IMPROVING MODEL CALIBRATION METHODS: A CASE STUDY APPLICATION OF INCORPORATING IEQ WITH ENERGY

被引:0
|
作者
Jain, Nishesh [1 ,2 ]
Burman, Esfand [1 ]
Mumovic, Dejan [1 ]
Davies, Michael [1 ]
机构
[1] UCL, UCL Inst Environm Design & Engn, London, England
[2] DesignBuilder Software Ltd, London, England
基金
“创新英国”项目; 英国工程与自然科学研究理事会;
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Calibrated building performance simulation models are useful in operational performance assessments. The current measurement and verification (M&V) protocols provide the statistical criteria to check model accuracy. However, they do not describe the criteria for uncertainty or the accuracy of dependent parameters such as zone environmental outputs. Mathematically, meeting just the validation criteria in a highly parameterized model and an under-determined search space can lead to unrealistic solutions. This paper explores ways to improve the quality of calibrated models and suggests a multi-level checking framework. This is implemented on a case study building. The paper describes the current industry standard of energy use validation as the lowest level of calibration with higher levels requiring further validation of disaggregated energy use, whilst meeting the indoor environment quality (IEQ) parameter validation criteria.
引用
收藏
页码:392 / 399
页数:8
相关论文
共 50 条
  • [1] Improving hydrological simulations by incorporating GRACE data for model calibration
    Bai, Peng
    Liu, Xiaomang
    Liu, Changming
    JOURNAL OF HYDROLOGY, 2018, 557 : 291 - 304
  • [2] Improving energy use in schools: from IEQ towards energy-efficient planning—method and in-field application to two case studies
    Luísa Dias Pereira
    Francisco Bispo Lamas
    Manuel Gameiro da Silva
    Energy Efficiency, 2019, 12 : 1253 - 1277
  • [3] Improving energy use in schools: from IEQ towards energy-efficient planning-method and in-field application to two case studies
    Pereira, Luisa Dias
    Lamas, Francisco Bispo
    da Silva, Manuel Gameiro
    ENERGY EFFICIENCY, 2019, 12 (05) : 1253 - 1277
  • [4] Calibration and application of a sediment accumulation rate model - a case study
    Gelda, Rakesh K.
    Effler, Steven W.
    Matthews, David A.
    Owens, Emmet M.
    Hurteau, Craig A.
    Chapra, Steven C.
    Auer, Martin T.
    Gawde, Rasika K.
    Rowell, H. Chandler
    INLAND WATERS, 2012, 2 (01) : 23 - 36
  • [5] Application of Mobile-Internet-Based Occupancy Data in Building Energy Model Calibration: A Case Study
    Pang, Zhihong
    Xu, Peng
    O'Neill, Zheng
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [6] Improving rater calibration in aviation: A case study
    Holt, RW
    Hansberger, JT
    Boehm-Davis, DA
    INTERNATIONAL JOURNAL OF AVIATION PSYCHOLOGY, 2002, 12 (03): : 305 - 330
  • [7] Improving the efficiency of energy assessments with application of lean tools—a case study
    Raul J. Viera
    Zahra Sardoueinasab
    Jim Lee
    Energy Efficiency, 2019, 12 : 1717 - 1728
  • [8] Case Study: Improving Real-Time Stage Forecasting Muskingum Model by Incorporating the Rating Curve Model
    Barbetta, Silvia
    Moramarco, Tommaso
    Franchini, Marco
    Melone, Florisa
    Brocca, Luca
    Singh, Vijay P.
    JOURNAL OF HYDROLOGIC ENGINEERING, 2011, 16 (06) : 540 - 557
  • [9] METHODS FOR IMPROVING THE EFFICIENCY OF CALIBRATION OF A MODEL OF PHOSPHORUS CYCLING A LAKE ECOSYSTEM
    LOGA, M
    EKOLOGIA POLSKA-POLISH JOURNAL OF ECOLOGY, 1988, 36 (3-4): : 387 - 406
  • [10] Improving the efficiency of energy assessments with application of lean tools-a case study
    Viera, Raul J.
    Sardoueinasab, Zahra
    Lee, Jim
    ENERGY EFFICIENCY, 2019, 12 (07) : 1717 - 1728