A Portable Polymer-based Sensor Platform for the Detection of Atrazine

被引:2
|
作者
Comnea-Stancu, Ionela Raluca [1 ]
van Staden, Jacobus Frederick [1 ]
Stefan-van Staden, Raluca-Ioana [1 ]
机构
[1] Natl Inst Res Electrochem & Condensed Matter, Lab Electrochem & PATLAB Bucharest, Splaiul Independentei 202, Bucharest, Romania
来源
CHEMISTRYSELECT | 2024年 / 9卷 / 17期
关键词
sensor platform; atrazine; electrochemical detection; polymer; water sample; ELECTRODES; HERBICIDES; EXPRESSION; REDUCTION;
D O I
10.1002/slct.202400757
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Despite being banned by the European Union (EU), Atrazine, a synthetic herbicide, was found in Europe's coastal waters. Given the widespread ban on atrazine in many countries, it is imperative to perform screenings to detect its presence in food and water samples, as it poses significant risks to both human health and aquatic ecosystems. This study presents the development of an innovative, simple, and cost-effective electrochemical sensing platform that comprises a portable system equipped with a poly-8-Amino-1-naphthol-3,6-disulfonic acid (8-ANDSA) customized carbon paste electrode (CPE). The poly-8 ANDSA/CPE was acquired using the process of electrochemical polymerization, utilizing cyclic voltammetry (CV) over the potential domain of -0.8 V to 1.8 V for 25 sweep cycles. The poly-8-ANDSA/CPE exhibited a linear relationship between the square wave voltammetric (SWV) peak current amplitude and ATZ concentration within 0.1-100 mu M. The limit of detection for ATZ was determined to be 30 nM. Spiked recovery results of 97.71 % to 102.73 % with RSD (%) values less than 5 % validated the method's applicability for atrazine detection from water samples. The favorable outcomes indicated that the portable system performs exceptionally well and validates the practicality of ATZ detection, facilitating on-site detection in actual water samples. This study presents the development of an innovative, simple, and cost-effective electrochemical sensing platform that comprises a portable system equipped with a poly-8 ANDSA/CPE. The poly-8-ANDSA/CPE exhibited a linear relationship between the square wave voltammetric (SWV) peak current amplitude and ATZ concentration within 0.1-100 mu M. The limit of detection for ATZ was determined to be 30 nM. Spiked recovery results of 97.71 % to 102.73 % with RSD (%) values less than 5 % validated the method's applicability for atrazine detection from water samples. image
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A Polymer-Based Ultrasensitive Metal Ion Sensor
    Liu, Xingqiang
    Zhou, Xin
    Shu, Xin
    Zhu, Jin
    MACROMOLECULES, 2009, 42 (20) : 7634 - 7637
  • [42] A Versatile Polymer-Based Platform for Intracellular Delivery of Macromolecules
    Kopytynski, Michal
    Chen, Siyuan
    Legg, Sandrine
    Minter, Ralph
    Chen, Rongjun
    ADVANCED THERAPEUTICS, 2020, 3 (02)
  • [43] Biomimetic polymer-based Ag nanocomposites as a antimicrobial platform
    Kung, Mei-Lang
    Lin, Pei-Ying
    Peng, Shi-Wei
    Wu, Deng-Chyang
    Wu, Wen-Jeng
    Yeh, Bi-Wen
    Tai, Ming-Hong
    Hung, Huey-Shan
    Hsieh, Shuchen
    APPLIED MATERIALS TODAY, 2016, 4 : 31 - 39
  • [44] Polymer-based packaging platform for hybrid microfluidic systems
    Krulevitch, P
    Bennett, W
    Hamilton, J
    Maghribi, M
    Rose, K
    BIOMEDICAL MICRODEVICES, 2002, 4 (04) : 301 - 308
  • [45] Polymer-Based Packaging Platform for Hybrid Microfluidic Systems
    P. Krulevitch
    W. Benett
    J. Hamilton
    M. Maghribi
    K. Rose
    Biomedical Microdevices, 2002, 4 : 301 - 308
  • [46] Polymer-based Virtual Sensor Array Leveraging Fringing Field Capacitance for VOC Detection
    Raj, Gian Carlo Antony
    Elnemr, Youssef Ezzat
    Munirathinam, Pavithra
    Birjis, Yumna
    Love, Calvin
    Emadi, Arezoo
    2023 IEEE SENSORS, 2023,
  • [47] Polymer-based Photonic Crystal Cavity Sensor for Optical Detection in the Visible Wavelength Region
    Maeno, Kenichi
    Axi, Shoma
    Sueyoshi, Kenji
    Hisamoto, Hideaki
    Endo, Tatsuro
    ANALYTICAL SCIENCES, 2016, 32 (01) : 117 - 120
  • [48] Polymer-based sensor arrays and multicomponent analysis for the detection of hazardous organic vapours in the environment
    Hierlemann, Andreas
    Weimar, Udo
    Kraus, Gerolf
    Schweizer-Berberich, Markus
    Goepel, Wolfgang
    Sensors and Actuators, B: Chemical, 1995, B26 (1 -3 pt 1) : 126 - 134
  • [49] Ultratrace Detection of Histamine Using a Molecularly-Imprinted Polymer-Based Voltammetric Sensor
    Akhoundian, Maedeh
    Ruter, Axel
    Shinde, Sudhirkumar
    SENSORS, 2017, 17 (03)
  • [50] A Molecularly Imprinted Polymer-Based Thermal Sensor for the Selective Detection of Melamine in Milk Samples
    Caldara, Manlio
    Lowdon, Joseph W.
    Royakkers, Jeroen
    Peeters, Marloes
    Cleij, Thomas J.
    Dilien, Hanne
    Eersels, Kasper
    van Grinsven, Bart
    FOODS, 2022, 11 (18)