Beam-hardening correction method for quantifying moisture content in cement paste based on X-ray radiography

被引:0
|
作者
Wang, Xu [1 ]
Dong, Biqin [1 ]
Feng, Xing [1 ]
Hong, Shuxian [1 ]
Huang, Xiaoming [1 ]
机构
[1] Guangdong Provincial Key Laboratory of Durability for Marine Civil Engineering, Shenzhen University, Shenzhen,518060, China
关键词
The X-ray spectrum changes while traveling through specimen; and this phenomenon; known as the beam-hardening effect; breaks the linear relationship between the intensity variety on radiographs and material thickness. In the detection of water transport in cement-based materials; this effect leads to inaccurate results of the quantitative moisture distribution inside the sample; and it is difficult to eliminate this effect by gravimetric calibration. To solve this problem; this paper proposed a calibration strategy for the attenuation coefficient curve of cement-water two-phase specimens; and provided a heuristic mathematical model for fitting the 2D attenuation coefficient surface of cement paste specimens. The experiments showed that for zones close to saturation; beam-hardening leads to an overestimation of moisture content; while for a zone with a low water content; the X-ray radiography results without correction tend to underestimate it. After correction; the method showed a quantitative result close to that of the gravimetric method; and maintained a good stability in samples of different thickness. © 2024 Elsevier Ltd;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] New simple method of X-ray beam hardening correction for CT reconstruction
    Fang, Zheng
    Sun, Xiaomin
    Luo, Qingming
    Guangxue Xuebao/Acta Optica Sinica, 2007, 27 (02): : 302 - 306
  • [22] Simplified Statistical Image Reconstruction for X-ray CT With Beam-Hardening Artifact Compensation
    Abella, Monica
    Martinez, Cristobal
    Desco, Manuel
    Jose Vaquero, Juan
    Fessler, Jeffrey A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (01) : 111 - 118
  • [23] TOWARDS BEAM HARDENING CORRECTION FOR POLYCHROMATIC X-RAY CT
    Park, Hyoung Suk
    Gao, Hao
    Lee, Sung Min
    Seo, Jin Keun
    JOURNAL OF COMPUTATIONAL MATHEMATICS, 2016, 34 (06) : 671 - 682
  • [24] Beam hardening correction in polychromatic x-ray grating interferometry
    Yan, Aimin
    Wu, Xizeng
    Liu, Hong
    OPTICS EXPRESS, 2017, 25 (20): : 24690 - 24704
  • [25] X-ray beam hardening correction by minimising reprojection distance
    Kingston, Andrew M.
    Myers, Glenn R.
    Varslot, Trond K.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [26] A CBCT Beam-hardening Artifact Correction Method based on Optimal Filter Material Selection
    Liu, Chang
    Han, Yu
    Xi, XiaoQi
    Zhang, ZhiCun
    Li, Lei
    Yan, Bin
    2024 5TH INTERNATIONAL CONFERENCE ON MECHATRONICS TECHNOLOGY AND INTELLIGENT MANUFACTURING, ICMTIM 2024, 2024, : 248 - 251
  • [27] A comparison of beam-hardening artifacts in X-ray computerized tomography with gadolinium and iodine contrast agents
    Ruth, C
    Joseph, PM
    MEDICAL PHYSICS, 1995, 22 (12) : 1977 - 1982
  • [28] Pixel-wise beam-hardening correction for dark-field signal in X-ray dual-phase grating interferometry
    Tang, Ruizhi
    Organista, Caori
    Romano, Lucia
    van Hoorebeke, Luc
    Stampanoni, Marco
    Aelterman, Jan
    Boone, Matthieu n.
    OPTICS EXPRESS, 2023, 31 (24) : 40450 - 40468
  • [29] Analysis of X-Ray Beam Hardening Correction Method Relying on Cloud Computing Big Data
    Liu, Yanxiu
    Li, Ye
    Jiang, Sheng
    Zhao, Peng
    Qin, Xulei
    Liu, Yanyang
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2022, 2022
  • [30] Theoretical Beam Hardening Correction for Industrial X-ray Computed Tomography
    Ahmed, Osama M. H.
    Song, YuShou
    Xie, Zhaoyang
    JOURNAL OF ENGINEERING AND TECHNOLOGICAL SCIENCES, 2019, 51 (06): : 869 - 880