Natural convection and field synergy principle analysis of the influence of fins redistribution on the performance of a latent heat storage unit in a successive charge and discharge

被引:3
|
作者
Kabore, Appolinaire [1 ,2 ]
Tala, Jules Voguelin Simo [1 ]
Younsi, Zohir [3 ]
Bougeard, Daniel [1 ]
机构
[1] Univ Lille, Inst Mines Telecom, Ctr Energy & Environm, IMT Nord Europe, F-59000 Lille, France
[2] French Environm & Energy Management Agcy, 20,Ave Gresille,BP 90406, F-49004 Angers 01, France
[3] Univ Lille, Univ Artois, Lab Genie Civil & GeoEnvironm, Inst Mines Telecom,Junia,ULR 4515 LGCgE, F-59000 Lille, France
关键词
Heat transfer enhancement; Renewable energy; LHTES; Fins redistribution; Melting/solidification; Successive charging -discharging; Energy efficiency;
D O I
10.1016/j.est.2024.111855
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The present study focuses on analyzing the impact of enhancing the heat exchanges on the shell side by surface extension on the kinetics of melting/solidification in a latent heat thermal energy storage (LHTES) unit. Particular attention is paid to the influence of fins redistribution on the performance of the LHTES unit, natural convection, and Phase Change Material (PCM) melting/solidification kinetics. The particularity of this study lies in the improvement of the LHTES unit performances in a successive charging-discharging operation by only redistributing the fins while keeping the same total heat transfer surface, PCM volume, and compactness. The first part of the study consists of evaluating the impact of fin redistribution for the same total heat transfer surface on the LHTES unit performance. Attention was paid to the fully charging and discharging times and the heat duty absorbed or released during the melting or solidification process. For this purpose, 4 configurations of LHTES units having 4 and 8 radial fins with the same total transfer surface were analyzed, with the aim of ensuring a maximum performance on charging process. In a second part, an improved configuration was proposed in order to minimize the successive charging and discharging time for a cyclic operation of the LHTES unit. The coordination factor derived from the field synergy principle, PCM liquid fraction, the heat duty exchanged, phase change kinetics, and liquid PCM velocity were used as performance key factors. They were used to analyze and compare the different configurations in order to find the best configuration for a successive charging-discharging operation. The selected improved configuration has been found to enhance both the charging and discharging processes. It leads to the reduction of the successive charging-discharging overall duration by 10 % to 47 % compared to the other configurations investigated with the same heat transfer surface. The enhanced LHTES unit developed in the present study is intended to improve the thermal comfort of buildings by valorizing and storing renewable and waste energies.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Thermal performance enhancement of shell and tube Latent Heat Storage Unit using longitudinal fins
    Rathod, Manish K.
    Banerjee, Jyotirmay
    APPLIED THERMAL ENGINEERING, 2015, 75 : 1084 - 1092
  • [22] Charging performance optimization of a latent heat storage unit with fractal tree-like fins
    Yu, Cheng
    Wu, Suchen
    Huang, Yongping
    Yao, Feng
    Liu, Xiangdong
    JOURNAL OF ENERGY STORAGE, 2020, 30
  • [23] Effect of ribbed rotation on heat storage performance of phase change thermal storage unit and field synergy analysis
    Tian Y.
    Zhao M.
    Hu M.
    Zhang F.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (03): : 395 - 400
  • [24] Discharge performance assessment of a vertical double-pipe latent heat storage unit equipped with circular Y-shaped fins
    Ben Khedher, Nidhal
    Togun, Hussein
    Abed, Azher M.
    Al-Najjar, Hussein M. Taqi
    Dulaimi, Anmar
    Mohammed, Hayder I.
    Mahdi, Jasim M.
    Yvaz, A.
    Talebizadehsardari, Pouyan
    JOURNAL OF BUILDING ENGINEERING, 2023, 75
  • [25] Performance analysis of natural convection biomass operated grain dryer coupled with latent heat storage medium
    Kumar, Dhananjay
    Mahanta, Pinakeswar
    Kalita, Pankaj
    MATERIALS TODAY-PROCEEDINGS, 2022, 58 : 902 - 905
  • [26] The negative effect of natural convection in a vertical shell and tube latent heat energy storage unit
    Wang, Leli
    Wang, Liangbi
    Wang, Ye
    APPLIED THERMAL ENGINEERING, 2024, 244
  • [27] A novel compensating fins configuration for improving the thermal performance of latent heat thermal energy storage unit
    Wu, Junting
    Chen, Qicheng
    Zhang, Yingjin
    Sun, Kanglong
    JOURNAL OF ENERGY STORAGE, 2021, 44
  • [28] Numerical study on the effect of umbrella-shaped fins in charging performance of a latent heat storage unit
    Yu, Detao
    Qiu, Yan
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (15) : 22991 - 23003
  • [29] Analysis of the heat storage performance of the latent heat storage unit combined with frustum wavy tube
    Ding L.
    Xu H.
    Zhang C.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2024, 43 (03): : 1214 - 1223
  • [30] Effects of natural convection on latent heat storage performance of salt in a horizontal concentric tube
    Tao, Y. B.
    He, Y. L.
    APPLIED ENERGY, 2015, 143 : 38 - 46