Equipment energy-saving optimization method for central air-conditioning chilled water system

被引:0
|
作者
Yu, Junqi [1 ]
Gao, Zhikun [2 ]
Zhao, Anjun [1 ]
Hu, Qun [2 ]
机构
[1] School of Building Services Science and Engineering, Xi'an University of Architecture and Technology, Xi'an,710055, China
[2] College of Information and Control Engineering, Xi'an University of Architecture and Technology, Xi'an,710055, China
关键词
Artificial immune algorithms - Central air-conditioning - Central air-conditioning chilled water system - Chilled water systems - Control optimization - Energy-consumption - Exhaustive method - Operating parameters - Operating performance - Optimal operating performance;
D O I
10.11918/202103086
中图分类号
学科分类号
摘要
Due to the high-energy consumption of chilled water system in the central air-conditioning and the difficulty in dynamic adjustment for system equipment parameters with load changes, an adaptive parallel artificial immune algorithm combined with exhaustive method (EM-APAIA) was proposed to optimize equipment operating parameters under different loads, so as to reduce the operation energy consumption of chilled water system. First, the power consumption model of each piece of equipment in the system was established, and the minimum power consumption of all the equipment was taken as the optimal control objective of the chilled water system. Then, EM-APAIA was used to optimize the operation parameters of the chilled water supply temperature, the number of chilled water pumps, and the speed ratio. In the algorithm, the initialization method, migration operator, and mutation probability were improved, and the exhaustive method mechanism was introduced, enhancing its ability to optimize the equipment operating parameters for the chilled water system. Finally, a simulation experiment was carried out on an actual chilled water system of central air-conditioning. Results show that compared with the conventional setting, the total energy consumption of the system was reduced by 14. 8% after its equipment operating parameters were optimized by EM-APAIA. The algorithm not only achieved better control strategy than the comparison algorithms, but also exhibited fast convergence speed and strong stability, which can be better applied to the control optimization of the equipment in central air-conditioning chilled water system. © 2022 Harbin Institute of Technology. All rights reserved.
引用
收藏
页码:143 / 150
相关论文
共 50 条
  • [1] An Optimal Hybrid Control Method for Energy-Saving of Chilled Water System in Central Air Conditioning
    Zhang, Yan
    Chu, Xiaoli
    Liu, Yongqiang
    [J]. JOURNAL OF CONTROL SCIENCE AND ENGINEERING, 2018, 2018
  • [2] An Energy-Saving Control Strategy on Central Air-Conditioning System
    Sheng Xing 1
    [J]. Electricity, 2011, 22 (04) : 62 - 66
  • [3] A Group Control Method of Central Air-conditioning Chilled Water Pumps with the Aim of Energy Saving
    Li, Hai
    Shi, Jun
    Li, Ziwen
    Yang, Caidong
    Zhang, Yan
    Liang, Zhaowen
    Liu, Yongqiang
    [J]. 2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 4517 - 4524
  • [4] The Application of Fuzzy PID Control In The Energy Saving of Central Air-Conditioning Chilled Water System
    Ning, Yuguang
    Zong, Xuejun
    Hu, Zhigang
    Ge, Rui
    [J]. 2010 THE 3RD INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND INDUSTRIAL APPLICATION (PACIIA2010), VOL VII, 2010, : 17 - 20
  • [5] The Application of Fuzzy PID Control In The Energy Saving of Central Air-Conditioning Chilled Water System
    Ning, Yuguang
    Zong, Xuejun
    Hu, Zhigang
    Ge, Rui
    [J]. 2011 INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION AND INDUSTRIAL APPLICATION (ICIA2011), VOL II, 2011, : 17 - 20
  • [6] The Central Air-conditioning Energy-saving Control Technology
    Lei, Debao
    Tang, Zhonghua
    Zhao, Kai
    [J]. ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 2695 - +
  • [7] Study on chilled energy storage of air-conditioning system with energy saving
    Lin, Hu
    Li, Xin-hong
    Cheng, Peng-sheng
    Xu, Bu-gong
    [J]. ENERGY AND BUILDINGS, 2014, 79 : 41 - 46
  • [8] Discussion to energy-saving design of the air-conditioning system
    Qian, Wang
    Rui, Li
    [J]. SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3, 2013, 361-363 : 444 - 447
  • [9] Energy-saving Technique Targeting Chilled-water Air Conditioning Equipment in Data Centers
    Nakata, Tatsuya
    Kaneko, Shinichiro
    Yoshii, Ari
    Sekiguchi, Keisuke
    Yanagi, Masahide
    [J]. 2014 IEEE 36TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2014,
  • [10] Environmentally Friendly, Energy-saving Air-conditioning System
    Haneda, Tomoaki
    [J]. FUJITSU SCIENTIFIC & TECHNICAL JOURNAL, 2010, 46 (04): : 383 - 388