Simulation of acquisition shifts in T2 weighted fluid-attenuated inversion recovery magnetic resonance images to stress test artificial intelligence segmentation networks

被引:0
|
作者
Posselt, Christiane [1 ]
Avci, Mehmet Yigit [2 ]
Yigitsoy, Mehmet [2 ]
Schuenke, Patrick [3 ,4 ]
Kolbitsch, Christoph [3 ,4 ]
Schaeffter, Tobias [3 ,4 ,5 ]
Remmele, Stefanie [1 ]
机构
[1] Univ Appl Sci, Fac Elect & Ind Engn, Landshut, Germany
[2] Deepc GmbH, Munich, Germany
[3] Phys Tech Bundesanstalt PTB, Braunschweig, Germany
[4] Phys Tech Bundesanstalt PTB, Berlin, Germany
[5] Tech Univ Berlin, Dept Med Engn, Berlin, Germany
关键词
magnetic resonance image simulation; artificial intelligence validation; magnetic resonance imaging sequence; multiple sclerosis lesion segmentation; T2w fluid attenuated inversion recovery; WHITE-MATTER; MRI; RELAXATION; SEQUENCES; ARTIFACTS; INCREASE; FLAIR;
D O I
10.1117/1.JMI.11.2.024013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To provide a simulation framework for routine neuroimaging test data, which allows for "stress testing" of deep segmentation networks against acquisition shifts that commonly occur in clinical practice for T2 weighted (T2w) fluid-attenuated inversion recovery magnetic resonance imaging protocols. Approach: The approach simulates "acquisition shift derivatives" of MR images based on MR signal equations. Experiments comprise the validation of the simulated images by real MR scans and example stress tests on state-of-the-art multiple sclerosis lesion segmentation networks to explore a generic model function to describe the F1 score in dependence of the contrast-affecting sequence parameters echo time (TE) and inversion time (TI). Results: The differences between real and simulated images range up to 19% in gray and white matter for extreme parameter settings. For the segmentation networks under test, the F1 score dependency on TE and TI can be well described by quadratic model functions (R-2 > 0.9). The coefficients of the model functions indicate that changes of TE have more influence on the model performance than TI. Conclusions: We show that these deviations are in the range of values as may be caused by erroneous or individual differences in relaxation times as described by literature. The coefficients of the F1 model function allow for a quantitative comparison of the influences of TE and TI. Limitations arise mainly from tissues with a low baseline signal (like cerebrospinal fluid) and when the protocol contains contrast-affecting measures that cannot be modeled due to missing information in the DICOM header. (c) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Brain White Matter Hyperintensity Lesion Characterization in T2 Fluid-Attenuated Inversion Recovery Magnetic Resonance Images: Shape, Texture, and Potential Growth
    Gwo, Chih-Ying
    Zhu, David C.
    Zhang, Rong
    FRONTIERS IN NEUROSCIENCE, 2019, 13
  • [2] Analysis of elements in a minimal amount of temporomandibular joint fluid on fluid-attenuated inversion recovery magnetic resonance images
    Hanyuda, Hitoshi
    Otonari-Yamamoto, Mika
    Imoto, Kenichi
    Sakamoto, Junichiro
    Kodama, Sayaka
    Kamio, Takashi
    Sano, Tsukasa
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 115 (01): : 114 - 120
  • [3] Hyperintensity of Cerebrospinal Fluid on T2-Weighted Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Caused by High Inspired Oxygen Fraction
    Moioli, Melania
    Levionnois, Olivier
    Stein, Veronika M.
    Schupbach, Gertraud
    Schmidhalter, Marta
    Schweizer-Gorgas, Daniela
    FRONTIERS IN VETERINARY SCIENCE, 2017, 4
  • [4] T2 Fluid-Attenuated Inversion Recovery Imaging of Uveal Melanomas and Other Ocular Pathology
    Damento, Gena M.
    Koeller, Kelly K.
    Salomao, Diva R.
    Pulido, Jose S.
    OCULAR ONCOLOGY AND PATHOLOGY, 2016, 2 (04) : 251 - 261
  • [5] FASCINATE:: A pulse sequence for simultaneous acquisition of T2-weighted and fluid-attenuated images
    Takeo, K
    Ishikawa, A
    Okazaki, M
    Kohno, S
    Shimizu, K
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 205 - 211
  • [6] Potential of fluid-attenuated inversion recovery (FLAIR) in identification of temporomandibular joint effusion compared with T2-weighted images
    Imoto, Kenichi
    Otonari-Yamamoto, Mika
    Nishikawa, Keiichi
    Sano, Tsukasa
    Yamamoto, Aya
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (02): : 243 - 248
  • [7] Comparison of fluid-attenuated in-version recovery and T2-weighted magnetic resonance images in dogs and cats with suspected brain disease
    Benigni, L
    Lamb, CR
    VETERINARY RADIOLOGY & ULTRASOUND, 2005, 46 (04) : 287 - 292
  • [8] MR fluid-attenuated inversion recovery imaging as routine brain T2-weighted imaging
    Arakia, Y
    Ashikaga, R
    Fujii, K
    Nishimura, Y
    Ueda, J
    Fujita, N
    EUROPEAN JOURNAL OF RADIOLOGY, 1999, 32 (02) : 136 - 143
  • [9] Clinical usefulness of T2-weighted fluid-attenuated inversion recovery MR imaging of the CNS
    Adams, JG
    Melhem, ER
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (02) : 529 - 536
  • [10] Diffusion-weighted and fluid-attenuated inversion recovery magnetic resonance imaging as sensitive and early indicators of hippocampal injury
    Golomb, MR
    Lev, MH
    LeSueur, LL
    Rosenberger, PB
    ANNALS OF NEUROLOGY, 1998, 44 (03) : 549 - 549