Biomechanical analysis of load distribution in porcine hip joints at different acetabular coverages

被引:0
|
作者
Tachibana, Tetsuya [1 ,2 ]
Katagiri, Hiroki [1 ,2 ]
Matsuda, Junpei [3 ]
Ozeki, Nobutake [3 ]
Watanabe, Toshifumi [1 ]
Sekiya, Ichiro [3 ]
Jinno, Tetsuya [1 ]
机构
[1] Dokkyo Med Univ, Saitama Med Ctr, Dept Orthoped Surg, 2-1-50 Minami Koshigaya, Koshigaya, Saitama 3438555, Japan
[2] Tokyo Med & Dent Univ TMDU, Grad Sch Med & Dent Sci, Dept Joint Surg & Sports Med, Tokyo, Japan
[3] Tokyo Med & Dent Univ, Ctr Stem Cell & Regenerat Med, Tokyo, Japan
关键词
Biomechanics; Osteotomy; Hip dysplasia; Porcine; Femoroacetabular impingement; CONTACT MECHANICS; DYSPLASIA; STRESS; VALIDATION;
D O I
10.1186/s12891-024-07701-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundDevelopmental dysplasia of the hip causes secondary osteoarthritis. Finite element analysis suggests high hip joint contact pressure in patients with hip dysplasia and a reduction in contact pressure after periacetabular osteotomy. However, few biomechanical studies have examined the load distribution in the hip joint. This study aimed to investigate the biomechanical properties of load distribution in porcine hip joints at different acetabular coverages.MethodsSix porcine hip joints were analyzed using three models: 1) neutral coverage, 2) 15 degrees under-coverage (defined as dysplasia model), and 3) 15 degrees over-coverage created by varying the acetabular coverage. The load distribution was assessed using a pressure-mapping sensor system after applying a loading force of 100 N to the hip joint.ResultsIn the dysplasia model, the load was concentrated at the acetabular rim; in the neutral and over-coverage models, it was dispersed. The average contact pressure was significantly higher in the dysplasia model than in the neutral coverage model ([0.42 vs. 0.3 MPa]; p = 0.004). The contact area was significantly smaller in the dysplasia model than in the neutral coverage model ([250.7 vs. 345.0 mm2]; p = 0.004). No significant differences were observed in contact pressure or area between the neutral and over-coverage models.ConclusionsInsufficient acetabular coverage in the dysplasia model demonstrated higher contact pressure and smaller contact area than the neutral model. Conversely, the contact pressure and area in the over-coverage model did not differ significantly from those in the normal model. Therefore, surgeons should note that acetabular coverage overcorrection has limited effect; normalization is crucial during periacetabular osteotomy.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Achieving uniform thread load distribution in bolted joints using different pitch values
    Coria, Ibai
    Abasolo, Mikel
    Gutierrez, Aitor
    Aguirrebeitia, Josu
    [J]. MECHANICS & INDUSTRY, 2020, 21 (06)
  • [22] Analysis of Biomechanical Response After Corneal Crosslinking with Different Fluence Levels in Porcine Corneas
    Fischinger, Isaak
    Reifeltshammer, Sophia A.
    Seiler, Theo G.
    Nambiar, Malavika H.
    Komninou, Maria A.
    Buchler, Philippe
    Wendelstein, Jascha
    Langenbucher, Achim
    Bolz, Matthias
    [J]. CURRENT EYE RESEARCH, 2023, 48 (08) : 719 - 723
  • [23] Biomechanical analysis of the placement of fixation lag screw in different intertrochanteric hip fracture angles
    Choh, Alex C.T.
    Chong, Desmond Y.R.
    [J]. Biosurface and Biotribology, 2019, 5 (02): : 52 - 56
  • [24] FE Modeling for Load Distribution Analysis of Multi-bolt Composite Joints
    Xu, Zhi-xiang
    [J]. Design, Manufacturing and Mechatronics, 2014, 551 : 104 - 107
  • [25] FINITE-ELEMENT ANALYSIS FOR LOAD DISTRIBUTION OF MULTI-FASTENER JOINTS
    WANG, SM
    HAN, YX
    [J]. JOURNAL OF COMPOSITE MATERIALS, 1988, 22 (02) : 124 - 135
  • [26] Biomechanical analysis of transverse acetabular fracture fixation in the elderly via the posterior versus the anterior approach with and without a total hip arthroplasty
    Moktar, Joel
    Machin, Alan
    Bougherara, Habiba
    Schemitsch, Emil H.
    Zdero, Radovan
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (09) : 966 - 974
  • [27] STRESS-ANALYSIS OF REINFORCED TUBULAR JOINTS SUBJECTED TO DIFFERENT LOAD TYPES
    SOH, AK
    SOH, CK
    HOON, KH
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1994, 104 (03) : 257 - 266
  • [28] Changes of Load Distribution on Cup-Bone Interface at the Different Positions of Non-Cemented Acetabular Cup
    Li, Dongsong
    Li, Shuqiang
    Cai, Bo
    Feng, Wei
    Liu, Jianguo
    [J]. MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES (ICMEAT 2013), 2014, 510 : 297 - +
  • [29] Influence of Different Boundary Conditions in Finite Element Analysis on Pelvic Biomechanical Load Transmission
    Hu, Pan
    Wu, Tao
    Wang, Hui-zhi
    Qi, Xin-zheng
    Yao, Jie
    Cheng, Xiao-dong
    Chen, Wei
    Zhang, Ying-ze
    [J]. ORTHOPAEDIC SURGERY, 2017, 9 (01) : 115 - 122
  • [30] Viral load and histological distribution of atypical porcine pestivirus in different tissues of naturally infected piglets
    Jianxin Liu
    Zhenbiao Li
    Xujiao Ren
    Huizi Li
    Rong Lu
    Yuan Zhang
    Zhangyong Ning
    [J]. Archives of Virology, 2019, 164 : 2519 - 2523