Experimental investigation on the influence of ejector geometry on the pull-down performance of an ejector-enhanced auto-cascade low-temperature freezer

被引:17
|
作者
Bai, Tao [1 ]
Xie, Hongxu [1 ]
Liu, Shuilong [1 ]
Yan, Gang [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Experimental investigation; Auto-cascade refrigeration cycle; Ejector geometry; Low-temperature freezer; Pull-down performance; REFRIGERATION SYSTEM; 2-PHASE EJECTOR; MIXTURE; EXERGY; ENERGY; CYCLE;
D O I
10.1016/j.ijrefrig.2021.08.021
中图分类号
O414.1 [热力学];
学科分类号
摘要
Employing an ejector to recover the expansion work of the auto-cascade refrigeration cycle is a feasible method to improve the system performance. The system operation characteristics are closely relevant to the ejector geometry parameters. In order to obtain the critical structure parameters influencing the freezer's pull-down performance, experimental research was conducted on an ejector-enhanced auto-cascade refrigeration cycle applied in a low-temperature freezer. The impacts of the ejector nozzle throat, mixing chamber diameter and length, and the nozzle exit position on the system's pull-down and steady operation characteristics were explored. The experimental results illustrated that the cooling rate and the attainable freezing temperature were mainly influenced by the nozzle throat and mixing chamber length instead of the nozzle exit position and mixing chamber diameter. The nozzle throat diameter of 0.52 mm and the mixing chamber length of 25 mm was optimal concerning the fastest cool-down rate and lowest freezing temperature of -61.2 degrees C. At the early phase of the pulldown process, a small mixing chamber diameter would cause the ejector malfunction of the pressure lift. There was a worst nozzle exit position of slowing down the pull-down speed, rising the freezing temperature, and reducing the system COP and exergy efficiency at the given operations. The ejector yielded the maximum pressure lift ratio of 1.196 and the entrainment ratio of 0.523 at the optimal ejector geometries. This work would be helpful to guide the ejector structure optimization for the ejector-enhanced auto-cascade low-temperature freezers.
引用
收藏
页码:41 / 50
页数:10
相关论文
共 28 条
  • [21] Thermodynamic analysis of auto-cascade refrigeration cycles, with and without ejector, for ultra low temperature freezing using a mixture of refrigerants R600a and R1150
    Angel Rodriguez-Jara, Enrique
    Jose Sanchez-de-la-Flor, Francisco
    Antonio Exposito-Carrillo, Jose
    Manuel Salmeron-Lissen, Jose
    APPLIED THERMAL ENGINEERING, 2022, 200
  • [22] Performance evaluation of an ejector subcooling refrigeration cycle with zeotropic mixture R290/R170 for low-temperature freezer applications
    Liu, Ye
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2019, 161
  • [23] Experimental and numerical investigation of the influence of the two-phase ejector geometry on the performance of the R744 heat pump
    Banasiak, Krzysztof
    Hafner, Armin
    Andresen, Trond
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (06): : 1617 - 1625
  • [24] Performance evaluation of NH3/CO2 cascade refrigeration system with ejector subcooling for low-temperature cycle
    Chi, Weikai
    Yang, Qichao
    Chen, Xiaonan
    Liu, Guangbin
    Zhao, Yuanyang
    Li, Liansheng
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 136 : 162 - 171
  • [25] Experimental investigation on the performance of a-120 °C ultralow temperature refrigeration system based on a three-stage auto-cascade cycle
    Qin, Yanbin
    Zhang, Shaojie
    Zhang, Hua
    Tan, Yuxuan
    Zhou, Guozhong
    Liu, Baolin
    ENERGY, 2025, 320
  • [26] Thermodynamic performance of the fractionated auto-cascade refrigeration cycle coupled with two-phase ejector using R1150/R600a at-80 °C temperature level
    Tan, Yingying
    Li, Xiuzhen
    Wang, Lin
    Huang, Lisheng
    Xiao, Yi
    Wang, Zhanwei
    Li, Shaoqiang
    ENERGY, 2023, 281
  • [27] Experimental Investigation of the Steam Ejector in a Single-Effect Thermal Vapor Compression Desalination System Driven by a Low-Temperature Heat Source
    Dong, Jingming
    Wang, Weining
    Han, Zhitao
    Ma, Hongbin
    Deng, Yangbo
    Su, Fengmin
    Pan, Xinxiang
    ENERGIES, 2018, 11 (09)
  • [28] Experimental and theoretical investigation on the energetic and economic performance of low-temperature cascade air-source heat pump considering the effects of cascade heat exchanger
    Xu, Yingjie
    Zhang, Jiahe
    Shen, Xi
    Han, Xiaohong
    Chen, Hongyu
    Xu, Xiaoxiao
    APPLIED THERMAL ENGINEERING, 2024, 236