Defining the Range of Calibration Burden: From Full Calibration to Calibration-Free

被引:0
|
作者
Rish, Adam J. [1 ]
Henson, Samuel [1 ]
Drennen, James K. [1 ,2 ]
Anderson, Carl A. [1 ,2 ]
机构
[1] Duquesne Univ, Grad Sch Pharmaceut Sci, 600 Forbes Ave, Pittsburgh, PA 15282 USA
[2] Duquesne Univ, Duquesne Ctr Pharmaceut Technol, 600 Forbes Ave, Pittsburgh, PA 15282 USA
关键词
Calibration burden; Calibration-free; Calibration design; Chemometrics; Process analytical technology (PAT); INFRARED-SPECTROSCOPY; DESIGN;
D O I
10.1007/s12247-024-09839-5
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The expansion of spectroscopic process analytical technology (PAT) within the pharmaceutical industry requires chemometric models to enable spectral interpretation. However, calibration of chemometric models often require an intense time, material, and financial burden which may discourage PAT deployment. The advancement of modeling strategies that reduce this calibration burden necessitates consistent terminology for describing model inputs and overall calibration burden throughout chemometric literature. The goal of this article is to define levels of calibration burden by clarifying dataset classifications and model inputs during PAT method development. The scope of this work is specific to calibration of chemometric models incorporated in PAT methods. Harmonizing the language used in the field of chemometrics to describe calibration burden benefits both pharmaceutical manufacturers and regulatory agencies.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Calibration-free wavelength modulation absorption spectrum of gas
    Li Ning
    Weng Chun-Sheng
    [J]. ACTA PHYSICA SINICA, 2011, 60 (07)
  • [32] A Novel Calibration-Free Remote Antenna Impedance Measurement
    Hosseini-Fahraji, Ali
    Manteghi, Majid
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2022, 70 (12) : 12212 - 12220
  • [33] Calibration-free retrieval of density information from computed tomography data
    Moonen, Peter
    Dhaene, Jelle
    Van den Bulcke, Jan
    Boone, Matthieu N.
    Van Hoorebeke, Luc
    [J]. PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2022, 76 : 377 - 384
  • [34] Transmission Line Voltage Calibration-Free Measurement Method
    Yang, Le
    Long, Wei
    Zhang, Wenbin
    Yan, Peiwu
    Zhou, Yu
    Li, Jiang
    [J]. ELECTRONICS, 2023, 12 (04)
  • [35] On calibration-free methods in segmentation of cDNA microarray images
    Vesanen, P
    Tiainen, M
    Yli-Harja, O
    [J]. IMAGE PROCESSING: ALGORITHMS AND SYSTEMS, 2002, 4667 : 291 - 302
  • [36] Calibration-Free Multi-view Crowd Counting
    Zhang, Qi
    Chan, Antoni B.
    [J]. COMPUTER VISION, ECCV 2022, PT IX, 2022, 13669 : 227 - 244
  • [37] A simple calibration-free method of complex permittivity extraction
    Kurdjumov, S.
    Filonov, D.
    Kretov, E.
    Ivanov, V.
    Ginzburg, P.
    [J]. METANANO 2019, 2020, 1461
  • [38] CALIBRATION-FREE MERCURY STRAIN-GAUGE PLETHYSMOGRAPH
    MICHAUX, B
    VANHOUTTE, JJ
    JAFFRIN, MY
    FONTENIER, G
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (04) : 539 - 542
  • [39] Towards calibration-free in situ chemical sensors.
    Baehr, MM
    DeGrandpre, MD
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U884 - U884
  • [40] Calibration-Free Nanopore Digital Counting of Single Molecules
    Nouri, Reza
    Tang, Zifan
    Guan, Weihua
    [J]. ANALYTICAL CHEMISTRY, 2019, 91 (17) : 11178 - 11184