Thermodynamic analysis of a cascade vapour compression refrigeration system integrated Linde-Hampson cycle

被引:0
|
作者
Kizilcaoglu, Selcuk [1 ]
Kilicarslan, Ali [1 ]
Kurtbas, Irfan [1 ]
机构
[1] Hitit Univ, Fac Engn, Dept Mech Engn, Corum, Turkiye
关键词
vapour compression system; cascade refrigeration; refrigerants; Linde-Hampson; COP; exergy efficiency; exergy destruction;
D O I
10.1504/IJEX.2024.138106
中图分类号
O414.1 [热力学];
学科分类号
摘要
The four-stage cascade vapour compression refrigeration system (CVCRS) integrated Linde-Hampson cycle (CVCRS-LH) is proposed in order to liquefy methane gas. The effects of isentropic efficiency of compressors, methane mass flow rate, evaporating and condensing temperatures on the performance of the four-stage CVCRS-LH and exergy efficiency are investigated with respect to the refrigerants R290, R600a and R161used in the fourth stage. The highest COP and exergy efficiency values were obtained by using R600a as refrigerant for all values of isentropic efficiency of compressors, methane mass flow rate, evaporating and condensing temperatures under the study in the fourth stage of the four stage CVCRS-LH.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Experimental characterization of an innovative refrigeration system coupled with Linde-Hampson cycle and auto-cascade cycle for multi-stage refrigeration temperature applications
    Qin, Yanbin
    Li, Nanxi
    Zhang, Hua
    Jin, Binhui
    Liu, Baolin
    [J]. ENERGY, 2022, 240
  • [2] A thermodynamic analysis of the Linde-Hampson cycle using low-GWP R1234yf-blends
    Qin, Yanbin
    Li, Nanxi
    Zhang, Hua
    Liu, Baolin
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2023, 49
  • [3] Thermodynamic performance analysis of the double effect absorption-vapour compression cascade refrigeration cycle
    Cimsit, Canan
    [J]. JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2018, 13 (01):
  • [4] Thermodynamic and Sustainability Analysis of Vapour Compression Refrigeration System
    Chopra, Kapil
    Sahni, V.
    Mishra, R. S.
    [J]. MATERIALS FOCUS, 2015, 4 (05) : 392 - 396
  • [5] Exergy Analysis of Adiabatic Liquid Air Energy Storage (A-LAES) System Based on Linde-Hampson Cycle
    Szablowski, Lukasz
    Krawczyk, Piotr
    Wolowicz, Marcin
    [J]. ENERGIES, 2021, 14 (04)
  • [6] Thermodynamic performance of a modified-150 °C refrigeration system coupled with Linde-Hampson and three-stage auto-cascade using low-GWP refrigerants
    Qin, Yanbin
    Li, Nanxi
    Zhang, Hua
    Liu, Baolin
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 236 (236)
  • [7] Thermodynamic analysis of an ejector–vapour compressor cascade refrigeration system
    Trung Kien Nguyen
    Chi Hiep Le
    [J]. Journal of Thermal Analysis and Calorimetry, 2020, 141 : 2189 - 2200
  • [8] ENERGY AND EXERGY ANALYSIS OF AN ORGANIC RANKINE CYCLE INTEGRATED WITH VAPOUR COMPRESSION REFRIGERATION SYSTEM
    Malwe, Prateek D.
    Gawali, Bajirao S.
    Choudhari, Mahmadrafik S.
    Dhalait, Rustam S.
    Deshmukh, Nandkishor S.
    [J]. ADVANCES AND APPLICATIONS IN MATHEMATICAL SCIENCES, 2021, 20 (10): : 2137 - 2150
  • [9] Thermodynamic analysis of an ejector-vapour compressor cascade refrigeration system
    Trung Kien Nguyen
    Chi Hiep Le
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 141 (06) : 2189 - 2200
  • [10] Refrigeration Linde-Hampson Machine at 90K Operation by Use of Ozone Friendly Refrigerants
    Dalakov, Petar
    Klier, Juergen
    Rozhentsev, Andrey
    [J]. 15TH CRYOGENICS 2019 IIR INTERNATIONAL CONFERENCE, 2019, : 45 - 52