Influence of Heat Exchanging Tubes on Local Heat Transfer Coefficient in Fluidized Bed Reactor

被引:0
|
作者
Mohsen, Wasan A. [1 ]
Badday, Basma A. [1 ]
Ali, Jamal M. [1 ]
Sultan, Abbas J. [1 ]
Hasan, Zahraa W. [1 ]
机构
[1] Univ Technol Baghdad, Chem Engn Dept, Baghdad 10066, Iraq
关键词
multiphase flow system; immersed internals; heat transfer performance; fluidized bed reactor; silica sand; IMMERSED TUBE; HYDRODYNAMICS; FLOW; SIMULATION; PARTICLES;
D O I
10.1134/S0965544124010171
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
Fluidized bed reactors are widely used in a variety of chemical industrial processes for extremely exothermic reactions. But the performance of the reactor could be impacted if the exothermic reaction's heat isn't removed sufficiently. Understanding and analyzing the heat transfer mechanisms occurring in the reactor is crucial to improving the reactor's overall performance as well as the chemical process. The investigation was carried out in two stages) one tube heater, five internals equipped with one tube heater). In both stages, the heat transfer probe was moved to different places around and inside the center and the range of gas velocity was 0.2-0.48 m/s. A sophisticated heat transfer system was used to investigate locally and instantly how a bundle of vertical heat-exchanging tubes affects the heat transfer coefficient (HTC) in a gas solid fluidized bed. The experiments were conducted on 0.13 m inner diameter Plexiglas fluidized bed reactor by using silica sand as particles with size of 600 mu m and fixed packing height 35 cm. The heating element consists of solid brass shell, a heater and flux sensor. The heat transfer probe dimensions 12 mm diameter and 8 cm length. The thermocouples were 10 cm above distributer. The local heat transfer coefficient (LHTC) increase with increasing fluidizing velocity. There is a different behavior of HTC at various local position of tube heater in comparison with other different tubes position. When there are vertical internals present in the center, the HTC increases by 31% for different gas velocities. A comparison of local heat transfer coefficient with internal tube and without internal tube gives a reasonable result.
引用
收藏
页码:42 / 52
页数:11
相关论文
共 50 条
  • [31] Heat transfer characteristics of horizontal tubes in the dilute phase of the pressurized fluidized bed
    Bao, Zhongkai
    Huang, Yu
    Duan, Lunbo
    Duan, Yuanqiang
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 126
  • [32] Heat Transfer in a Fluidized Bed with Immersed Tubes Using Moist Coal Particles
    Dongwei Yang
    Hongling Yu
    Ruiyang Li
    Arabian Journal for Science and Engineering, 2018, 43 : 2263 - 2272
  • [33] Heat transfer between fluidized bed and horizontal bundle of tubes in a vertical channel
    Moawed M.A.
    Berbish N.S.
    Allam A.A.
    El-Shamy A.R.
    El-Shazly K.M.
    International Journal of Chemical Reactor Engineering, 2010, 8
  • [34] SURFACE TO FLUIDIZED BED HEAT TRANSFER
    BOTTERILL, JS
    DESAI, M
    CHEMICAL ENGINEERING SCIENCE, 1970, 25 (04) : 749 - +
  • [35] HEAT-TRANSFER TO HORIZONTAL TUBES IMMERSED IN A FLUIDIZED-BED COMBUSTOR
    GREWAL, NS
    MENART, J
    HAJICEK, DR
    ZOBECK, BJ
    POWDER TECHNOLOGY, 1987, 52 (02) : 149 - 159
  • [36] HEAT TRANSFER EFFICIENCY IN A FLUIDIZED BED
    DAYAN, Y
    KUPFERBE.A
    RESNICK, W
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1966, 44 (06): : 330 - &
  • [37] HEAT TRANSFER TO A LIQUID FLUIDIZED BED
    LEMLICH, R
    CALDAS, I
    AICHE JOURNAL, 1958, 4 (03) : 376 - 380
  • [38] Heat transfer in a circulating fluidized bed
    Yu S. Teplitskii
    Journal of Engineering Physics and Thermophysics, 1998, 71 (3) : 443 - 449
  • [39] INFLUENCE OF BUBBLE PASSAGE ON INSTANTANEOUS HEAT-TRANSFER COEFFICIENT WITH IMMERGED WALL IN FLUIDIZED-BED
    BERNIS, A
    VERGNES, F
    LEGOFF, P
    POWDER TECHNOLOGY, 1977, 18 (02) : 267 - 276
  • [40] The Impact of Bed Temperature on Heat Transfer Characteristic between Fluidized Bed and Vertical Rifled Tubes
    Blaszczuk, Artur
    Nowak, Wojciech
    JOURNAL OF THERMAL SCIENCE, 2016, 25 (05) : 476 - 483