Dose and dose rate dependence of the tissue sparing effect at ultra-high dose rate studied for proton and electron beams using the zebrafish embryo model

被引:7
|
作者
Horst, Felix [1 ,2 ,3 ]
Bodenstein, Elisabeth [1 ,2 ,3 ]
Brand, Michael [4 ,5 ]
Hans, Stefan [4 ,5 ]
Karsch, Leonhard [1 ,2 ,3 ]
Lessmann, Elisabeth [6 ]
Loeck, Steffen [2 ,3 ,7 ,8 ,9 ,10 ]
Schuerer, Michael [2 ,3 ,10 ,11 ,12 ,13 ,14 ]
Pawelke, Joerg [1 ,2 ,3 ]
Beyreuther, Elke [2 ,3 ,6 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, Inst Radiooncol OncoRay, Dresden, Germany
[2] Tech Univ Dresden, Fac Med, OncoRay Natl Ctr Radiat Res Oncol, Helmholtz Zentrum Dresden Rossendorf, Dresden, Germany
[3] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Helmholtz Zentrum Dresden Rossendorf, Dresden, Germany
[4] Tech Univ Dresden, Ctr Regenerat Therapies TU Dresden, Dresden, Germany
[5] Tech Univ Dresden, Cluster Excellence Phys Life, Dresden, Germany
[6] Helmholtz Zentrum Dresden Rossendorf, Inst Radiat Phys, Bautzener Landstr 400, D-01328 Dresden, Germany
[7] Tech Univ Dresden, Fac Med, Dept Radiotherapy & Radiat Oncol, Dresden, Germany
[8] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dresden, Germany
[9] German Canc Consortium DKTK, Partner Site Dresden, Heidelberg, Germany
[10] German Canc Res Ctr, Heidelberg, Germany
[11] Natl Ctr Tumor Dis Dresden NCT UCC, Heidelberg, Germany
[12] TUD Dresden Univ Technol, Fac Med, Dresden, Germany
[13] TUD Dresden Univ Technol, Univ Hosp Carl Gustav Carus, Dresden, Germany
[14] Helmholtz Zentrum Dresden Rossendorf HZDR, Dresden, Germany
关键词
Ultra -high dose rate (UHDR); Electrons; Protons; Flash effect; NTCP curves; Zebrafish embryo (ZFE); FLASH RADIATION-THERAPY; IRRADIATION;
D O I
10.1016/j.radonc.2024.110197
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A better characterization of the dependence of the tissue sparing effect at ultra-high dose rate (UHDR) on physical beam parameters (dose, dose rate, radiation quality) would be helpful towards a mechanistic understanding of the FLASH effect and for its broader clinical translation. To address this, a comprehensive study on the normal tissue sparing at UHDR using the zebrafish embryo (ZFE) model was conducted. Methods: One-day-old ZFE were irradiated over a wide dose range (15-95 Gy) in three different beams (proton entrance channel, proton spread out Bragg peak and 30 MeV electrons) at UHDR and reference dose rate. After irradiation the ZFE were incubated for 4 days and then analyzed for four different biological endpoints (pericardial edema, curved spine, embryo length and eye diameter). Results: Dose-effect curves were obtained and a sparing effect at UHDR was observed for all three beams. It was demonstrated that proton relative biological effectiveness and UHDR sparing are both relevant to predict the resulting dose response. Dose dependent FLASH modifying factors (FMF) for ZFE were found to be compatible with rodent data from the literature. It was found that the UHDR sparing effect saturates at doses above - 50 Gy with an FMF of - 0.7-0.8. A strong dose rate dependence of the tissue sparing effect in ZFE was observed. The magnitude of the maximum sparing effect was comparable for all studied biological endpoints. Conclusion: The ZFE model was shown to be a suitable pre-clinical high-throughput model for radiobiological studies on FLASH radiotherapy, providing results comparable to rodent models. This underlines the relevance of ZFE studies for FLASH radiotherapy research.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Radiobiological response to ultra-short pulsed megavoltage electron beams of ultra-high pulse dose rate
    Beyreuther, Elke
    Karsch, Leonhard
    Laschinsky, Lydia
    Lessmann, Elisabeth
    Naumburger, Doreen
    Oppelt, Melanie
    Richter, Christian
    Schuerer, Michael
    Woithe, Julia
    Pawelke, Joerg
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2015, 91 (08) : 643 - 652
  • [22] Absorbed-dose-to-water measurement using alanine in ultra-high-pulse-dose-rate electron beams
    Bourgouin, Alexandra
    Hackel, Thomas
    Marinelli, Marco
    Kranzer, Rafael
    Schueller, Andreas
    Kapsch, Ralf-Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (20):
  • [23] Silicon carbide detectors for dosimetry and monitoring of ultra-high dose rate beams
    Okpuwe, C.
