IMPROVING MODEL CALIBRATION METHODS: A CASE STUDY APPLICATION OF INCORPORATING IEQ WITH ENERGY

被引:0
|
作者
Jain, Nishesh [1 ,2 ]
Burman, Esfand [1 ]
Mumovic, Dejan [1 ]
Davies, Michael [1 ]
机构
[1] UCL, UCL Inst Environm Design & Engn, London, England
[2] DesignBuilder Software Ltd, London, England
基金
“创新英国”项目; 英国工程与自然科学研究理事会;
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Calibrated building performance simulation models are useful in operational performance assessments. The current measurement and verification (M&V) protocols provide the statistical criteria to check model accuracy. However, they do not describe the criteria for uncertainty or the accuracy of dependent parameters such as zone environmental outputs. Mathematically, meeting just the validation criteria in a highly parameterized model and an under-determined search space can lead to unrealistic solutions. This paper explores ways to improve the quality of calibrated models and suggests a multi-level checking framework. This is implemented on a case study building. The paper describes the current industry standard of energy use validation as the lowest level of calibration with higher levels requiring further validation of disaggregated energy use, whilst meeting the indoor environment quality (IEQ) parameter validation criteria.
引用
收藏
页码:392 / 399
页数:8
相关论文
共 50 条
  • [31] Building energy model calibration: A review of the state of the art in approaches, methods, and tools
    Vera-Piazzini, Ofelia
    Scarpa, Massimiliano
    JOURNAL OF BUILDING ENGINEERING, 2024, 86
  • [32] Calibration and application of a continuum damage model on the simulation of stone masonry structures: Gondar church as a case study
    Silva, Bruno
    Guedes, Joao M.
    Arede, Antonio
    Costa, Anibal
    BULLETIN OF EARTHQUAKE ENGINEERING, 2012, 10 (01) : 211 - 234
  • [33] Application of Formal and Informal Bayesian Methods for Water Distribution Hydraulic Model Calibration
    Hutton, C. J.
    Kapelan, Z.
    Vamvakeridou-Lyroudia, L.
    Savic, D.
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2014, 140 (11)
  • [34] Calibration and application of a continuum damage model on the simulation of stone masonry structures: Gondar church as a case study
    Bruno Silva
    João M. Guedes
    António Arêde
    Aníbal Costa
    Bulletin of Earthquake Engineering, 2012, 10 : 211 - 234
  • [35] Application of microscopic simulation model calibration and validation procedure - Case study of coordinated actuated signal system
    Park, Byungkyu
    Won, Jongsun
    Yun, Ilsoo
    TRAFFIC SIGNAL SYSTEMS AND REGIONAL SYSTEMS MANAGEMENT 2006, 2006, (1978): : 113 - +
  • [36] Improving the Energy Performance of a Household Using Solar Energy: A Case Study
    Marza, Carmen
    Moldovan, Raluca
    Corsiuc, Georgiana
    Chisalita, Gelu
    ENERGIES, 2023, 16 (18)
  • [37] Improving Accuracy of a Network Model Basing on the Case Study of a Distributed System with a Mobile Application and an API
    Rzasa, Wojciech
    Jamro, Marcin
    Rzonca, Dariusz
    COMPUTER NETWORKS (CN 2017), 2017, 718 : 14 - 27
  • [38] Application of VSM for Improving the Medical Processes - Case Study
    Antosz, Katarzyna
    Augustyn, Aleksandra
    Jasiulewicz-Kaczmarek, Malgorzata
    ADVANCES IN PRODUCTION MANAGEMENT SYSTEMS: ARTIFICIAL INTELLIGENCE FOR SUSTAINABLE AND RESILIENT PRODUCTION SYSTEMS, APMS 2021, PT II, 2021, 631 : 413 - 421
  • [39] On the influence of several parameters in energy model calibration: the case of a historical building
    Pernetti, Roberta
    Prada, Alessandro
    Baggio, Paolo
    BUILDING SIMULATION APPLICATIONS (BSA 2013), 2013, : 263 - 272
  • [40] A methodology for improving wind energy production in low wind speed regions, with a case study application in Iraq
    Darwish, Abdul Salam
    Shaaban, Sabry
    Marsillac, Erika
    Mahmood, Nazar Muneam
    COMPUTERS & INDUSTRIAL ENGINEERING, 2019, 127 : 89 - 102