Beam-hardening correction method for quantifying moisture content in cement paste based on X-ray radiography

被引:0
|
作者
Wang, Xu [1 ]
Dong, Biqin [1 ]
Feng, Xing [1 ]
Hong, Shuxian [1 ]
Huang, Xiaoming [1 ]
机构
[1] Guangdong Provincial Key Laboratory of Durability for Marine Civil Engineering, Shenzhen University, Shenzhen,518060, China
关键词
The X-ray spectrum changes while traveling through specimen; and this phenomenon; known as the beam-hardening effect; breaks the linear relationship between the intensity variety on radiographs and material thickness. In the detection of water transport in cement-based materials; this effect leads to inaccurate results of the quantitative moisture distribution inside the sample; and it is difficult to eliminate this effect by gravimetric calibration. To solve this problem; this paper proposed a calibration strategy for the attenuation coefficient curve of cement-water two-phase specimens; and provided a heuristic mathematical model for fitting the 2D attenuation coefficient surface of cement paste specimens. The experiments showed that for zones close to saturation; beam-hardening leads to an overestimation of moisture content; while for a zone with a low water content; the X-ray radiography results without correction tend to underestimate it. After correction; the method showed a quantitative result close to that of the gravimetric method; and maintained a good stability in samples of different thickness. © 2024 Elsevier Ltd;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Beam-hardening correction method for quantifying moisture content in cement paste based on X-ray radiography
    Wang, Xu
    Dong, Biqin
    Feng, Xing
    Hong, Shuxian
    Huang, Xiaoming
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 421
  • [2] Beam-hardening in simulated X-ray tomography
    Ramakrishna, K.
    Muralidhar, K.
    Munshi, P.
    NDT & E INTERNATIONAL, 2006, 39 (06) : 449 - 457
  • [3] X-ray micro radiography using beam hardening correction
    Vavrik, Daniel
    Holy, Tomas
    Jakubek, Jan
    Pospisil, Stanislav
    Vykydal, Zdenek
    Dammer, Jiri
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2989 - 2992
  • [4] Reduction of beam-hardening artifacts in X-ray CT
    Menvielle, Nathalie
    Goussard, Yves
    Orban, Dominique
    Soulez, Gilles
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1865 - 1868
  • [5] Beam-hardening correction method based on original sinogram for X-CT
    Fu, J
    Lu, HN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 556 (01): : 379 - 385
  • [6] IDENTIFICATION OF NONLINEAR BEAM-HARDENING EFFECTS IN X-RAY TOMOGRAPHY
    Wang, Yiran
    SIAM JOURNAL ON MATHEMATICAL ANALYSIS, 2024, 56 (06) : 7290 - 7305
  • [7] Beam Hardening Correction Method for X-Ray Computed Tomography Based on Subsection Beam Hardening Curves
    Huang Kui-dong
    Zhang Ding-hua
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (09) : 2581 - 2584
  • [8] A beam hardening and dispersion correction for x-ray dark-field radiography
    Pelzer, Georg
    Anton, Gisela
    Horn, Florian
    Rieger, Jens
    Ritter, Andre
    Wandner, Johannes
    Weber, Thomas
    Michel, Thilo
    MEDICAL PHYSICS, 2016, 43 (06) : 2774 - 2779
  • [9] An iterative method for simultaneous reduction on beam-hardening and scatter artifacts in x-ray CT
    Xia, Dimeng
    Zhao, Shusen
    Zhang, Huitao
    Zhu, Yining
    Zhao, Xing
    Zhang, Peng
    PHYSICA SCRIPTA, 2023, 98 (04)
  • [10] Metal artifact reduction method based on a constrained beam-hardening estimator for polychromatic x-ray CT
    Hur, Jin
    Kim, Dongjoon
    Shin, Yeong-Gil
    Lee, Ho
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06):