Theory of nonuniformity related to spectrum response in IR imaging system

被引:0
|
作者
Yu, Haitao [1 ]
Ma, Jinpeng [2 ]
Fan, Yun [2 ]
Li, Ke [2 ]
Zhang, Chunxi [1 ]
机构
[1] School of Instrument Science and Optoelectronic Engineering, Beihang University, Beijing,100191, China
[2] Tianjin Jinhang Technical Physics Institute, Tianjin,300300, China
关键词
Thermography (imaging) - Imaging systems;
D O I
10.3788/IRLA201948.0204002
中图分类号
学科分类号
摘要
Non -uniformity correction based on blackbody calibration is widely used in staring infrared imaging system. But in some cases, blackbody calibration method is not applicable. Two kinds of cases were presented: when the IR imaging system facing to the sky background, or observing normal objects through high temperature optical window in high speed aircraft. Based on the analysis of the response characteristics of infrared imaging system, the concept of non -uniformity with response spectral was proposed. It was pointed out that the correction results of blackbody calibration method depended on the spectral distribution of scene. The principle of non -uniformity with response spectrum was analyzed, which included internal and external reasons. The intrinsic factor was that the quantum efficiency of different pixels of infrared detector varies with spectrum, and the external factor was that the radiation spectrum distribution of application scene was quite different from blackbody. Suggestions were given to solve response spectral non-uniformity. © 2019, Editorial Board of Journal of Infrared and Laser Engineering. All right reserved.
引用
收藏
相关论文
共 50 条
  • [41] The Pancreatic Ductal System: Spectrum of Imaging Findings
    George, V
    Surabhi, V
    Tammisetti, V
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [42] Histiocytosis: Imaging Spectrum in the Central Nervous System
    Midia, M.
    Kirby, J.
    Miabi, Z.
    Chhibber, S.
    Jeddyian, S.
    Miller, E.
    Haider, E.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [43] Imaging spectrum of amyloid-related imaging abnormalities associated with aducanumab immunotherapy
    Sotoudeh, Houman
    Alizadeh, Mohammadreza
    Shahidi, Ramin
    Shobeiri, Parnian
    Saadatpour, Zahra
    Wheeler, C. Austin
    Natelson Love, Marissa
    Tanwar, Manoj
    [J]. FRONTIERS IN RADIOLOGY, 2024, 3
  • [44] IR Expert: A New Type of IR Spectroscopy Information System for Solving Spectrum-Structure Problems
    V. N. Piottukh-Peletskii
    K. S. Chmutina
    M. V. Korolevich
    [J]. Journal of Structural Chemistry, 2003, 44 : 763 - 770
  • [45] IR EXPERT: A new type of IR spectroscopy information system for solving spectrum-structure problems
    Piottukh-Peletskii, VN
    Chmutina, KS
    Korolevich, MV
    [J]. JOURNAL OF STRUCTURAL CHEMISTRY, 2003, 44 (05) : 763 - 770
  • [46] Frequency response analysis of IPMC actuators by an IR system
    Bonomo, C
    Fortuna, L
    Giannone, P
    Graziani, S
    [J]. Smart Structures and Materials 2005: Electroactive Polymer Actuators and Devices( EAPAD), 2005, 5759 : 41 - 48
  • [47] Spectrum management issues related to the AEHF system
    Einhorn, Arthur
    Miller, Jim
    [J]. 2007 IEEE MILITARY COMMUNICATIONS CONFERENCE, VOLS 1-8, 2007, : 3119 - +
  • [48] STATIC PERFORMANCE PREDICTION AIRBORNE MODEL FOR AN IMAGING IR SYSTEM
    MILLER, PC
    [J]. IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1975, 11 (04) : 681 - 682
  • [49] Effect of pneumatic calefaction of the dome on IR imaging system quality
    [J]. Guan, Y. (guanyz@hit.edu.cn), 1600, Chinese Society of Astronautics (42):
  • [50] How might spatial nonuniformity of dose in a homogeneous biological system affect its total response?
    Pickard, WF
    [J]. BIOELECTROMAGNETICS, 2001, 22 (01) : 66 - 70