Experimental investigation on the influence of ejector geometry on the pull-down performance of an ejector-enhanced auto-cascade low-temperature freezer

被引:17
|
作者
Bai, Tao [1 ]
Xie, Hongxu [1 ]
Liu, Shuilong [1 ]
Yan, Gang [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Experimental investigation; Auto-cascade refrigeration cycle; Ejector geometry; Low-temperature freezer; Pull-down performance; REFRIGERATION SYSTEM; 2-PHASE EJECTOR; MIXTURE; EXERGY; ENERGY; CYCLE;
D O I
10.1016/j.ijrefrig.2021.08.021
中图分类号
O414.1 [热力学];
学科分类号
摘要
Employing an ejector to recover the expansion work of the auto-cascade refrigeration cycle is a feasible method to improve the system performance. The system operation characteristics are closely relevant to the ejector geometry parameters. In order to obtain the critical structure parameters influencing the freezer's pull-down performance, experimental research was conducted on an ejector-enhanced auto-cascade refrigeration cycle applied in a low-temperature freezer. The impacts of the ejector nozzle throat, mixing chamber diameter and length, and the nozzle exit position on the system's pull-down and steady operation characteristics were explored. The experimental results illustrated that the cooling rate and the attainable freezing temperature were mainly influenced by the nozzle throat and mixing chamber length instead of the nozzle exit position and mixing chamber diameter. The nozzle throat diameter of 0.52 mm and the mixing chamber length of 25 mm was optimal concerning the fastest cool-down rate and lowest freezing temperature of -61.2 degrees C. At the early phase of the pulldown process, a small mixing chamber diameter would cause the ejector malfunction of the pressure lift. There was a worst nozzle exit position of slowing down the pull-down speed, rising the freezing temperature, and reducing the system COP and exergy efficiency at the given operations. The ejector yielded the maximum pressure lift ratio of 1.196 and the entrainment ratio of 0.523 at the optimal ejector geometries. This work would be helpful to guide the ejector structure optimization for the ejector-enhanced auto-cascade low-temperature freezers.
引用
收藏
页码:41 / 50
页数:10
相关论文
共 28 条
  • [1] Experimental research on the pull-down performance of an ejector enhanced auto-cascade refrigeration system for low-temperature freezer
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    ENERGY, 2018, 157 : 647 - 657
  • [2] Influence of internal heat exchanger position on the performance of ejector-enhanced auto-cascade refrigeration cycle for the low-temperature freezer
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    ENERGY, 2022, 238
  • [3] Experimental investigation of an ejector-enhanced auto-cascade refrigeration system
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2018, 129 : 792 - 801
  • [4] Performance analysis of a modified ejector-enhanced auto-cascade refrigeration cycle
    Liu, Shuilong
    Bai, Tao
    Wei, Yuan
    Yu, Jianlin
    ENERGY, 2023, 265
  • [5] Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer
    Tao Bai
    Yu Lu
    Gang Yan
    Jianlin Yu
    Journal of Thermal Science, 2021, 30 : 2015 - 2026
  • [6] Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer
    Bai, Tao
    Lu, Yu
    Yan, Gang
    Yu, Jianlin
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (06) : 2015 - 2026
  • [7] Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer
    BAI Tao
    LU Yu
    YAN Gang
    YU Jianlin
    JournalofThermalScience, 2021, 30 (06) : 2015 - 2026
  • [8] Thermodynamic analysis of a novel ejector-enhanced auto-cascade refrigeration cycle
    Liu, Jiarui
    Liu, Ye
    Yu, Jianlin
    Yan, Gang
    APPLIED THERMAL ENGINEERING, 2022, 200
  • [9] Experimental investigation on the concentration distribution behaviors of mixture in an ejector enhanced auto-cascade refrigeration system
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 99 : 145 - 152
  • [10] Experimental investigation on the dynamic malfunction behavior of the two-phase ejector in a modified auto-cascade freezer refrigeration system
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    ENERGY CONVERSION AND MANAGEMENT, 2019, 183 : 382 - 390