Comparison of Heat Transfer and Friction in Pipes With Various Internal Roughness

被引:2
|
作者
Raoufi, Abdolreza [1 ]
Williams, Andrew D. [2 ]
Metcalfe, Craig [2 ]
Trudeau, Paul-Emile [2 ]
Brinkerhoff, Joshua [3 ]
Warwaruk, Lucas [1 ]
Ghaemi, Sina [1 ]
机构
[1] Univ Alberta, Dept Mech Engn, Edmonton, AB T6G 2R3, Canada
[2] Quantiam Technol Inc, Edmonton, AB T6N 1E6, Canada
[3] Univ British Columbia Okanagan, Fac Appl Sci, Sch Engn, Kelowna, BC V1V 1V7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
TURBULENT-FLOW; PRESSURE-DROP;
D O I
10.1115/1.4064495
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The heat transfer and friction factor of turbulent pipe flows with different internal roughness are experimentally investigated. Three types of roughness in forms of a mesh, hemispherical elements, and a coil are added to the interior of pipes with an inner diameter of 52.5 mm. The working fluid is air, and the Reynolds numbers vary from 20,000 to 90,000 in increments of 10,000. For investigating the heat transfer, the pipe wall is heated to 375 degrees C while the inlet air remains at the room temperature. The measurements show that the mesh-type roughness results in a maximum Nusselt number, Nu, increase of approximately 6%, the pipes with hemispherical roughness increased the Nu by a maximum amount of 30%, and the coil increased Nu by up to 60% compared with the smooth pipe. The maximum increase of friction factor is 40% for the pipes with mesh-type roughness, 30% for pipes with hemispherical roughness, and 67% for pipes with coil roughness. The experimental results indicate that adding hemispherical and coil roughness to the internal surface of the pipe can lead to a significant improvement in the rate of heat transfer while adding a mesh-type roughness can have marginal improvements and comes with a large frictional loss penalty. The analysis shows that the highest thermohydraulic performance is achieved using the hemispherical roughness elements.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] The effects of roughness types on friction factors and heat transfer in roughened rectangular duct
    Ahn, SW
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2001, 28 (07) : 933 - 942
  • [32] An investigation on friction factors and heat transfer coefficients in a rectangular duct with surface roughness
    Ahn, SW
    Son, KP
    KSME INTERNATIONAL JOURNAL, 2002, 16 (04): : 549 - 556
  • [33] A critical review on different roughness geometries and their effect on heat transfer and friction factor
    Patel, Sumer Singh
    Lanjewar, Atul
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (11) : 15391 - 15431
  • [34] Intensification of Heat Transfer in Pipes with Internal Screw-Type Ribbing.
    Lankevich, V.I.
    Perepelitsa, N.I.
    Sapankevich, A.P.
    Teploenergetika, 1980, (04): : 22 - 24
  • [35] Theoretical analysis of heat transfer and friction factor for turbulent flow of nanofluids through pipes
    Sharma, K. Viswanatha
    Azmi, Wan H.
    Kamal, Subhash
    Sarma, Pullela K.
    Vijayalakshmi, Bathula
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2016, 94 (03): : 565 - 575
  • [36] PIPES FOR HEAT-TRANSFER
    不详
    ENGINEERING MATERIALS AND DESIGN, 1972, 16 (03): : 50 - &
  • [37] On convective heat transfer in pipes
    Kochenov, I.S.
    Kochenov, S.I.
    Teploenergetika, 1992, (10): : 22 - 27
  • [38] Heat transfer in small pipes
    Blake, FC
    Peters, WA
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1924, 16 : 845 - 846
  • [39] A review on effect of various artificial roughness on heat transfer enhancement in a channel flow
    Panda, Sudharani
    Kumar, Rakesh
    JOURNAL OF THERMAL ENGINEERING, 2021, 7 (05): : 1267 - 1301
  • [40] EFFECT OF ARTIFICIAL ROUGHNESS ON HEAT-TRANSFER AND FRICTION FACTOR IN A SOLAR AIR HEATER
    PRASAD, BN
    SAINI, JS
    SOLAR ENERGY, 1988, 41 (06) : 555 - 560