stripping for the Treatment of Recurrent Lower Extremity Venous Insufficiency
    Kanber, Eyup Murat
    Cetin, Hakki Kursat
    VASCULAR AND ENDOVASCULAR SURGERY, 2023, 57 (07) : 726 - 731
  • [6] Radiofrequency Catheter Ablation: The Old Good Friend of Great Saphenous Vein
    Bakracheski, Nikola
    Zimbova, Marija
    Mojsovska, Violeta
    Kovacheska-Bashuroska, Elena
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (04) : S34 - S34
  • [7] Comparative outcomes of radiofrequency endoluminal ablation, invagination stripping, and cryostripping in the treatment of great saphenous vein insufficiency
    Stötter, L
    Schaaf, I
    Bockelbrink, A
    PHLEBOLOGY, 2006, 21 (02) : 60 - 64
  • [8] A Comparison of 1470-nm Endovenous Laser Ablation and Radiofrequency Ablation in the Treatment of Great and Small Saphenous Vein Insufficiency
    Torma, Norbert
    Sihotsky, Vladimir
    Kopolovets, Ivan
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (05) : E127 - E128
  • [9] Mechanochemical endovenous ablation for the treatment of great saphenous vein insufficiency
    van Eekeren, Ramon R. J. P.
    Boersma, Doeke
    Holewijn, Suzanne
    Werson, Debora A. B.
    de Vries, Jean Paul P. M.
    Reijnen, Michel M. J. P.
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2014, 2 (03) : 282 - 288
  • [10] The safety of radiofrequency ablation of the great saphenous vein in patients with previous venous thrombosis
    Puggioni, Alessandra
    Marks, Natalie
    Hingorani, Anil
    Shiferson, Alexander
    Alhalbouni, Saadi
    Ascher, Enrico
    JOURNAL OF VASCULAR SURGERY, 2009, 49 (05) : 1248 - 1255