A direct enzyme biosensor for rapid determination of ethanol in plasma

被引:0
|
作者
Liang, Xiaohui [1 ]
Wang, Binglian [2 ]
Ma, Yaohong [2 ]
Gong, Weili [2 ]
Liu, Qingai [2 ]
Zheng, Lan [2 ]
Yang, Yan [2 ]
Meng, Qingjun [2 ]
Si, Hongyu [1 ]
机构
[1] Energy Institute, Qilu University of Technology ( Shandong Academy of Sciences), Jinan,250014, China
[2] Biology Institute, Qilu University of Technology(Shandong Academy of Sciences), Shandong Provincial Key Laboratory of Biosensors, Jinan,250103, China
关键词
Electrodes - Enzyme activity - Enzyme electrodes - Gas chromatography - Graphene - Probes;
D O I
10.13595/j.cnki.issn1000-0720.2021.012104
中图分类号
学科分类号
摘要
A columnar electrode probe was prepared using platinum Pt and silver Ag as the positive and negative pole. The surface of the probe was coated by graphene oxide nanoparticles to construct a novel nano modified columnar electrode. Ethanol oxidase was directly immobilized on the electrode probe to make ethanol direct biosensor for the determination. The results showed that the detection time was 12 s. The direct test conditions including pH 2-11 and a temperature of 15℃-40℃ . The linear range was 0. 01-2 mg / mL and the limit of detection was 10 μg / mL. The enzyme biosensor showed a good stability with the relative standard deviation RSD of 0. 7% . After the first calibration the enzyme electrode activity remained stable within 33 days with the RSD of 1. 1% . The recoveries were 99. 3%-101% . There was no significant difference between the detection results obtained from this method and the gas chromatography. The new method was expected to be used for the online determination based on the benifits like real time rapid and accurate. © 2021, Youke Publishing Co.,Ltd. All rights reserved.
引用
收藏
页码:1021 / 1025
相关论文
共 50 条
  • [21] Development of sensitive direct chemiluminescent enzyme immunoassay for the determination of dihydroartemisinin in plasma
    Zehnacker, Laura
    Nevers, Marie-Claire
    Sinou, Veronique
    Parzy, Dominique
    Creminon, Christophe
    Parzy, Daniel
    Azoulay, Stephane
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (25) : 7823 - 7830
  • [22] Enzyme Based Amperometric Biosensor for Adenine Determination
    Boka, Beata
    Adanyi, Nora
    Virag, Diana
    Frebort, Ivo
    Kiss, Attila
    [J]. ELECTROANALYSIS, 2013, 25 (01) : 237 - 242
  • [23] A Rapid Sensitive Biosensor System for Rapid Determination of Flourescence Steroid
    Yu Yuan-Hua
    Wang Jing-Hua
    Song Yu
    Yang Jia-Xin
    Zhang Hao
    Liu Hong
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (07) : 1048 - 1051
  • [24] Aptamer Biosensor for Selective and Rapid Determination of Insulin
    Taghdisi, Seyed Mohammad
    Danesh, Noor Mohammad
    Lavaee, Parirokh
    Emrani, Ahmad Sarreshtehdar
    Ramezani, Mohammad
    Abnous, Khalil
    [J]. ANALYTICAL LETTERS, 2015, 48 (04) : 672 - 681
  • [25] Novel DNA Biosensor for Direct Determination of Carrageenan
    Riyadh Abdulmalek Hassan
    Lee Yook Heng
    Ling Ling Tan
    [J]. Scientific Reports, 9
  • [26] Novel DNA Biosensor for Direct Determination of Carrageenan
    Hassan, Riyadh Abdulmalek
    Heng, Lee Yook
    Tan, Ling Ling
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [27] Biosensor for direct determination of organophosphorus pesticides.
    Lei, Y
    Mulchandani, P
    Chen, W
    Wang, J
    Mulchandani, A
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U129 - U129
  • [28] A RAPID COLORIMETRIC DETERMINATION OF ETHANOL IN BLOOD
    BROWER, ME
    WOODBRID.JE
    [J]. CLINICAL CHEMISTRY, 1970, 16 (06) : 539 - &
  • [29] A RAPID ULTRAMICRO METHOD FOR DIRECT DETERMINATION OF TOTAL PLASMA CHOLESTEROL IN SMALL ANIMALS
    POOLE, NF
    [J]. LABORATORY ANIMAL CARE, 1965, 15 (06): : 426 - +
  • [30] Determination of the biomolecular composition of an enzyme-polymer biosensor
    Griffith, A
    Glidle, A
    Beamson, G
    Cooper, JM
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1997, 101 (11): : 2092 - 2100