Multi-objective optimization of custom implant abutment design for enhanced bone remodeling in single-crown implants using 3D finite element analysis

被引:0
|
作者
Poovarodom, Pongsakorn [1 ,2 ]
Rungsiyakull, Chaiy [3 ]
Suriyawanakul, Jarupol [4 ]
Li, Qing [5 ]
Sasaki, Keiichi [6 ,7 ]
Yoda, Nobuhiro [7 ]
Rungsiyakull, Pimduen [1 ]
机构
[1] Chiang Mai Univ, Fac Dent, Dept Prosthodont, Chiang Mai 50200, Thailand
[2] Med Univ South Carolina, James B Edwards Coll Dent Med, Dept Reconstruct & Rehabil Sci, Res, Charleston, SC 29425 USA
[3] Chiang Mai Univ, Fac Engn, Dept Mech Engn, Chiang Mai 50200, Thailand
[4] Khon Kaen Univ, Fac Engn, Dept Mech Engn, Khon Kaen 40000, Thailand
[5] Univ Sydney, Fac Engn & IT, Sch Aerosp Mech & Mechatron Engn, Sydney, NSW 2037, Australia
[6] Miyagi Univ, Taiwa, Miyagi 9813298, Japan
[7] Tohoku Univ, Grad Sch Dent, Div Adv Prosthet Dent, Sendai, Miyagi 9808575, Japan
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
Optimization; Bone remodeling; Dental implant; Customized abutment; Finite element analysis; PLACEMENT DEPTH; CRESTAL BONE; DENTAL IMPLANTS; STRESS-ANALYSIS; SURFACE; SOFT; BEHAVIOR; RESTORATIONS; FAILURE; HEIGHT;
D O I
10.1038/s41598-024-66807-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The optimal configuration of a customized implant abutment is crucial for bone remodeling and is influenced by various design parameters. This study introduces an optimization process for designing two-piece zirconia dental implant abutments. The aim is to enhance bone remodeling, increase bone density in the peri-implant region, and reduce the risk of late implant failure. A 12-month bone remodeling algorithm subroutine in finite element analysis to optimize three parameters: implant placement depth, abutment taper degree, and gingival height of the titanium base abutment. The response surface analysis shows that implant placement depth and gingival height significantly impact bone density and uniformity. The taper degree has a smaller effect on bone remodeling. The optimization identified optimal values of 1.5 mm for depth, 35 degrees for taper, and 0.5 mm for gingival height. The optimum model significantly increased cortical bone density from 1.2 to 1.937 g/cm3 in 2 months, while the original model reached 1.91 g/cm3 in 11 months. The standard deviation of density showed more uniform bone apposition, with the optimum model showing values 2 to 6 times lower than the original over 12 months. The cancellous bone showed a similar trend. In conclusion, the depth and taper have a significant effect on bone remodeling. This optimized model significantly improves bone density uniformity.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Outcome of Implant Diameter and Length on the Distribution of Stress with Immediate Loaded Implants: A 3D Finite Element Analysis
    Kavitha, G.
    Sonkesriya, Subhash
    Kumar, Anil K.
    Almutairi, Faris Jaser
    Parmar, Pravin M.
    Parihar, Anuj Singh
    Sonkar, Tanu Priya
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1329 - S1331
  • [42] Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: A three-dimensional finite element analysis study
    Kaleli, Necati
    Sarac, Duygu
    Kulunk, Safak
    Ozturk, Ozgur
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03): : 437 - 445
  • [43] Finite element analysis of bone and implant stresses for customized 3D-printed orthopaedic implants in fracture fixation
    Yan, Lina
    Lim, Joel Louis
    Lee, Jun Wei
    Tia, Clement Shi Hao
    O'Neill, Gavin Kane
    Chong, Desmond Y. R.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2020, 58 (05) : 921 - 931
  • [44] Finite element analysis of bone and implant stresses for customized 3D-printed orthopaedic implants in fracture fixation
    Lina Yan
    Joel Louis Lim
    Jun Wei Lee
    Clement Shi Hao Tia
    Gavin Kane O’Neill
    Desmond Y.R. Chong
    Medical & Biological Engineering & Computing, 2020, 58 : 921 - 931
  • [45] Biomechanical Evaluation of the Effects of Implant Neck Wall Thickness and Abutment Screw Size: A 3D Nonlinear Finite Element Analysis
    Jeng, Ming-Dih
    Lin, Yang-Sung
    Lin, Chun-Li
    APPLIED SCIENCES-BASEL, 2020, 10 (10):
  • [46] Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    Tada, S
    Stegaroiu, R
    Kitamura, E
    Miyakawa, O
    Kusakari, H
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 357 - 368
  • [47] Multi-objective traffic signal optimization using 3D mesoscopic simulation and evolutionary algorithms
    Mihaita, Adriana Simona
    Dupont, Laurent
    Camargo, Mauricio
    SIMULATION MODELLING PRACTICE AND THEORY, 2018, 86 : 120 - 138
  • [48] Multi-objective optimization of 3D micro-fins using NSGA-II
    Soleimani, Shima
    Eckels, Steven
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 197
  • [49] Multi-objective Optimization of Shot-peening Parameters using Design of Experiments and Finite Element Simulation: A Statistical Model
    Hassanzadeh, Mahdi
    Torshizi, Seyed Ebrahim Moussavi
    JOURNAL OF APPLIED AND COMPUTATIONAL MECHANICS, 2022, 8 (03): : 838 - 852
  • [50] Optimal design of viscoelastic damping structures using layerwise finite element analysis and multi-objective genetic algorithm
    Xu, Chao
    Lin, Song
    Yang, Yunzhao
    COMPUTERS & STRUCTURES, 2015, 157 : 1 - 8