Practical calculation method for the overall stability of non-sway frames considering the inter-story interaction

被引:0
|
作者
Lan S. [1 ]
Zhou D. [2 ]
Cheng X. [1 ]
Wang C. [1 ]
机构
[1] College of Architecture and Civil Engineering, Kunming University, Kunming
[2] Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming
来源
Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University | 2023年 / 44卷 / 03期
关键词
characteristic structural unit; critical bearing capacity; layer support coefficient; load factor; non-sway frames; overall stability; surplus stiffness coefficient; the effective length ratio;
D O I
10.11990/jheu.202111023
中图分类号
学科分类号
摘要
In view of the inconvenience of determining the overall stability of non-sway frames using the standard calculation length method for each component checking and not considering the mutual support between the same-layer columns and the insufficient inter-story interaction, this study first explores the non-sway frames of support laws of the mutual support between the same-layer columns and inter-story interaction, deriving the critical stiffness ratio coefficient of non-sway frames based on the spring-swinging column model and structure conversion method. Then, the coefficient is used to determine the structural-layer load factor by analyzing the characteristic structural elements of non-sway frames, the surplus coefficient of the layer stiffness that characterizes the surplus degree of the layer stiffness of non-sway frames, and the layer support coefficient that characterizes the inter-story support effect. Finally, the calculation formula that can directly calculate the overall stability bearing capacity of non-sway frames is obtained through the axial force weighted average method. This formula can quantitatively calculate the degree of mutual support between floors of non-sway frames and avoid the unreasonable design caused by the standard calculation length method, which may be caused by not considering the two support functions. This method can be used for engineering design and theoretical calculation. © 2023 Editorial Board of Journal of Harbin Engineering. All rights reserved.
引用
收藏
页码:450 / 457
页数:7
相关论文
共 21 条
  • [11] ZHANG Hao, SU Mingzhou, CHENG Qianqian, Et al., Stability capacity of single-story non-sway frame with uniform beam loading, Progress in steel building structures, 21, 4, pp. 94-102, (2019)
  • [12] LAN Shuwei, ZHOU Donghua, SHUANG Chao, Et al., Practical calculation method for the critical bearing capacity of sway frame, Journal of vibration and shock, 38, 11, pp. 180-186, (2019)
  • [13] HAO Jiping, TIAN Weifeng, WANG Xiantie, Simple calculation method for overall stability of multi-story sway frame, Journal of building structures, 32, 11, pp. 183-188, (2011)
  • [14] LI Quanwang, ZOU Aming, ZHANG Hao, A simplified method for stability analysis of multi-story frames considering vertical interactions between stories[J], Advances in structural engineering, 19, 4, pp. 599-610, (2016)
  • [15] SLIMANI A, AMMARI F, ADMAN R., The effective length factor of columns in unsymmetrical frames asymmetrically loaded, Asian journal of civil engineering, 19, 4, pp. 487-499, (2018)
  • [16] KINDMANN ROLF, Stahlbau,Teil2: stabilität und theorie ll. ordnung, pp. 67-97, (2008)
  • [17] 铁摩辛柯 S P, pp. 49-66, (1956)
  • [18] HAO Jiping, TIAN Weifeng, WANG Xiantie, Simples calculation method for overall stability of multi-story sway fram, Journal of building structures, 32, 11, pp. 183-188, (2011)
  • [19] JI Yuan, TONG Gengshu, SHI Zuyuan, Critical load of frames with flexural-typed bracings and threshold stiffnesses for the bracings, Journal of Zhejiang University (engineering science), 36, 5, pp. 559-564, (2022)
  • [20] RAO Zhiying, TONG Genshu, Classification and stability design of multi-storey and high-rise steel structures, Building structure, 32, 5, pp. 7-11, (2002)