Simulation of acquisition shifts in T2 weighted fluid-attenuated inversion recovery magnetic resonance images to stress test artificial intelligence segmentation networks

被引:0
|
作者
Posselt, Christiane [1 ]
Avci, Mehmet Yigit [2 ]
Yigitsoy, Mehmet [2 ]
Schuenke, Patrick [3 ,4 ]
Kolbitsch, Christoph [3 ,4 ]
Schaeffter, Tobias [3 ,4 ,5 ]
Remmele, Stefanie [1 ]
机构
[1] Univ Appl Sci, Fac Elect & Ind Engn, Landshut, Germany
[2] Deepc GmbH, Munich, Germany
[3] Phys Tech Bundesanstalt PTB, Braunschweig, Germany
[4] Phys Tech Bundesanstalt PTB, Berlin, Germany
[5] Tech Univ Berlin, Dept Med Engn, Berlin, Germany
关键词
magnetic resonance image simulation; artificial intelligence validation; magnetic resonance imaging sequence; multiple sclerosis lesion segmentation; T2w fluid attenuated inversion recovery; WHITE-MATTER; MRI; RELAXATION; SEQUENCES; ARTIFACTS; INCREASE; FLAIR;
D O I
10.1117/1.JMI.11.2.024013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To provide a simulation framework for routine neuroimaging test data, which allows for "stress testing" of deep segmentation networks against acquisition shifts that commonly occur in clinical practice for T2 weighted (T2w) fluid-attenuated inversion recovery magnetic resonance imaging protocols. Approach: The approach simulates "acquisition shift derivatives" of MR images based on MR signal equations. Experiments comprise the validation of the simulated images by real MR scans and example stress tests on state-of-the-art multiple sclerosis lesion segmentation networks to explore a generic model function to describe the F1 score in dependence of the contrast-affecting sequence parameters echo time (TE) and inversion time (TI). Results: The differences between real and simulated images range up to 19% in gray and white matter for extreme parameter settings. For the segmentation networks under test, the F1 score dependency on TE and TI can be well described by quadratic model functions (R-2 > 0.9). The coefficients of the model functions indicate that changes of TE have more influence on the model performance than TI. Conclusions: We show that these deviations are in the range of values as may be caused by erroneous or individual differences in relaxation times as described by literature. The coefficients of the F1 model function allow for a quantitative comparison of the influences of TE and TI. Limitations arise mainly from tissues with a low baseline signal (like cerebrospinal fluid) and when the protocol contains contrast-affecting measures that cannot be modeled due to missing information in the DICOM header. (c) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Detection of Brain Metastases by 3-Dimensional Magnetic Resonance Imaging at 3 T: Comparison Between T1-Weighted Volume Isotropic Turbo Spin Echo Acquisition and 3-Dimensional T1-Weighted Fluid-Attenuated Inversion Recovery Imaging
    Yoshida, Atsushi
    Tha, Khin Khin
    Fujima, Noriyuki
    Zaitsu, Yuri
    Yoshida, Daisuke
    Tsukahara, Akiko
    Onodera, Shunsuke
    Shirato, Hiroki
    Terae, Satoshi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) : 84 - 90
  • [42] Multiple sclerosis lesion detect in the brain: A comparison of fast fluid-attenuated inversion recovery and conventional T2-weighted dual spin echo
    GawneCain, ML
    ORiordan, JI
    Thompson, AJ
    Moseley, IF
    Miller, DH
    NEUROLOGY, 1997, 49 (02) : 364 - 370
  • [43] Accuracy for detection of simulated lesions: Comparison of fluid-attenuated inversion-recovery, proton density-weighted, and T2-weighted synthetic brain MR imaging
    Herskovits, EH
    Itoh, R
    Melhem, ER
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) : 1313 - 1318
  • [44] T2 relaxation measurements in X-linked adrenoleukodystrophy performed using dual-echo fast fluid-attenuated inversion recovery MR imaging
    Melhem, ER
    Gotwald, TF
    Itoh, R
    Zinreich, SJ
    Moser, HW
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (04) : 773 - 776
  • [45] T1-weighted Fluid Attenuated Inversion Recovery (FLAIR) pulse sequences: Use and limitations in magnetic resonance brain and spinal cord studies
    Aprile, I
    Muti, M
    Bartolini, N
    Zenoni, A
    Tazza, G
    Principi, M
    Italiani, M
    Ottaviano, P
    RIVISTA DI NEURORADIOLOGIA, 2001, 14 (03): : 301 - 308
  • [46] Transthyretin-related familial amyloid polyneuropathy: Evaluation of CSF enhancement on serial T1-weighted and fluid-attenuated inversion recovery images following intravenous contrast administration
    Hirai, T
    Ando, Y
    Yamura, M
    Kitajima, M
    Hayashida, Y
    Korogi, Y
    Yamashita, T
    Yamashita, Y
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (08) : 2043 - 2048
  • [47] Comparison of T2-weighted and fluid-attenuated inversion-recovery fast spin-echo MR sequences in intracerebral AIDS-associated disease
    Thurnher, MM
    Thumher, SA
    Fleischmann, D
    Steuer, A
    Rieger, A
    Helbich, T
    Trattnig, S
    Schindler, E
    Hittmair, K
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (09) : 1601 - 1609
  • [48] Supratentorial Meningioma Consistency Prediction Utilizing Tumor to Cerebellar Peduncle Intensity on T1 and T2-Weighted and Fluid Attenuated Inversion Recovery Magnetic Resonance Imaging Sequences
    Rabiee, Shervin
    Kankam, Samuel Berchi
    Shafizadeh, Milad
    Ahmadi, Maryam
    Khoshnevisan, Alireza
    Hashemi, Amirpajman
    WORLD NEUROSURGERY, 2023, 170 : E180 - E188
  • [49] Fully convolutional networks (FCNs)-based segmentation method for colorectal tumors on T2-weighted magnetic resonance images
    Junming Jian
    Fei Xiong
    Wei Xia
    Rui Zhang
    Jinhui Gu
    Xiaodong Wu
    Xiaochun Meng
    Xin Gao
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 393 - 401
  • [50] Fully convolutional networks (FCNs)-based segmentation method for colorectal tumors on T2-weighted magnetic resonance images
    Jian, Junming
    Xiong, Fei
    Xia, Wei
    Zhang, Rui
    Gu, Jinhui
    Wu, Xiaodong
    Meng, Xiaochun
    Gao, Xin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (02) : 393 - 401