Simulation of Random Deformable Motion in Soft-Tissue Cone-Beam CT with Learned Models

被引:0
|
作者
Hu, Y. [1 ]
Huang, H. [2 ]
Siewerdsen, J.H. [1 ,2 ]
Zbijewski, W. [2 ]
Unberath, M. [1 ]
Weiss, C.R. [3 ]
Sisniega, A. [2 ]
机构
[1] Dept. of Computer Science, Johns Hopkins University, Baltimore,MD, United States
[2] Dept of Biomedical Engineering, Johns Hopkins University, Baltimore,MD, United States
[3] Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore,MD, United States
关键词
Compendex;
D O I
7th International Conference on Image Formation in X-Ray Computed Tomography
中图分类号
学科分类号
摘要
Motion compensation
引用
收藏
相关论文
共 50 条
  • [41] Cone-Beam CT Reconstruction with Gravity-Induced Motion
    Shieh, C.
    Barber, J.
    Counter, W.
    Sykes, J.
    Bennett, P.
    Heng, S.
    White, P.
    Downes, S.
    Jackson, M.
    Keall, P.
    Feain, I.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [42] Clinical study of soft-tissue contrast resolution in cone-beam CT of the head using multi-resolution PWLS with multi-motion correction and an electronic noise model
    Wu, P.
    Sisniega, A.
    Stayman, J. W.
    Zbijewski, W.
    Foos, D.
    Wang, X.
    Aygun, N.
    Stevens, R.
    Siewerdsen, J. H.
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [43] Effects of cone-beam CT noise and cupping artifacts on deformable image registration
    Murphy, M.
    Lu, L.
    Crimaldi, A.
    Cuttino, L.
    Shield, C.
    Keall, P.
    Siebers, J.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 1996 - 1996
  • [44] Cone-Beam Angle Dependency of 3D Models Computed from Cone-Beam CT Images
    Cho, Myung Hye
    Hegazy, Mohamed A. A.
    Cho, Min Hyoung
    Lee, Soo Yeol
    SENSORS, 2022, 22 (03)
  • [45] The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors
    Siewerdsen, JH
    Moseley, DJ
    Bakhtiar, B
    Richard, S
    Jaffray, DA
    MEDICAL PHYSICS, 2004, 31 (12) : 3506 - 3520
  • [46] Converting Cone-Beam CT to In-Room Conventional CT by a Deformable Image Registration Method
    Zhang, Y.
    Yang, J.
    Zhang, L.
    Dong, L.
    MEDICAL PHYSICS, 2009, 36 (06) : 2477 - +
  • [47] Orthodontic soft-tissue parameters: A comparison of cone-beam computed tomography and the 3dMD imaging system
    Metzger, Tasha E.
    Kula, Katherine S.
    Eckert, George J.
    Ghoneima, Ahmed A.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (05) : 672 - 681
  • [48] Deformable planning CT to cone-beam CT image registration in head-and-neck cancer
    Hou, Jidong
    Guerrero, Mariana
    Chen, Wenjuan
    D'Souza, Warren D.
    MEDICAL PHYSICS, 2011, 38 (04) : 2088 - 2094
  • [49] Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach
    Nithiananthan, Sajendra
    Schafer, Sebastian
    Uneri, Ali
    Mirota, Daniel J.
    Stayman, J. Webster
    Zbijewski, Wojciech
    Brock, Kristy K.
    Daly, Michael J.
    Chan, Harley
    Irish, Jonathan C.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2011, 38 (04) : 1785 - 1798
  • [50] A Hybrid Deformable Registration Method between Helical CT and Cone-Beam CT for Prostate Patient
    Qin, A.
    Liang, J.
    Yan, D.
    MEDICAL PHYSICS, 2010, 37 (06)