    Amato, A.
    D'Amico, I.
    De Liso, V.
    De Napoli, M.
    Di Martino, F.
    Felici, G.
    Galluzzo, L.
    Medina, E.
    Vignati, A.
    Camarda, M.
    Romano, F.
    Milluzzo, G.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (03)
  • [24] Output Dependence On Dose Rate for Uniform Scanning Proton Beams
    Ramirez, E.
    Zheng, Y.
    MEDICAL PHYSICS, 2012, 39 (06) : 3706 - 3706
  • [25] Ultra-high dose-rate proton FLASH improves tumor control
    Shukla, Samriddhi
    Saha, Taniya
    Rama, Nihar
    Acharya, Anusha
    Le, Tien
    Bian, Fenghua
    Donovan, Johnny
    Tan, Lin Abigail
    Vatner, Ralph
    Kalinichenko, Vladimir
    Mascia, Anthony
    Perentesis, John P.
    Kalin, Tanya, V
    RADIOTHERAPY AND ONCOLOGY, 2023, 186
  • [26] Characterization of a ultra-high dose rate proton beam for preclinical experiments.
    Schwarz, M.
    Saini, J.
    Stappen, F. Vander
    Palmer, L.
    Zeng, J.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1572 - S1573
  • [27] Dose and dose rate measurements in proton beams using the luminescence of beryllium oxide
    Teichmann, T.
    Torres, M. J. Gonzalez
    van Goethem, M. J.
    van der Graaf, E. R.
    Henniger, J.
    Jahn, A.
    Kiewiet, H. H.
    Sommer, M.
    Ullrich, W.
    Weinhold, C.
    Kormoll, T.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [28] Investigation of a Simple Calorimeter Design for the Dosimetry of Ultra-High Pulse Dose Rate (FLASH) Electron Beams
    McEwen, M.
    Bourgouin, A.
    Schueller, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E294 - E294
  • [29] Characterization of Ultra-High-Dose Rate Electron Beams with ElectronFlash Linac
    Giuliano, Lucia
    Franciosini, Gaia
    Palumbo, Luigi
    Aggar, Lilia
    Dutreix, Marie
    Faillace, Luigi
    Favaudon, Vincent
    Felici, Giuseppe
    Galante, Federica
    Mostacci, Andrea
    Migliorati, Mauro
    Pacitti, Matteo
    Patriarca, Annalisa
    Heinrich, Sophie
    APPLIED SCIENCES-BASEL, 2023, 13 (01):
  • [30] Non-conventional Ultra-High Dose Rate (FLASH) Microbeam Radiotherapy Provides Superior Normal Tissue Sparing in Rat Lung Compared to Non-conventional Ultra-High Dose Rate (FLASH) Radiotherapy
    Wright, Michael D.
    Romanelli, Pantaleo
    Bravin, Alberto
    Le Duc, Geraldine
    Brauer-Krisch, Elke
    Requardt, Herwig
    Bartzsch, Stefan
    Hlushchuk, Ruslan
    Laissue, Jean-Albert
    Djonov, Valentin
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (11)