The influence of high-strength bolts stiffening on flange connection behaviour

被引:0
|
作者
Major I. [1 ]
Major M. [2 ]
Kuliński K. [1 ]
机构
[1] Department of Technical Mechanics and Engineering Graphics, Faculty of Civil Engineering, Częstochowa University of Technology, Akademicka 3, Częstochowa
[2] Department of Steel Structures and Building Materials, Faculty of Civil Engineering, Częstochowa University of Technology, Akademicka 3, Częstochowa
来源
Engineering Transactions | 2019年 / 67卷 / 02期
关键词
Flange connection; High-strength bolts; Structural analysis; Tightening torque; Torsion analysis;
D O I
10.24423/EngTrans.1006.20190405
中图分类号
学科分类号
摘要
Flange connections can commonly be seen in advertising board structures, which are subjected to wind loading. Depending on the structure’s geometry, additional torsion forces should be taken into account. In this paper the static behaviour of a flange connection with high-strength bolts under torsion load has been discussed. The numerical analysis concerns two cases: a flange connection subjected only to a high-strength bolts prestressing load and a flange connection subjected to both – bolts prestressing force and torsion moment. The stated boundary problem has been solved with the use of SolidWorks software. The obtained numerical results show good agreement with the analytical method. © 2019, Polish Academy of Sciences. All rights reserved.
引用
收藏
页码:199 / 211
页数:12
相关论文
共 50 条
  • [41] HIGH-STRENGTH BOLTS SUBJECT TO TENSION AND PRYING - CLOSURE
    NAIR, RS
    BIRKEMOE, PC
    MUNSE, WH
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1975, 101 (07): : 1608 - 1609
  • [42] Dimensional Tolerances and Length Determination of High-Strength Bolts
    Swanson, James A.
    Rassati, Gian Anima
    Larson, Chad M.
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2020, 57 (01): : 3 - 31
  • [43] About standard requirements to production of high-strength bolts
    Raber, L.M.
    Metallurgicheskaya i Gornorudnaya Promyshlennost, 2004, (06): : 59 - 60
  • [44] THE BEHAVIOR OF HIGH-STRENGTH GRADE 8.8 BOLTS IN FIRE
    KIRBY, BR
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1995, 33 (1-2) : 3 - 38
  • [45] Mechanical properties of high-strength bolts after fire
    Lou, Guo-Biao
    Wang, Rui
    Yu, Shan
    Li, Guo-Qiang
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2012, 165 (07) : 373 - 383
  • [46] Shear Capacity of High-Strength Bolts in Long Connections
    Tide, Raymond H. R.
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2017, 54 (01): : 61 - 67
  • [47] Specifying bolt length for high-strength bolts - Closure
    Carter, CJ
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1997, 34 (03): : 109 - 109
  • [48] Tensile behavior of novel column-to-column connection for modular steel construction using high-strength bolts
    Zhang, Yu-Jia
    Zhang, Lei
    Chen, Ya-Fei
    Tong, Gen-Shu
    Wang, Yan-Chao
    STRUCTURES, 2024, 65
  • [49] A Prying Action Force and Contact Force Estimation Model for a T-Stub Connection with High-Strength Bolts
    Yang, Jae-Guen
    Park, Jae-Ho
    Kim, Hyun-Kwang
    Back, Min-Chang
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2013, 12 (02) : 309 - 316
  • [50] Mechanical Properties of High-strength Bolts Material after High Temperature
    Huang B.
    Chen T.
    Jing H.
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2023, 31 (02): : 428 - 435