Significance of Dynamic Axial Stretching on Estimating Biomechanical Behavior and Properties of the Human Ascending Aorta

被引:1
|
作者
Parikh, Shaiv [1 ]
Giudici, Alessandro [1 ,2 ]
Huberts, Wouter [1 ,3 ]
Delhaas, Tammo [1 ]
Bidar, Elham [4 ]
Spronck, Bart [1 ,5 ]
Reesink, Koen [1 ]
机构
[1] Maastricht Univ, CARIM Sch Cardiovasc Dis, Dept Biomed Engn, Maastricht, Netherlands
[2] Maastricht Univ, GROW Sch Oncol & Reprod, Maastricht, Netherlands
[3] Eindhoven Univ Technol, Dept Biomed Engn, Cardiovasc Biomech, Eindhoven, Netherlands
[4] Maastricht Univ, Heart & Vasc Ctr, Dept Cardiothorac Surg, Med Ctr, Maastricht, Netherlands
[5] Macquarie Univ, Fac Med Hlth & Human Sci, Macquarie Med Sch, Sydney, Australia
关键词
Ascending thoracic aorta; Biaxial stretching; Biomechanical response; Parameter estimation; ARTERIAL-WALL MECHANICS;
D O I
10.1007/s10439-024-03537-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Contrary to most vessels, the ascending thoracic aorta (ATA) not only distends but also elongates in the axial direction. The purpose of this study is to investigate the biomechanical behavior of the ascending thoracic aorta (ATA) in response to dynamic axial stretching during the cardiac cycle. In addition, the implications of neglecting this dynamic axial stretching when estimating the constitutive model parameters of the ATA are investigated. The investigations were performed through in silico simulations by assuming a Gasser-Ogden-Holzapfel (GOH) constitutive model representative of ATA tissue material. The GOH model parameters were obtained from biaxial tests performed on four human ATA tissues in a previous study. Pressure-diameter curves were simulated as synthetic data to assess the effect of neglecting dynamic axial stretching on estimating constitutive model parameters. Our findings reveal a significant increase in axial stress (similar to 16%) and stored strain energy (similar to 18%) in the vessel when dynamic axial stretching is considered, as opposed to assuming a fixed axial stretch. All but one artery showed increased volume compliance while considering a dynamic axial stretching condition. Furthermore, we observe a notable difference in the estimated constitutive model parameters when dynamic axial stretching of the ATA is neglected, compared to the ground truth model parameters. These results underscore the critical importance of accounting for axial deformations when conducting in vivo biomechanical characterization of the ascending thoracic aorta.
引用
收藏
页码:2485 / 2495
页数:11
相关论文
共 50 条
  • [31] Layer-specific biomechanical and histological properties of normal and dissected human ascending aortas
    Guo, Xiaoya
    Yu, Han
    Wang, Liang
    Zhai, Yali
    Li, Jiantao
    Tang, Dalin
    Sun, Haoliang
    HELIYON, 2024, 10 (14)
  • [32] Biomechanical properties of the Marfan's aortic root and ascending aorta before and after personalised external aortic root support surgery
    Singh, S. D.
    Xu, X. Y.
    Pepper, J. R.
    Treasure, T.
    Mohiaddin, R. H.
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (08) : 759 - 766
  • [33] Effects of an acute bout of dynamic stretching on biomechanical properties of the gastrocnemius muscle determined by shear wave elastography
    Pamboris, George M.
    Noorkoiv, Marika
    Baltzopoulos, Vasilios
    Gokalp, Hulya
    Marzilger, Robert
    Mohagheghi, Amir A.
    PLOS ONE, 2018, 13 (05):
  • [34] Biomechanical properties of human umbilical vessels at different gestational ages and their clinical significance
    Li, W.
    Huang, T.
    Zeng, F.
    Zhou, L.
    2001, West China University of Medical Sciences (18):
  • [35] Experimental/numerical study to assess mechanical properties of healthy and Marfan syndrome ascending thoracic aorta under axial and circumferential loading
    Jarrahi, A.
    Karimi, A.
    Navidbakhsh, M.
    Ahmadi, H.
    MATERIALS TECHNOLOGY, 2016, 31 (05) : 247 - 254
  • [36] Dynamic and static properties of the human knee joint in axial rotation
    Zhang, LQ
    Zeng, KF
    Wang, GZ
    Nuber, G
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 1738 - 1741
  • [37] Effect of axial prestretch and adipose tissue on the inflation-extension behavior of the human abdominal aorta
    Vonavkova, Tereza
    Horny, Lukas
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (03) : 81 - 91
  • [38] Local Material Properties of Human Aorta under Dynamic Biaxial Loading
    Kermani, G.
    Darvish, K.
    2012 38TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2012, : 199 - 200
  • [39] Biomechanical behavior of muscle-tendon complex during dynamic human movements
    Fukashiro, Senshi
    Hay, Dean C.
    Nagano, Akinori
    Journal of Applied Biomechanics, 2006, 22 (02): : 131 - 147
  • [40] Biomechanical behavior of muscle-tendon complex during dynamic human movements
    Fukashiro, Senshi
    Hay, Dean C.
    Nagano, Akinori
    JOURNAL OF APPLIED BIOMECHANICS, 2006, 22 (02) : 131 - 147